2838513 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2838513 LSA-PLUS plug (COMTRAB CTM) with protection for conductor pairs in floating signal circuits. Nominal voltage: 24 V DC
Phoenix Contact

Part#:2838513

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: LSA-PLUS plug (COMTRAB CTM) with protection for conductor pairs in floating signal circuits. Nominal voltage: 24 V DC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2838513 Phoenix Contact price in the box on the right side or send a quick quote.

2838513 Product Details

  • Depth
    53.5 mm
  • Housing material
    PA
  • Standards for cearances and creepage distances
    DIN VDE 0110-1
  • Number of positions
    2
  • Maximum continuous voltage UC
    ± 30 V DC
  • Residual current IPE
    ≤ 2 µA
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 70 V
  • Flammability rating according to UL 94
    V-0
  • Arrester can be tested with CHECKMASTER from software version:
    From SW rev. 1.10
  • Direction of action
    Line-Line & Line-Earth Ground
  • Nominal pulse current Ian (10/1000) µs (line-earth)
    100 A
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 70 V
  • Response time tA (line-line)
    ≤ 1 ns
  • Capacity (line-line)
    1.2 nF (f=1 MHz / VR= 0 V)
  • Surge protection fault message
    none
  • Ambient temperature (operation)
    -25 °C ... 75 °C
  • Overvoltage category
    II
  • Degree of pollution
    2
  • IEC test classification
    B2
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Residual voltage at In (line-line)
    ≤ 45 V
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 700 V
  • Response time tA (line-earth)
    ≤ 100 ns
  • Resistance per path
    3.3 Ω 10 %
  • Connection method OUT
    COMTRAB plug-in system
  • Width
    9.5 mm
  • Mounting type
    On CT-TERMIBLOCK and LSA-PLUS disconnect strip
  • Nominal voltage UN
    24 V DC
  • Rated current
    380 mA AC (25 °C)
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    1 kA
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    10 kA (in total)
  • Voltage protection level Up (line-earth)
    ≤ 700 V (C2 - 10 kV / 5 kA)
  • Voltage protection level Up static (line-earth)
    ≤ 60 V (C2 - 10 kV / 5 kA)
  • Height
    21 mm
  • Degree of protection
    IP20
  • Color
    black
  • Type
    LSA-PLUS module
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 700 V
  • Residual voltage with Ian (10/1000) µs (line-line)
    ≤ 25 V
  • Voltage protection level Up static (line-line)
    ≤ 45 V (C2 - 10 kV / 5 kA)
  • Voltage protection level Up (line-line)
    ≤ 70 V (C2 - 10 kV / 5 kA)
  • Impulse durability (line-earth)
    C2 - 4 kV / 2 kA
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • UNSPSC 13.2
    39121620
  • VDE requirement class
    B2
  • Total discharge current Itotal (10/350) µs
    2.5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Nominal pulse current Ian (10/1000) µs (line-line)
    100 A
  • Operating effective current IC at UC
    ≤ 5 µA
  • ETIM 3.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 20.0
    39121620
  • Residual voltage at In (line-earth)
    ≤ 60 V
  • Impulse durability (line-line)
    C2 - 4 kV / 2 kA
  • Connection method
    Spring contact
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27130807
  • ECLASS 5.1
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 7.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • Connection technology
    LSA-PLUS
  • ECLASS 10.0.1
    27130807
  • ECLASS 4.0
    27130800
  • ETIM 4.0
    EC000943
  • Residual voltage with Ian (10/1000) µs (line-earth)
    ≤ 12 V
  • Input attenuation aE, sym.
    0.3 dB (≤ 600 kHz)
  • Standards/regulations
    IEC 61643-21
  • ECLASS 4.1
    27130800
  • ECLASS 6.0
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 21.0
    39121620
  • Cut-off frequency fg (3 dB), sym. in 100 Ω system
    2.7 MHz
  • Alternating current carrying capacity (line-earth)
    5 A - 1 s
  • Connection method IN
    COMTRAB plug-in system
  • Standards/specifications
    IEC 61643-21 2000
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 2.0
    EC000943
  • UNSPSC 18.0
    39121620
  • UNSPSC 12.01
    39121610
  • UNSPSC 19.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2838513

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo