2910125 Phoenix Contact DC/DC Converters

Phoenix Contact 2910125 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 48 V DC , output: 24 V DC / 5 A
Phoenix Contact

Part#:2910125

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 48 V DC , output: 24 V DC / 5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2910125 Phoenix Contact price in the box on the right side or send a quick quote.

2910125 Product Details

  • Electric strength, max.
    60 V DC (60 s)
  • Inrush current limitation typical
    1 A
  • Input fuse
    10 A (slow-blow, internal)
  • Conductor cross section solid
    0.2 mm² ... 1 mm²
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 1.5 mm²
  • Dynamic Boost (IDyn.Boost)
    10 A (5 s)
  • System deviation, dynamic
    < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • Short-circuit-proof
    yes
  • UIn
    > 0.8 x UInNom (LED off)
  • Maximum contact load
    24 V DC
  • Time
    590000 h
  • Mains buffering
    typ. 18 ms (48 V DC)
  • Type test (IEC/EN 60950-1) A
    2 kV DC
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Production test C
    0.5 kV DC
  • Nominal output voltage (UN)
    24 V DC
  • Nominal output current (IN)
    5 A
  • Setting range of the output voltage (USet)
    24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
  • System deviation, static
    < 1 % (change in load, static 10 % ... 90 %)
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • POut
    > 100 % (LED lights up yellow, output power > 240 W)
  • Analog
    4 mA ... 20 mA ±5 % (Load ≤400 Ω)
  • Function
    Signal ground
  • Voltage
    1 kV
  • Inrush current integral (I2t)
    < 0.2 A2s
  • Production test B
    2 kV DC
  • Stripping length
    8 mm
  • Conductor cross section AWG
    24 ... 16
  • System deviation, input voltage change
    < 0.1 % (change in input voltage ±10 %)
  • Residual ripple
    < 15 mVPP
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • Digital
    0 V DC
  • Switch contact
    floating
  • Input voltage range
    29 V DC ... 57.6 V DC
  • Switch-on time
    < 1 s
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Production test A
    2 kV DC
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.2 mm² ... 0.75 mm²
  • Typical current consumption
    3.3 A (48 V DC)
  • Typical response time
    300 ms (from SLEEP MODE)
  • Insulation voltage input/output
    4 kV DC (type test)
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Production test D
    0.5 kV DC
  • Connection method
    Push-in connection
  • Static Boost (IStat.Boost)
    6.25 A
  • Magnetic circuit breaker tripping
    A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
  • Feedback voltage resistance
    ≤ 35 V DC
  • Connection labeling
    3.4 +
  • Signal option
    Output current
  • Default
    Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
  • Temperature
    30 °C
  • Degree of protection
    IP20
  • Hood version
    Stainless steel X6Cr17
  • Width with alternative assembly
    122 mm
  • Weight
    0.6 kg
  • Ambient temperature (start-up type tested)
    -40 °C
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Input, output (test level 3)
    10 MHz (Test Level 2 - asymmetrical)
  • Signals (test level 1)
    100 kHz 1 MHz (Test Level 2 - symmetrical)
  • ECLASS 11.0
    27210901
  • Selective Fuse Breaking (ISFB)
    30 A (15 ms)
  • No-load proof
    yes
  • Connection in series
    yes
  • Types of signaling
    LED
  • UOut
    > 0.9 x USet (LED lights up green)
  • Reference potential
    to OUT1, OUT2, REM
  • Output current
    5 A
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Side element version
    Aluminum
  • Depth with alternative assembly
    39 mm
  • Power dissipation SLEEP MODE
    < 1 W
  • Degree of pollution
    2
  • Climatic class
    3K3 (EN 60721)
  • Standard designation
    Mains variation/undervoltage
  • Designation
    Shipbuilding
  • DNV GL noise radiation
    Class B
  • Noise emission
    EN 55016
  • Fast transients (burst)
    EN 61000-4-4
  • Signal
    2 kV (Test Level 3 - asymmetrical)
  • Frequency
    0 Hz
  • Damped oscillating magnetic field
    EN 61000-4-10
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Input, output (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • MTBF (IEC 61709, SN 29500)
    > (25 °C)
  • Auxiliary converter stage
    190 kHz ... 220 kHz (Auxiliary converter stage)
  • Width
    36 mm
  • Efficiency
    typ. 94 % (48 V DC)
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Overvoltage category EN 61010-1
    II
  • Vibration (operation)
    5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standards/regulations
    EN 61000-4-29
  • Identification
    ABS
  • DNV GL conducted interference
    Class B
  • Discharge in air
    15 kV (Test Level 4)
  • Comments
    Criterion A
  • Input
    1 kV (Test Level 3 - symmetrical)
  • Surge voltage load (surge)
    EN 61000-4-5
  • I/O/S
    asymmetrical
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Signals (test level 2)
    100 kHz 1 MHz (Test Level 2 - asymmetrical)
  • ECLASS 9.0
    27210901
  • Main converter stage
    50 kHz ... 420 kHz (Main converter stage)
  • Height
    130 mm
  • Height with alternative assembly
    130 mm
  • Maximum power dissipation in no-load condition
    < 2 W
  • Power loss nominal load max.
    < 8 W
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Overvoltage category EN 62477-1
    III
  • EMC requirements for noise emission
    EN 61000-6-3
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Conducted noise emission
    EN 55016
  • Electromagnetic HF field
    EN 61000-4-3
  • Frequency range
    50 Hz ... 60 Hz
  • Test field strength
    100 A/m
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Voltage dips
    EN 61000-4-29
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Input, output (test level 1)
    100 kHz 1 MHz (Test Level 3 - symmetrical)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • ETIM 7.0
    EC002046
  • Protection class
    Special with SELV input and output
  • Depth
    125 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • EMC requirements, power plant
    IEC 61850-3
  • Low Voltage Directive
    Conformance with Low Voltage Directive 2014/35/EC
  • Additional text
    Test Level 2
  • Contact discharge
    8 kV (Test Level 4)
  • Electrostatic discharge
    EN 61000-4-2
  • Conducted interference
    EN 61000-4-6
  • Power frequency magnetic field
    EN 61000-4-8
  • Voltage dip
    0 %
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Alternating component of DC voltage
    EN 61000-4-17
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 10.0.1
    27210901
  • ETIM 6.0
    EC002046

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2910125

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo