Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865955 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Maximum altitude ≤ 2000 m
- Voltage drop < 3.5 V (in input isolating amplifier operation)
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Designation Safety Integrity Level (SIL, IEC 61508)
- Nominal supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Torque 0.5 Nm ... 0.6 Nm
- Width 12.5 mm
- Depth 114.5 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Signal input Passive current input
- Load/output load current output < 1000 Ω (20 mA)
- Degree of pollution 2
- Electromagnetic compatibility Conformance with EMC directive
- Protocols supported HART
- UL, USA/Canada UL 61010 Listed
- DNV GL-Vibration A
- Humidity B
- Vibration A
- ECLASS 10.0.1 27210120
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Current input signal 0 mA ... 20 mA
- Current output signal 0 mA ... 20 mA (active)
- Nominal supply voltage 24 V DC
- Degree of protection IP20 (not assessed by UL)
- Transmitter supply voltage > 21.5 V (20 mA)
- Transmission Behavior 1:1 to input signal
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Conductor cross section AWG 24 ... 14
- Transmission error, typical < 0.05 % (of final value)
- Status display Green LED (supply voltage)
- Height 112.5 mm
- Rated insulation voltage 300 Vrms
- Noise emission EN 61000-6-4
- ATEX II 3 G Ex nA II T4 Gc X
- Identification 2
- Certificate BVS PB 03/08-2
- EMC A
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
- Output behavior in the event of an error 0 mA (Cable break in the input)
- Power dissipation < 0.75 W (24 V DC / 20 mA / 1000 Ω)
- Max. current consumption < 44 mA (24 V DC / 20 mA / 1000 Ω)
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Connection name Test socket
- Step response (10-90%) < 200 µs (for jump 4 mA ... 20 mA, load 600 Ω)
- Housing material PA 6.6-FR
- HART function Yes
- DNV GL-Temperature B
- Additional text and EN 61326
- ECLASS 11.0 27210120
- Signal output Current output (active and passive)
- Output ripple < 20 mVrms
- Connection method Screw connection
- Stripping length 7 mm
- Maximum transmission error < 0.1 % (of final value)
- No. of channels 1
- Overvoltage category II
- Color gray
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Conformance CE-compliant, additionally EN 61326
- DNV GL-EMC A
- Temperature B
- China RoHS Environmentally Friendly Use Period = 50 years
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- ECLASS 4.1 27210100
- ECLASS 7.0 27210120
- UNSPSC 13.2 39121008
- UNSPSC 21.0 39121008
- Screw thread M3
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- DNV GL-Humidity B
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27210100
- ETIM 4.0 EC002653
- UNSPSC 6.01 30211506
- UNSPSC 12.01 39121008
- Power consumption < 1.8 W (20 mA / 1000 Ω)
- Max. diameter 2 mm
- ECLASS 6.0 27210100
- ETIM 6.0 EC002653
- UNSPSC 20.0 39121008
- UNSPSC 11 39121008
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- ECLASS 5.1 27210100
- UNSPSC 7.0901 39121008
- UNSPSC 19.0 39121008
- Maximum temperature coefficient < 0.01 %/K
- Interference emission EN 61000-6-4
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.0 27210100
- ECLASS 9.0 27210120
- ETIM 7.0 EC002653
- UNSPSC 18.0 39121008
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨