Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

2316390 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 2316390 Axioline P bus coupler for PROFINET. Connects to PROFIBUS PA power supplies and Axioline P I/O modules along the AXIOLINE P local bus. (includes power supply connector and bus base module)
Phoenix Contact

Part#:2316390

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

About the product: Axioline P bus coupler for PROFINET. Connects to PROFIBUS PA power supplies and Axioline P I/O modules along the AXIOLINE P local bus. (includes power supply connector and bus base module)

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2316390 Phoenix Contact price in the box on the right side or send a quick quote.

2316390 Product Details

  • Width
    45 mm
  • Conductor cross section solid max.
    1.5 mm²
  • Depth
    75 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Designation
    Supply of the Axioline P local bus UBus
  • Conductor cross section flexible min.
    0.2 mm²
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Conductor cross section solid min.
    0.2 mm²
  • Stripping length
    8 mm
  • Conductor cross section AWG max.
    16
  • Height
    126.93 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Utilization restriction
    Use in potentially explosive areas is not permitted in China.
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Mounting type
    DIN rail mounting
  • Mounting position
    any
  • Protective circuit
    Surge protection of the supply voltage electronic
  • Current consumption
    3 A (via bus base module)
  • Interference emission
    Noise emission test as per EN 61000-6-4 Radio interference properties according to EN 55011/EN 55032 Class A
  • ECLASS 11.0
    27242608
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Conductor cross section AWG min.
    24
  • Note on weight specifications
    with bus base module
  • Number
    2
  • Supply voltage
    5 V DC (via bus base module)
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Net weight
    321.5 g
  • Transmission physics
    Ethernet in RJ45 twisted pair
  • Number of supported devices
    max. 8 (per redundant PROFIBUS PA segments)
  • Power supply unit
    2 A
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV
  • ATEX
     II 3 G Ex ec IIC T4 Gc IBExU 18ATEXB018X
  • Ambient temperature (operation)
    -40 °C ... 70 °C (Mounting position: wall mounting on horizontal DIN rail)
  • Degree of protection
    IP20
  • Conductor cross section flexible max.
    1.5 mm²
  • Color
    gray
  • Degree of pollution
    2
  • Amount of process data
    max.
  • Supply voltage range
    19.2 V DC ... 30 V DC
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • IECEx
    Ex ec IIC T4 Gc IECEx IBE 18.0023X
  • Overvoltage category
    II
  • ETIM 7.0
    EC001604
  • Connection method
    RJ45 socket, auto negotiation and auto crossing
  • Transmission speed
    100 Mbps (Full duplex)
  • Maximum altitude
    2000 m
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 2g
  • China RoHS
    Environmentally Friendly Use Period = 25;
  • ECLASS 10.0.1
    27242608
  • REACh SVHC
    Lead 7439-92-1
  • UL, USA/Canada
    Class I, Div. 2, Groups A, B, C, D T4Class I, Zone 2, IIC T4
  • ECLASS 9.0
    27242608
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ETIM 6.0
    EC001604
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

2316390

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo