1105522 Phoenix Contact Electrical Safety Devices
Part#:1105522
Manufacturer:Phoenix Contact
Product Lifecycle:Active
In-stock parts: 38
Nov 23, 2024
Safe extension module with 8 safe inputs and 2 safe outputs, 2 reset inputs, 2 signal outputs, 4 clock outputs, TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, pluggable screw terminal block, TBUS connector included
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1105522 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Screw thread M3
- Depth 113.6 mm
- Designation Air clearances and creepage distances between the power circuits
- Rated control circuit supply voltage US 24 V DC -20 % / +20 % (provide external protection, typically 8 A)
- Height 112.58 mm
- Ambient temperature (storage/transport) -20 °C ... 85 °C
- Current consumption typ. 10 mA (typically with US)
- Protective circuit Serial protection against polarity reversal
- Max. permissible overall conductor resistance 1.2 kΩ (Input and reset circuit at US)
- Cable length max. 100 m (per output)
- Limiting continuous current 100 mA (per channel)
- Switching frequency max. 1/4 x tCycle [Hz]
- Voltage 24 V DC (via A1)
- Nominal voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Assembly instructions Observe derating
- Housing color yellow
- pluggable Yes
- Width 22.61 mm
- Max. permissible humidity (storage/transport) 95 % (non-condensing)
- Description of the input IEC 61131-2 type 3
- Input voltage range "0" signal 0 V DC ... 5 V DC
- Output name O1A, O1B, O2A, O2B
- Nominal output voltage range 18 V DC ... 27.6 V DC (US - 1.2 V)
- Leakage current max. 100 µA
- Short-circuit protection Yes (self-limitation at 1.1 A)
- Discharging circuit Yes, internal
- Restart time min. 5 s (Boot time)
- Net weight 159 g
- Protection class III (EN 50178)
- Housing material Polyamide PA non-reinforced
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Safety Integrity Level Claim Limit (SIL CL) 3 (2-channel wiring)
- Rated surge voltage/insulation Basic insulation 4 kV between 24 V power supply and I/Os to the housing
- Conformance CE-compliant
- ECLASS 9.0 27371819
- Max. permissible relative humidity (operation) 95 % (non-condensing)
- Rated control supply current IS typ. 40 mA (Outputs inactive)
- Power consumption at US typ. 0.96 W (Outputs inactive)
- Input name Reset inputs
- Protective circuit/component Suppressor diode
- Number of outputs 4
- Nominal output voltage 24 V DC (Supply via A1)
- Max. inductive load max. 2.4 mH
- Test pulses ≤ 220 µs (Test pulse duration)
- Response time see user manual
- Mounting position vertical or horizontal
- Mounting type DIN rail mounting
- Indication 2 x LED (red)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Stop category 0
- Rated insulation voltage 250 V AC
- Shock 10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
- ECLASS 10.0.1 27371819
- Ambient temperature (operation) -10 °C ... 55 °C (observe derating)
- Maximum altitude ≤ 2000 m (Above sea level)
- Filter time 250 ms ±2 ms (Test pulse rate > 500 ms)
- Number of inputs 2
- Input current range "0" signal < 1 mA
- Output voltage when switched off max. 0.1 V
- Ohmic load min. 50 Ω (Observe limiting continuous current)
- Maximum inrush current 1.1 A (Δt = 3 s at Us)
- Nominal operating mode 100% operating factor
- Degree of protection IP20
- Status display 1 x LED (green), 2 x LED (orange)
- Connection method Screw connection
- Torque 0.5 Nm ... 0.6 Nm
- Performance level (PL) e (2-channel wiring)
- Overvoltage category II
- ECLASS 11.0 27371819
- Inrush current max. 750 mA (Δt 1 s)
- Input voltage range "1" signal 11 V DC ... 28.8 V DC
- Output description PNP, IEC 61131-2 type 0.5
- Max. capacitive load max. 470 nF
- Error detection time at 1-channel structure < 3.5 s (OFF state)
- Output voltage range 18.2 V DC ... 27.8 V DC (US - 1 V)
- Cycle time see user manual
- Min. degree of protection of inst. location IP54
- Operating voltage display 1 x green LED
- Stripping length 7 mm
- Conductor cross-section AWG 24 ... 12
- Standards/regulations EN 50178
- Vibration (operation) 10 Hz ... 150 Hz, 2g
- Safety Integrity Level (SIL) 2
- Degree of pollution 2
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$500.83
Stock:
38
Select Qty:
$500.83
$500.83 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨