Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, screw connection,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2865722 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- DNV GL-Temperature B
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Temperature B
- China RoHS Environmentally Friendly Use Period = 50 years
- REACh SVHC Lead 7439-92-1
- Width 35 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing)
- Degree of protection IP20 (not assessed by UL)
- Current output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
- Behavior in the event of a sensor error according to NE 43 or freely configurable
- Maximum inrush current 2 A (250 V AC)
- Typical current consumption < 100 mA (24 V DC)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Step response (0–99%) typ. 1000 ms (With SIL)
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Color gray
- Max. output power Po 11 mW
- Additional text mixed circuit
- Noise emission EN 61000-6-4
- Contact type 3 changeover contacts
- Connection method Screw connection
- Torque 0.5 Nm ... 0.6 Nm
- Status display Green LED (supply voltage, PWR)
- Interference emission EN 61000-6-4
- Housing material PA 6.6-FR
- Depth 114.5 mm
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Input signal range -1000 mV ... 1000 mV
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Rated insulation voltage 300 Vrms
- Group IIC
- Typical deviation from the measuring range final value 2 %
- DNV GL-Humidity B
- Identification [Ex ia Ga] IIC
- Vibration A
- ECLASS 11.0 27210129
- ECLASS 5.1 27200206
- ETIM 3.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 19.0 41112105
- UNSPSC 21.0 41112105
- Max. output voltage Uo 6 V
- Standards/regulations EN 61000-4-6
- IECEx [Ex ia Ga] IIC
- Humidity B
- EMC A
- ECLASS 4.1 27210107
- ETIM 6.0 EC001596
- UNSPSC 6.01 30211506
- UNSPSC 13.2 39121008
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Load/output load voltage output ≥ 10 kΩ
- Mechanical service life 1x 105 cycles
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Maximum temperature coefficient 0.01 %/K
- Overvoltage category II
- Designation INMETRO
- Max. internal capacitance Ci 44 nF
- Power consumption < 2.4 W
- Screw thread M3
- Maximum transmission error 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Electromagnetic compatibility Conformance with EMC directive
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Maximum altitude ≤ 2000 m
- Shock 15g, according to IEC 60068-2-27
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Max. voltage output signal ± 11 V
- Voltage input signal -1 V ... 1 V
- Contact material AgSnO2, hard gold-plated
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Height 112.5 mm
- Ambient temperature (operation) -20 °C ... 65 °C
- Vibration (operation) 5g, accordance to IEC 60068-2-6
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
- Max. current output signal 22 mA
- Output name Relay output
- Maximum switching voltage 250 V AC (250 V DC)
- Stripping length 7 mm
- Conductor cross section AWG 24 ... 14
- Degree of pollution 2
- Electrical isolation 4-way, between input/output/power supply/switching output
- Max. internal inductance Li negligible
- ECLASS 9.0 27210129
- ETIM 7.0 EC001596
- UNSPSC 12.01 39121008
- Max. output current Io 7.4 mA
- Max. external capacitance Co 21 µF
- ECLASS 10.0.1 27210129
- ECLASS 7.0 27242601
- UNSPSC 20.0 41112105
- Max. external inductivity Lo 1 mH
- Safety-related maximum voltage Um 253 V AC/DC
- UL, USA/Canada UL 508 Listed
- Certificate DNV 18.0143 X
- UNSPSC 18.0 41112105
- ECLASS 4.0 27210107
- ECLASS 6.0 27242600
- ETIM 4.0 EC001596
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Vibration A
- ECLASS 5.0 27210107
- UNSPSC 11 39121008
- Conformance CE-compliant
- DNV GL-EMC A
- Enclosure Required protection according to the Rules shall be provided upon installation on board
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨