2832124 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2832124 Modular terminal block with three-stage surge protection for a floating Ex-i signal circuit, separate PE connection, nominal voltage: 24 V DC, for mounting on NS 35/7.5, terminal block width: 6.2 mm, terminal block height: 54.6 mm. HART-compatible
Phoenix Contact

Part#:2832124

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Modular terminal block with three-stage surge protection for a floating Ex-i signal circuit, separate PE connection, nominal voltage: 24 V DC, for mounting on NS 35/7.5, terminal block width: 6.2 mm, terminal block height: 54.6 mm. HART-compatible

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2832124 Phoenix Contact price in the box on the right side or send a quick quote.

2832124 Product Details

  • Depth
    54.6 mm
  • Degree of protection
    IP20 (with end cover)
  • Max. input current Ii
    250 mA (TA < 40 °C)
  • Rated current
    250 mA (40 °C)
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    500 A
  • Nominal pulse current Ian (10/1000) µs (line-line)
    100 A
  • Response time tA (line-line)
    ≤ 1 ns
  • ECLASS 4.1
    27130800
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Stripping length
    8 mm
  • IECEx
    Ex ia IIC T4...T6 Ga
  • Altitude
    ≤ 2000 m (amsl (above mean sea level))
  • Max. input voltage Ui
    30 V DC
  • Maximum continuous voltage UC
    30 V DC
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 2 MHz
  • Output voltage limitation at 1 kV/µs (line-line) spike
    ≤ 50 V
  • Voltage protection level Up (line-earth)
    ≤ 2.2 kV (C2 - 10 kV / 5 kA)
  • Response time tA (line-earth)
    ≤ 100 ns
  • Impulse durability (line-earth)
    C2 - 10 kV / 5 kA
  • Conductor cross section AWG
    24 ... 14
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • ECLASS 4.0
    27130800
  • ECLASS 7.0
    27130807
  • ETIM 3.0
    EC000943
  • UNSPSC 12.01
    39121610
  • UNSPSC 20.0
    39121620
  • ATEX
     II 1G Ex ia IIC T4...T6 Ga
  • Height
    79.6 mm
  • Maximum inner time factor (Ri/Li)
    0.1 µs
  • max. input power Pi
    0.75 W
  • Operating effective current IC at UC
    ≤ 5 µA
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 1.7 kV
  • Voltage protection level Up (line-line)
    ≤ 55 V (C1 - 1 kV/500 A)
  • Cut-off frequency fg (3 dB), sym. in 50 Ω system
    typ. 6 MHz
  • Surge protection fault message
    none
  • Screw thread
    M3
  • Connection method
    Screw terminal blocks
  • ECLASS 11.0
    27130807
  • ECLASS 5.0
    27130800
  • ETIM 4.0
    EC000943
  • ETIM 6.0
    EC000943
  • UNSPSC 11
    39121610
  • Ambient temperature (operation)
    -40 °C ... 40 °C (T6 / 85 °C)
  • Maximum inner capacitance Ci
    2 nF
  • IEC test classification
    C1
  • Residual current IPE
    ≤ 1 µA
  • Nominal pulse current Ian (10/1000) µs (line-earth)
    100 A
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 1.7 kV
  • Resistance per path
    4.7 Ω ±20 %
  • Alternating current carrying capacity (line-earth)
    0.5 A - 1 s
  • Standards/specifications
    EN 61643-21 2001 + A1:2009 + A2:2013
  • ECLASS 10.0.1
    27130807
  • ECLASS 6.0
    27130800
  • UNSPSC 6.01
    30212010
  • UNSPSC 19.0
    39121620
  • Width
    6.2 mm
  • Max. internal inductance Li
    1 µH
  • Nominal voltage UN
    24 V DC
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Output voltage limitation at 1 kV/µs (line-line) static
    ≤ 50 V
  • Input attenuation aE, sym.
    typ. 0.7 dB (≤ 400 kHz/50 Ω)
  • Max. required back-up fuse
    250 mA (T)
  • Tightening torque
    0.6 Nm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 2.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 18.0
    39121620
  • Capacity (line-line)
    ≤ 2 nF
  • UNSPSC 21.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2832124

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo