2903914 Phoenix Contact Electrical Safety Devices

Phoenix Contact 2903914 Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.
Phoenix Contact

Part#:2903914

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and push-in connection.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2903914 Phoenix Contact price in the box on the right side or send a quick quote.

2903914 Product Details

  • Width
    22.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 80 °C
  • Control supply voltage range
    19.2 V DC ... 30 V DC
  • Switching threshold
    9.6 V (“0” signal)
  • Rated operating current Ie
    0.6 A (AC-51)
  • Operating voltage range
    42 V AC ... 550 V AC
  • Depth
    114 mm
  • Rated control circuit supply voltage US
    24 V DC
  • Rated control supply current IS
    40 mA
  • Input name
    Control input
  • Switching level
    < 5 V DC (For EMERGENCY STOP)
  • Output name
    Acknowledge output
  • Load current range
    75 mA ... 600 mA (see to derating)
  • Motor starter type
    Direct starter
  • Assembly instructions
    alignable, for spacing see derating
  • Maximum power dissipation
    1.5 W
  • Stripping length
    10 mm
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Standards/regulations
    IEC 60947-1
  • FLA
    0.6 A (500 V AC)
  • ECLASS 4.1
    27021100
  • ECLASS 7.0
    27024002
  • ETIM 6.0
    EC001037
  • Type of note
    Notes on operation
  • Ambient temperature (operation)
    -25 °C ... 70 °C (observe derating)
  • Rated actuating voltage UC
    24 V DC
  • Rated actuating current IC
    5 mA (Input type 1)
  • Mains frequency
    50/60 Hz
  • Leakage current
    0 mA
  • Cooling time
    20 min. (for auto reset)
  • Operating voltage display
    Green LED
  • Connection method
    Push-in connection
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Overvoltage category
    III
  • Insulation
    Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
  • Category code
    NLDX
  • ECLASS 11.0
    27370905
  • ECLASS 9.0
    27370905
  • ETIM 3.0
    EC001037
  • UNSPSC 19.0
    25173902
  • Note
    Confirmation: floating change-over contact, signal contact
  • Maximum altitude
    ≤ 2000 m
  • Triggering voltage range
    19.2 V DC ... 30 V DC
  • Rated operating voltage Ue
    500 V AC
  • Switching capacity according to IEC 60947-5-1
    3 A (230 V, AC15)
  • Mounting type
    DIN rail mounting
  • Minimum power dissipation
    1.1 W
  • Status display
    Yellow LED
  • Rated insulation voltage
    500 V
  • Designation
    Category (ISO 13849)
  • Additional text
    Safe shutdown
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27024000
  • ETIM 2.0
    EC001037
  • ETIM 4.0
    EC001037
  • UNSPSC 7.0901
    39121514
  • UNSPSC 18.0
    25173902
  • Height
    107.5 mm
  • Degree of protection
    IP20
  • Type of protection
    Surge protection
  • Typical turn-off time
    < 30 ms
  • Trigger characteristic in acc. with IEC 60947-4-2
    Class 10A
  • Mounting position
    vertical (horizontal DIN rail, motor output below)
  • Operating mode
    100% operating factor
  • Connection name
    Load circuit
  • Conductor cross section AWG
    24 ... 14
  • Degree of pollution
    2
  • Certificate
    NLDX.E228652
  • Group installation
    20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27024000
  • UNSPSC 6.01
    30211915
  • UNSPSC 12.01
    39121514
  • UNSPSC 20.0
    25173902
  • Contact type
    1 changeover contact
  • Switching frequency
    ≤ 2 Hz (Load-dependent)
  • Indication
    Red LED
  • Rated surge voltage
    6 kV
  • Identification
    ≤ 3
  • SCCR
    100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
  • Horsepower ratings
    -
  • ECLASS 10.0.1
    27370905
  • ECLASS 4.0
    27021100
  • ECLASS 6.0
    27024000
  • ETIM 7.0
    EC001037
  • UNSPSC 11
    39121514
  • UNSPSC 13.2
    25173902
  • UNSPSC 21.0
    25173902

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2903914

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo