Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2811831 Phoenix Contact Electrical Measuring & Monitoring Instruments

Phoenix Contact 2811831 Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL
Phoenix Contact

Part#:2811831

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Freely programmable temperature transducer with analog output and 3 limit value relays, order configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2811831 Phoenix Contact price in the box on the right side or send a quick quote.

2811831 Product Details

  • Width
    35 mm
  • Output name
    Relay output
  • Humidity
    B
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.1
    27210121
  • ETIM 6.0
    EC002568
  • Maximum altitude
    ≤ 2000 m
  • Load/output load voltage output
    ≥ 10 kΩ
  • Contact material
    AgSnO2, hard gold-plated
  • Conductor cross section AWG
    24 ... 16
  • Electromagnetic compatibility
    Conformance with EMC directive
  • Electrical isolation
    4-way, between input/output/power supply/switching output
  • ATEX
     II 3 G Ex nA nC ic IIC T4 Gc X
  • Permissible humidity (operation)
    typ. 5 % ... 95 % (non-condensing)
  • DNV GL-Temperature
    B
  • DNV GL-EMC
    A
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Ambient temperature (operation)
    -20 °C ... 65 °C
  • Sensor types (RTD) that can be used
    Pt, Ni, Cu sensors: 2, 3, 4-wire
  • Current output signal
    4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
  • Maximum inrush current
    2 A (250 V AC)
  • Connection method
    Push-in connection
  • Degree of pollution
    2
  • Color
    gray
  • Noise emission
    EN 61000-6-4
  • DNV GL-Vibration
    A
  • Temperature
    B
  • Depth
    114.5 mm
  • Sensor types that can be used (TC)
    B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
  • Potentiometer resistance range
    0 Ω ... 50 kΩ
  • Max. current output signal
    22 mA
  • Behavior in the event of a sensor error
    according to NE 43 or freely configurable
  • Supply voltage range
    24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
  • Conductor cross section solid
    0.2 mm² ... 1.5 mm²
  • Interference emission
    EN 61000-6-4
  • Housing material
    PA 6.6-FR
  • Insulation
    Safe isolation in accordance with IEC/EN 61010-1
  • UL, USA/Canada
    UL 508 Listed
  • DNV GL-Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • Vibration
    A
  • ECLASS 10.0.1
    27210129
  • Conductor cross section flexible
    0.2 mm² ... 1.5 mm²
  • Overvoltage category
    II
  • Rated insulation voltage
    300 Vrms
  • Test voltage
    2.5 kV AC (50 Hz, 1 min.)
  • Conformance
    CE-compliant
  • Certificate
    DNV GL TAA000020C
  • Identification
    2
  • EMC
    A
  • Height
    116 mm
  • Noise immunity
    EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
  • Max. voltage output signal
    ± 11 V
  • Load/output load current output
    ≤ 600 Ω (at 20 mA)
  • Contact type
    3 changeover contacts
  • Power consumption
    < 2.4 W
  • Maximum switching voltage
    250 V AC (250 V DC)
  • Stripping length
    8 mm
  • Maximum transmission error
    0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
  • Maximum temperature coefficient
    0.01 %/K
  • Designation
    Safety Integrity Level (SIL, IEC 61508)
  • IECEx
    Ex nA nC ic IIC T4 Gc X
  • DNV GL-Humidity
    B
  • Enclosure
    Required protection according to the Rules shall be provided upon installation on board
  • ECLASS 11.0
    27210129
  • ECLASS 7.0
    27371503
  • ETIM 7.0
    EC002568
  • UNSPSC 12.01
    39121008
  • UNSPSC 19.0
    41112105
  • Input signal range
    -1000 mV ... 1000 mV
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Temperature measuring range
    -250 °C ... 2500 °C (Range depending on the sensor type)
  • ECLASS 4.1
    27210121
  • ECLASS 9.0
    27210129
  • UNSPSC 11
    39121008
  • UNSPSC 21.0
    41112105
  • ECLASS 4.0
    27210121
  • ECLASS 5.0
    27371500
  • ETIM 3.0
    EC001446
  • UNSPSC 13.2
    39121008
  • UNSPSC 20.0
    41112105
  • ETIM 4.0
    EC002653
  • UNSPSC 7.0901
    39121008
  • ECLASS 6.0
    27371500
  • UNSPSC 6.01
    30211506
  • UNSPSC 18.0
    41112105

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2811831

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo