2910125 Phoenix Contact DC/DC Converters
Part#:2910125
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 20
Nov 24, 2024
Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 48 V DC , output: 24 V DC / 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2910125 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight0.6 kg
- Electric strength, max. 60 V DC (60 s)
- Inrush current limitation typical 1 A
- Input fuse 10 A (slow-blow, internal)
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Dynamic Boost (IDyn.Boost) 10 A (5 s)
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Short-circuit-proof yes
- UIn > 0.8 x UInNom (LED off)
- Maximum contact load 24 V DC
- Time 590000 h
- Mains buffering typ. 18 ms (48 V DC)
- Type test (IEC/EN 60950-1) A 2 kV DC
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Production test C 0.5 kV DC
- Nominal output voltage (UN) 24 V DC
- Nominal output current (IN) 5 A
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
- System deviation, static < 1 % (change in load, static 10 % ... 90 %)
- Connection in parallel Yes, for redundancy and increased capacity
- Rise time < 1 s (UOUT (10 % ... 90 %))
- POut > 100 % (LED lights up yellow, output power > 240 W)
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Function Signal ground
- Voltage 1 kV
- Inrush current integral (I2t) < 0.2 A2s
- Production test B 2 kV DC
- Stripping length 8 mm
- Conductor cross section AWG 24 ... 16
- System deviation, input voltage change < 0.1 % (change in input voltage ±10 %)
- Residual ripple < 15 mVPP
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Digital 0 V DC
- Switch contact floating
- Input voltage range 29 V DC ... 57.6 V DC
- Switch-on time < 1 s
- Type test (IEC/EN 60950-1) B 4 kV DC
- Production test A 2 kV DC
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Typical current consumption 3.3 A (48 V DC)
- Typical response time 300 ms (from SLEEP MODE)
- Insulation voltage input/output 4 kV DC (type test)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test D 0.5 kV DC
- Connection method Push-in connection
- Static Boost (IStat.Boost) 6.25 A
- Magnetic circuit breaker tripping A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
- Feedback voltage resistance ≤ 35 V DC
- Connection labeling 3.4 +
- Signal option Output current
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Temperature 30 °C
- Degree of protection IP20
- Hood version Stainless steel X6Cr17
- Width with alternative assembly 122 mm
- Ambient temperature (start-up type tested) -40 °C
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- ECLASS 11.0 27210901
- Selective Fuse Breaking (ISFB) 30 A (15 ms)
- No-load proof yes
- Connection in series yes
- Types of signaling LED
- UOut > 0.9 x USet (LED lights up green)
- Reference potential to OUT1, OUT2, REM
- Output current 5 A
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Side element version Aluminum
- Depth with alternative assembly 39 mm
- Power dissipation SLEEP MODE < 1 W
- Degree of pollution 2
- Climatic class 3K3 (EN 60721)
- Standard designation Mains variation/undervoltage
- Designation Shipbuilding
- DNV GL noise radiation Class B
- Noise emission EN 55016
- Fast transients (burst) EN 61000-4-4
- Signal 2 kV (Test Level 3 - asymmetrical)
- Frequency 0 Hz
- Damped oscillating magnetic field EN 61000-4-10
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- MTBF (IEC 61709, SN 29500) > (25 °C)
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Width 36 mm
- Efficiency typ. 94 % (48 V DC)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Overvoltage category EN 61010-1 II
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
- EMC requirements for noise immunity EN 61000-6-1
- Standards/regulations EN 61000-4-29
- Identification ABS
- DNV GL conducted interference Class B
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- Input 1 kV (Test Level 3 - symmetrical)
- Surge voltage load (surge) EN 61000-4-5
- I/O/S asymmetrical
- Pulse-shape magnetic field EN 61000-4-9
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- ECLASS 9.0 27210901
- Main converter stage 50 kHz ... 420 kHz (Main converter stage)
- Height 130 mm
- Height with alternative assembly 130 mm
- Maximum power dissipation in no-load condition < 2 W
- Power loss nominal load max. < 8 W
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Overvoltage category EN 62477-1 III
- EMC requirements for noise emission EN 61000-6-3
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Conducted noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Frequency range 50 Hz ... 60 Hz
- Test field strength 100 A/m
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage dips EN 61000-4-29
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 7.0 EC002046
- Protection class Special with SELV input and output
- Depth 125 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- EMC requirements, power plant IEC 61850-3
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Additional text Test Level 2
- Contact discharge 8 kV (Test Level 4)
- Electrostatic discharge EN 61000-4-2
- Conducted interference EN 61000-4-6
- Power frequency magnetic field EN 61000-4-8
- Voltage dip 0 %
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27210901
- ETIM 6.0 EC002046
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$263.91
Stock:
20
Select Qty:
$263.91
$263.91 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨