2903262 Phoenix Contact Electrical Safety Devices
Part#:2903262
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Multifunctional safety relay for emergency stop, safety doors, and light grid up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, pluggable Push-in terminal block (tool-free act
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903262 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- REACh SVHC Lead 7439-92-1
- Height 106.4 mm
- Max. permissible relative humidity (operation) 75 % (on average, 85% infrequently, non-condensing)
- Max. permissible humidity (storage/transport) 75 % (on average, 85% infrequently, non-condensing)
- Typ. starting time with Us 250 ms (when controlled via A1)
- Maximum switching frequency 0.5 Hz
- Limiting continuous current 6 A (N/O contact)
- Mechanical service life 10x 106 cycles
- Net weight 271.2 g
- Assembly instructions See derating curve
- Degree of protection IP20
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Category 4
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.1 27371900
- Depth 114.5 mm
- Input voltage range in reference to UN 0.85 ... 1.1
- Current consumption typ. 5 mA (Imax/Ix inputs)
- Status display 5x LED green
- Maximum switching voltage 250 V AC/DC
- Interrupting rating (ohmic load) max. 1500 VA (250 V AC, τ = 0 ms)
- Relay type Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
- Mounting type DIN rail mounting
- Min. degree of protection of inst. location IP54
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Designation Air clearances and creepage distances between the power circuits
- Safety Integrity Level Claim Limit (SIL CL) 3
- Rated insulation voltage 250 V AC
- ECLASS 5.0 27371900
- ETIM 6.0 EC001449
- UNSPSC 19.0 39122205
- Width 22.5 mm
- Maximum altitude ≤ 2000 m (Above sea level)
- Typical response time 175 ms (monitored/manual start)
- Typical release time 25 ms (when controlled via S11/S12 and S21/S22)
- Operating voltage display 1 x green LED
- Max. permissible overall conductor resistance 100 Ω
- Contact type 4 enabling current paths
- Maximum inrush current 6 A
- Switching capacity min. 0.1 W
- Output fuse 6 A gL/gG NEOZED (N/O contact)
- Nominal operating mode 100% operating factor
- Housing color yellow
- pluggable no
- Stop category 0
- Degree of pollution 2
- ECLASS 11.0 27371819
- ECLASS 6.0 27371800
- UNSPSC 20.0 39122205
- UNSPSC 18.0 39122205
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -25 °C ... 85 °C
- Nominal input voltage UN 24 V DC
- Concurrence ∞
- Protective circuit Surge protection Suppressor diode
- Filter time max. 1.5 ms (Test pulse duration; for all equivalent inputs)
- Inrush current, minimum 10 mA
- Switching capacity (360/h cycles) 5 A (0,1 Hz; DC13; 24 V)
- Mounting position vertical or horizontal
- Connection method Push-in connection
- Conductor cross-section AWG 24 ... 16
- Safety Integrity Level (SIL) 3
- Standards/regulations DIN EN 50178/VDE 0160
- Overvoltage category III
- ECLASS 4.0 40020600
- ECLASS 4.1 40020600
- ECLASS 9.0 27371819
- Ambient temperature (operation) -20 °C ... 45 °C (see derating curve)
- Typical input current at UN 125 mA (with actuated relays)
- Voltage at input/start and feedback circuit 24 V -15 %; +10 % (first channel: 24 V; second channel: 0 V)
- Recovery time 1 s (Availability time after activation of sensor circuit: 100ms)
- Contact material AgCuNi, +0.2 -0.4 µm Au
- Minimum switching voltage 10 V AC/DC
- Sq. Total current 72 A2 (TH2 = I12 + I22+ I32+ I42 (note derating))
- Maximum interrupting rating (inductive load) 48 W (24 V DC, τ = 40 ms)
- Stripping length 10 mm
- Performance level (PL) e (5 A DC13; 3 A AC15; 8760 cycles/year)
- Rated surge voltage/insulation 4 kV/basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).)
- ECLASS 10.0.1 27371819
- ECLASS 7.0 27371819
- ETIM 4.0 EC001449
- UNSPSC 21.0 39122205
- ETIM 7.0 EC001449
- UNSPSC 13.2 39121501
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨