2924676 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2924676 Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3,
Phoenix Contact

Part#:2924676

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3,

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2924676 Phoenix Contact price in the box on the right side or send a quick quote.

2924676 Product Details

  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Degree of protection
    IP20 (not assessed by UL)
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Transmission Behavior
    1:1 to input signal
  • Max. current consumption
    < 100 mA (24 V / 20 mA)
  • Ambient temperature (operation)
    -20 °C ... 60 °C (Any mounting position)
  • Current input signal
    4 mA ... 20 mA
  • Signal output
    Current output
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Stripping length
    8 mm
  • Maximum temperature coefficient
    < 0.01 %/K
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Housing material
    PA 6.6-FR
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • Max. output voltage Uo
    25.2 V
  • Max. external capacitance Co
    820 nF
  • ATEX
     II (1) G [Ex ia Ga] IIC
  • DNV GL-Humidity
    B
  • Temperature
    B
  • EMC
    A
  • ECLASS 10.0.1
    27210120
  • ECLASS 9.0
    27210120
  • ETIM 7.0
    EC002653
  • UNSPSC 11
    39121008
  • Height
    116 mm
  • Maximum altitude
    ≤ 2000 m
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Output behavior in the event of an error
    < 3.6 mA (In the event of cable break at the input (as per NE 43))
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 16
  • Status display
    Green LED (supply voltage)
  • Interference emission
    EN 61000-6-4
  • Designation
    INMETRO
  • HART function
    Yes
  • Max. output power Po
    587 mW
  • Safety-related maximum voltage Um
    253 V AC (125 V DC)
  • Conformance
    CE-compliant, additionally EN 61326
  • DNV GL-Temperature
    B
  • Humidity
    B
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27210100
  • ETIM 4.0
    EC002653
  • UNSPSC 6.01
    30211506
  • Depth
    114.5 mm
  • Signal input
    Intrinsically safe
  • Underload/overload signal range
    0 mA ... 24 mA
  • Nominal supply voltage
    24 V DC
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Connection name
    Test socket
  • Step response (10-90%)
    < 1.3 ms (for 4 mA ... 20 mA step)
  • Overvoltage category
    II
  • Rated insulation voltage
    300 Vrms
  • Electrical isolation
    375 V (Peak value in accordance with IEC/EN 60079-11)
  • Additional text
    and EN 61326
  • IECEx
    [Ex ia Ga] IIC
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Certificate
    DNV 18.0140 X
  • ECLASS 4.0
    27210100
  • Width
    12.5 mm
  • Transmitter supply voltage
    > 16 V (at 20 mA)
  • Current output signal
    4 mA ... 20 mA (active)
  • Load/output load current output
    ≤ 450 Ω (20 mA)
  • Power dissipation
    < 1.4 W (at 24 V DC / 20 mA)
  • Max. diameter
    2.3 mm
  • No. of channels
    2
  • Degree of pollution
    2
  • Test voltage
    1.5 kV AC (50 Hz, 1 min.)
  • Group
    IIC
  • Max. external inductivity Lo
    100 µH
  • Maximum transmission error
    < 0.1 % (of final value)
  • Transmission error, typical
    < 0.05 % (of final value)
  • Color
    gray
  • Protocols supported
    HART
  • Max. output current Io
    93 mA
  • Standards/regulations
    GB 3626.20
  • UL, USA/Canada
    Class I Div 2; IS for Class I, II, III Div 1
  • DNV GL-EMC
    A
  • Vibration
    A
  • ECLASS 11.0
    27210120
  • ECLASS 6.0
    27210100
  • DNV GL-Vibration
    A
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27210120
  • UNSPSC 7.0901
    39121008
  • UNSPSC 21.0
    39121008
  • Identification
    [Ex ia Ga] IIC/IIB
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 4.1
    27210100
  • ETIM 6.0
    EC002653
  • UNSPSC 19.0
    39121008
  • UNSPSC 20.0
    39121008
  • Noise emission
    EN 61000-6-4
  • ECLASS 5.1
    27210100
  • UNSPSC 12.01
    39121008
  • UNSPSC 13.2
    39121008
  • UNSPSC 18.0
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo