2727378 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2727378 Inline power-level terminal blocks, electronic reversing load starter, up to 1.5 kW / 400 V AC
Phoenix Contact

Part#:2727378

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Inline power-level terminal blocks, electronic reversing load starter, up to 1.5 kW / 400 V AC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2727378 Phoenix Contact price in the box on the right side or send a quick quote.

2727378 Product Details

  • Depth
    109 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 3000 m above sea level)
  • Transmission speed
    500 kbps
  • Number of positions
    4
  • Output name
    Motor output
  • Nominal current range
    0.2 A ... 3.6 A
  • Supply voltage
    24 V DC (via voltage jumper)
  • Supply voltage range
    19.2 V DC ... 28.8 V DC (including all tolerances, including ripple)
  • Note on weight specifications
    without plug
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 6 kV contact discharge, criterion B, 8 kV air discharge, criterion B
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV
  • Protection class
    I (МЭК 61140, EN 61140, VDE 0140-1)
  • ECLASS 4.1
    27250300
  • Height
    224 mm
  • Degree of protection
    IP20
  • Number
    1
  • Permissible conductor cross section
    1 mm² ... 2.5 mm²
  • Frequency range
    50 Hz ... 60 Hz
  • Overspeed tripping
    ≥ 20 A (after 0.3 seconds)
  • Power consumption
    max. 1.2 W (entire device)
  • Width
    63 mm
  • Ambient temperature (operation)
    -25 °C ... 55 °C
  • Permissible humidity (storage/transport)
    10 % ... 85 % (non-condensing)
  • Note
    Notes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
  • Connection method
    COMBICON
  • Designation connection point
    Terminal strip X10
  • Parameterization range
    0.2 A ... 3.6 A (steps of 50/100/200 mA, via fieldbus)
  • Connection technology
    COMBICON
  • Net weight
    500 g
  • Ambient temperature (storage/transport)
    -25 °C ... 85 °C
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Designation
    Segment circuit supply (US)
  • Transmission physics
    Copper
  • Operating voltage
    200 V AC ... 440 V AC
  • Switching rate
    Max. 30 per minute (observe derating)
  • Type of contact
    Solid-state contact
  • Current consumption
    max. 50 mA
  • Mounting type
    DIN rail
  • Operating mode
    Process data mode with one byte
  • Mounting position
    Panel mounting on horizontal DIN rail
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, field strength: 3 V/m
  • ECLASS 10.0.1
    27242609
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    10 % ... 85 % (non-condensing)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27250300
  • ECLASS 6.0
    27242600
  • Interference emission
    Noise emission test as per EN 61000-6-4 Radio interference properties EN 55011 Class A
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 11.0
    27242609
  • ECLASS 5.1
    27242600
  • ETIM 2.0
    EC001433
  • ETIM 4.0
    EC001601
  • ETIM 6.0
    EC001605
  • UNSPSC 11
    43172015
  • UNSPSC 12.01
    43201404
  • Diagnostics messages
    Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
  • Max. current carrying capacity
    20 A
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 2g, evaluation criterion 1
  • ECLASS 9.0
    27242609
  • UNSPSC 6.01
    43172015
  • UNSPSC 21.0
    32151602
  • UNSPSC 13.2
    32151602
  • ECLASS 7.0
    27242609
  • ETIM 7.0
    EC001605
  • UNSPSC 19.0
    32151602
  • Assembly instructions
    To safeguard sufficient ventilation, ensure that there is an installation clearance of a minimum of 50 cm both above and below.
  • ETIM 3.0
    EC001601
  • UNSPSC 7.0901
    43201404
  • UNSPSC 20.0
    32151602
  • ECLASS 4.0
    27250300
  • UNSPSC 18.0
    32151602
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, supply lines DC: 0.5 kV/0.5 kV (symm./asymm.), criterion B, supply lines AC: 2 kV/4 kV (symm./asymm.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2727378

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo