About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2716703 Phoenix Contact price in the box on the right side or send a quick quote.
2716703 Product Details
- Number of levels 1
- Color gray
- Degree of pollution 3
- Overvoltage category III
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 2 kV
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of flexion and pull-out test Test passed
- UNSPSC 21.0 39121410
- ECLASS 7.0 27141106
- ETIM 3.0 EC001284
- UNSPSC 6.01 30211811
- UNSPSC 13.2 39121409
- Maximum load current 76 A (with 16 mm² conductor cross section)
- Nominal current IN 57 A
- Result of power-frequency withstand voltage test Test passed
- Potentials 2
- Insulating material group I
- Flammability rating according to UL 94 V2
- Bending test rotation speed 10 rpm
- Tensile test result Test passed
- Result of voltage-drop test Test passed
- Result of thermal test Test passed
- Width 29 mm
- Tightening torque max 1.8 Nm
- Conductor cross section solid max. 16 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.0 27141100
- ETIM 2.0 EC001284
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- UNSPSC 20.0 39121410
- Stripping length 12 mm
- Shock protection test specification IEC 60529:2001-02
- Bending test turns 135
- Result of temperature-rise test Test passed
- Bending test conductor cross section/weight 0.5 mm² / 0.3 kg
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Nominal cross section 10 mm²
- Number of connections 4
- Rated surge voltage 8 kV
- Nominal voltage UN 800 V
- Length 33 mm
- Screw thread M4
- Conductor cross section AWG max. 6
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section flexible max. 10 mm²
- Internal cylindrical gage A3
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 10.0.1 27141120
- ECLASS 5.0 27141100
- ETIM 6.0 EC001284
- UNSPSC 11 39121410
- UNSPSC 12.01 39121410
- Result of surge voltage test Test passed
- Open side panel No
- Finger protection guaranteed
- Height 31 mm
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 6 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27141100
- ECLASS 9.0 27141120
- ECLASS 6.0 27141100
- ETIM 7.0 EC001284
- Number of positions 2
- Insulating material PA
- Maximum power dissipation for nominal condition 1.82 W
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 5.1 27141100
- ETIM 4.0 EC001284
- UNSPSC 19.0 39121410
- Short-time current 1.92 kA
- Short circuit stability result Test passed
- Static insulating material application in cold -40 °C
- Connection method Screw connection
- Tightening torque, min 1.5 Nm
- Conductor cross section flexible min. 0.5 mm²
- Max. AWG conductor cross section, flexible 8
- 2 conductors with same cross section, solid min. 0.5 mm²
- 2 conductors with same cross section, stranded max. 6 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 125°C)
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Connection in acc. with standard CSA
- Conductor cross section flexible, with ferrule with plastic sleeve max. 16 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Conductor cross section AWG min. 20
- Conductor cross section flexible, with ferrule without plastic sleeve max. 16 mm²
- 2 conductors with same cross section, solid max. 6 mm²
- Min. AWG conductor cross section, flexible 20
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.5 mm²
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Relative insulation material temperature index (Elec., UL 746 B) 125 °C
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.5 mm²
- Conductor cross section short circuit testing 16 mm²
- 2 conductors with same cross section, stranded min. 0.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 6 mm²
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
2716703
Select Qty:
Average response time: 11 minutes
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Relevant products
Do you have questions?
We’re here for you ✨