Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1166809 Phoenix Contact Terminal Blocks

Phoenix Contact 1166809 Test disconnect terminal block, connection method: Push-in connection, cross section: 0.5 mm² - 6 mm² , AWG: 20 - 10, width: 8.2 mm, color: gray
Phoenix Contact

Part#:1166809

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 48

Nov 24, 2024

Test disconnect terminal block, connection method: Push-in connection, cross section: 0.5 mm² - 6 mm² , AWG: 20 - 10, width: 8.2 mm, color: gray

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1166809 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Tractive force setpoint
    80 N
  • Nominal cross section
    6 mm²
  • Insulating material group
    I
  • Nominal current IN
    30 A (with 6 mm² conductor cross section)
  • Result of surge voltage test
    Test passed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Potentials
    1
  • Degree of pollution
    3
  • Nominal voltage UN
    1000 V
  • UNSPSC 6.01
    30211811
  • UNSPSC 12.01
    39121410
  • End cover width
    2.2 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Connection cross sections directly pluggable
    0.75 mm² 6 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 3.0
    EC000902
  • UNSPSC 7.0901
    39121410
  • UNSPSC 19.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    57.1 mm
  • Conductor cross section solid min.
    0.75 mm²
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section AWG min.
    20
  • Max. AWG conductor cross section, flexible
    10
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141126
  • ECLASS 7.0
    27141126
  • ECLASS 5.0
    27141100
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Width
    8.2 mm
  • Height NS 35/7,5
    49.6 mm
  • Connection
    1 level
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Internal cylindrical gage
    A4
  • Operating temperature
    -60 °C ... 85 °C
  • ECLASS 4.0
    27141100
  • ECLASS 4.1
    27141100
  • ETIM 2.0
    EC000902
  • ECLASS 9.0
    27141126
  • UNSPSC 13.2
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Length
    100.8 mm
  • Conductor cross section solid max.
    6 mm²
  • Min. AWG conductor cross section, flexible
    20
  • Conductor cross section AWG max.
    10
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 55 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 10.0.1
    27141126
  • ETIM 4.0
    EC000902
  • UNSPSC 11
    39121410
  • ETIM 7.0
    EC000902
  • UNSPSC 21.0
    39121410
  • Finger protection
    guaranteed
  • Back of the hand protection
    guaranteed
  • Shock test result
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Number of connections
    2
  • Overvoltage category
    III
  • Maximum load current
    30 A (with 6 mm² conductor cross section)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Color
    gray
  • Rated surge voltage
    8 kV
  • Bending test turns
    135
  • Conductor cross section tensile test
    6 mm²
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of aging test
    Test passed
  • Test duration per axis
    5 h
  • Number of shocks per direction
    3
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    1.31 W
  • Open side panel
    Yes
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Bending test rotation speed
    10 rpm
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Requirements, voltage drop
    U1 ≤ 3.2 mV; U2 ≤ 1.5 x U1
  • Short-time current
    1.25 kA
  • Insulating material
    PA
  • Surge voltage test setpoint
    9.8 kV
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Oscillation, broadband noise test result
    Test passed
  • Acceleration
    30g
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock form
    Half-sine
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Result of flexion and pull-out test
    Test passed
  • Result of voltage-drop test
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock duration
    18 ms
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • UNSPSC 20.0
    39121410
  • ASD level
    6.12 (m/s2)2/Hz
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • UNSPSC 18.0
    39121410
  • Conductor cross section short circuit testing
    4 mm²
  • Result of thermal test
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Tensile test result
    Test passed
  • ETIM 6.0
    EC000902

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$11.96

Stock:

48

Select Qty:

$11.96

$11.96 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo