Phoenix Contact 2906232 Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the
Phoenix Contact

Part#:2906232

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Set consisting of a 4-way signal conditioner with screw connection technology and a Rogowski coil 450 mm in length/140 mm in diameter for AC current measurement on busbars and power lines.The signal conditioner outputs 8 different standard signals on the

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2906232 Phoenix Contact price in the box on the right side or send a quick quote.

2906232 Product Details

  • Height
    110.5 mm
  • Measuring coil degree of protection
    IP67 (not assessed by UL)
  • Power consumption
    ≤ 1 W (at IOUT = 20 mA, 9.6 V DC, 600 Ω load)
  • Configurable/programmable
    Via DIP switches
  • Output voltage (sinusoidal, in no-load operation)
    100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))
  • Basic accuracy
    <± 0.2 %
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Torque
    0.5 Nm ... 0.6 Nm
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27210900
  • ETIM 6.0
    EC002048
  • ECLASS 7.0
    27210902
  • UNSPSC 18.0
    39121032
  • Ambient temperature (operation)
    -30 °C ... 80 °C (Measuring coil)
  • Nominal supply voltage
    24 V DC
  • Linearity error
    < 0.1 %
  • Input signal (at 50 Hz)
    100 mV (1000 A)
  • Current output signal
    0 mA ... 20 mA (via DIP switch)
  • Diameter of measuring coil
    8.3 mm ±0.2 mm
  • Standards/regulations
    IEC 61010-1
  • UL, USA/Canada
    UL 508 Listed
  • Screw thread
    M3
  • Electromagnetic compatibility
    Conformance with EMC Directive 2004/108/EC
  • Electrical isolation
    Reinforced insulation in accordance with IEC 61010-1
  • ECLASS 5.1
    27210900
  • ECLASS 5.0
    27210900
  • ECLASS 11.0
    27210902
  • UNSPSC 20.0
    39121032
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C (Measuring coil)
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Frequency measuring range
    40 Hz ... 20000 Hz
  • Output signal (at 50 Hz)
    100 mV (no load, at 1,000 A)
  • Output voltage (in no-load operation)
    VOUT = M * dI/dt
  • Conductor structure signal line
    2x 0.22 mm (Signal (tinned))
  • Test voltage
    3 kV (50 Hz, 1 min.)
  • Conductor cross section AWG
    26 ... 16
  • Noise emission
    EN 61000-6-4
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Designation
    CE
  • Depth
    120.5 mm
  • Measuring transducer degree of protection
    IP20
  • Position error
    <± 1 % (typical)
  • Measuring ranges (current)
    100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
  • Input impedance
    > 100 kΩ
  • Load/output load current output
    ≤ 600 Ω (20 mA)
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Overvoltage category
    II
  • Pollution degree
    2
  • Conformance
    CE-compliant
  • ECLASS 10.0.1
    27210902
  • ETIM 3.0
    EC002048
  • ETIM 4.0
    EC002048
  • Width
    6.2 mm
  • Maximum altitude
    > 4000 m
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Nominal supply voltage range
    9.6 V DC ... 30 V DC
  • Voltage output signal
    0 V ... 10 V (via DIP switch)
  • Coil material
    Elastollan
  • Identification
    CE-compliant
  • ECLASS 4.0
    27210900
  • ECLASS 9.0
    27210902
  • ETIM 7.0
    EC002048
  • UNSPSC 21.0
    39121032
  • ECLASS 6.0
    27210900
  • UNSPSC 19.0
    39121032
  • UNSPSC 13.2
    39121032
  • Length of measuring coil
    450 mm
  • Frequency range
    16 Hz ... 1000 Hz
  • Connection method
    Screw connection
  • Housing material
    PBT
  • Maximum transmission error
    ≤ 0.5 % (From the range end value)
  • Stripping length
    10 mm
  • Rated insulation voltage
    300 V
  • Typical measuring error
    < 1 %
  • Length of signal cable
    3000 mm
  • Connection name
    Measuring transducer side
  • Insulation
    double insulation

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2906232

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo