Safe extension module with 8 safe inputs and 2 safe outputs, 2 reset inputs, 2 signal outputs, 4 clock outputs, TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, pluggable Push-in terminal block, TBUS connector included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1105523 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth 113.6 mm
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Current consumption typ. 10 mA (typically with US)
- Inrush current max. 750 mA (Δt 1 s)
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Description of the input IEC 61131-2 type 3
- Output name O1A, O1B, O2A, O2B
- Nominal output voltage 24 V DC (Supply via A1)
- Leakage current max. 100 µA
- Switching frequency max. 1/4 x tCycle [Hz]
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Restart time min. 5 s (Boot time)
- Height 107.74 mm
- Designation Air clearances and creepage distances between the power circuits
- Protective circuit Serial protection against polarity reversal
- Number of inputs 2
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Protective circuit/component Suppressor diode
- Nominal output voltage range 18 V DC ... 27.6 V DC (US - 1.2 V)
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Discharging circuit Yes, internal
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Nominal voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Mounting type DIN rail mounting
- Min. degree of protection of inst. location IP54
- Housing color yellow
- Stripping length 10 mm
- Safety Integrity Level (SIL) 2
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Standards/regulations EN 50178
- ECLASS 11.0 27371819
- ECLASS 9.0 27371819
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Rated control supply current IS typ. 40 mA (Outputs inactive)
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (provide external protection, typically 8 A)
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Input voltage range "1" signal 11 V DC ... 28.8 V DC
- Input current range "0" signal < 1 mA
- Limiting continuous current 100 mA (per channel)
- Output voltage when switched off max. 0.1 V
- Max. inductive load max. 2.4 mH
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Response time see user manual
- Nominal operating mode 100% operating factor
- Mounting position vertical or horizontal
- Housing material Polyamide PA non-reinforced
- Connection method Push-in connection
- Conductor cross-section AWG 24 ... 16
- Performance level (PL) e (2-channel wiring)
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 10.0.1 27371819
- Width 22.61 mm
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Maximum altitude ≤ 2000 m (Above sea level)
- Power consumption at US typ. 0.96 W (Outputs inactive)
- Input name Reset inputs
- Cable length max. 100 m (per output)
- Output description PNP, IEC 61131-2 type 0.5
- Number of outputs 4
- Max. capacitive load max. 470 nF
- Test pulses ≤ 220 µs (Test pulse duration)
- Voltage 24 V DC (via A1)
- Cycle time see user manual
- Net weight 141 g
- Degree of protection IP20
- Protection class III (EN 50178)
- Status display 1 x LED (green), 2 x LED (orange)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Rated surge voltage/insulation Basic insulation 4 kV between 24 V power supply and I/Os to the housing
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- Conformance CE-compliant
- Assembly instructions Observe derating
- Operating voltage display 1 x green LED
- Indication 2 x LED (red)
- pluggable Yes
- Stop category 0
- Rated insulation voltage 250 V AC
- Degree of pollution 2
- Overvoltage category II
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨