2924278 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2924278 NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.
Phoenix Contact

Part#:2924278

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: NAMUR signal conditioner for operating proximity sensors and switches. The signals are transmitted to the control level via 2 transistor outputs (passive). Line fault detection, 3-way electrical isolation, SIL 2, Push-in connection.

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 2924278 Phoenix Contact price in the box on the right side or send a quick quote.

2924278 Product Details

  • UNSPSC 19.0
    39121008
  • Identification
    2
  • Temperature
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Certificate
    DNV GL TAA00000AG
  • ECLASS 4.1
    27210100
  • ECLASS 10.0.1
    27210121
  • ETIM 2.0
    EC001485
  • ETIM 6.0
    EC001485
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Additional text
    and EN 61326-1
  • Vibration
    A
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27210121
  • ECLASS 5.0
    27210100
  • ECLASS 7.0
    27210121
  • ETIM 4.0
    EC001485
  • UNSPSC 6.01
    30211506
  • UNSPSC 7.0901
    39121008
  • UNSPSC 21.0
    39121008
  • ECLASS 6.0
    27210100
  • ETIM 7.0
    EC001485
  • UNSPSC 12.01
    39121008
  • UNSPSC 18.0
    39121008
  • UNSPSC 20.0
    39121008
  • Humidity
    B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 4.0
    27210100
  • EMC
    B
  • ECLASS 5.1
    27210100
  • ECLASS 9.0
    27210121
  • ETIM 3.0
    EC001485
  • UNSPSC 11
    39121008
  • UNSPSC 13.2
    39121008
  • Width
    12.5 mm
  • Noise immunity
    EN 61000-6-2
  • Short-circuit current
    ~ 8 mA
  • Switching output
    2 transistor outputs, passive
  • Max. switching current
    50 mA (short-circuit-proof)
  • Nominal supply voltage
    24 V DC
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Conductor cross section AWG
    24 ... 16
  • Interference emission
    EN 61000-6-4
  • Test voltage
    1 kV AC (50 Hz, 1 min.)
  • Evaluation criterion
    A
  • Height
    116 mm
  • Degree of protection
    IP20 (not assessed by UL)
  • Switching points (attenuated)
    < 1.2 mA (blocking)
  • Line fault detection
    Break 0.05 mA < IIN < 0.35 mA
  • Min. contact current
    5 mA (short-circuit-proof)
  • Power consumption
    ≤ 800 mW
  • Status display
    Green LED (supply voltage)
  • Overvoltage category
    II
  • Color
    gray
  • Depth
    114.5 mm
  • Maximum altitude
    ≤ 2000 m
  • Non-load voltage
    ~ 8 V DC
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Switching hysteresis
    < 0.2 mA
  • Max. current consumption
    < 28 mA (24 V DC)
  • Power dissipation
    ≤ 800 mW
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -20 °C ... 60 °C (Any mounting position)
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Available input sources
    NAMUR proximity sensors (EN 60947-5-6)
  • Supply voltage range
    19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
  • Switching points (unattenuated)
    > 2.1 mA (conductive)
  • Switching frequency
    ≤ 5 kHz
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Degree of pollution
    2
  • Housing material
    PA 6.6-FR
  • Safety Integrity Level (SIL)
    2
  • Conformance
    CE-compliant, additionally EN 61326-1
  • Maximum switching voltage
    30 V DC
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Designation
    Safety Integrity Level (SIL, IEC 61508)
  • ATEX
     II 3 G Ex nA IIC T4 Gc X
  • DNV GL-Humidity
    B
  • DNV GL-EMC
    B
  • Minimum switching voltage
    3 V DC
  • Connection method
    Push-in connection
  • No. of channels
    1
  • Rated insulation voltage
    50 Vrms
  • Standards/regulations
    EN 61000-4-6
  • Noise emission
    EN 61000-6-4
  • DNV GL-Temperature
    B
  • UL, USA/Canada
    UL 508 Listed
  • Stripping length
    8 mm
  • Insulation
    Basic insulation in accordance with IEC/EN 61010-1
  • DNV GL-Vibration
    A

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo