Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1104985 Phoenix Contact Electrical Safety Devices

Phoenix Contact 1104985 Safe extension module with 4 safe analog inputs, 0 V ... 10 V; 0 mA or 4 mA ... 20 mA; TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in screw terminal block, TBUS connector included
Phoenix Contact

Part#:1104985

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 45

Apr 24, 2024

About the product: Safe extension module with 4 safe analog inputs, 0 V ... 10 V; 0 mA or 4 mA ... 20 mA; TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in screw terminal block, TBUS connector included

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1104985 Phoenix Contact price in the box on the right side or send a quick quote.

1104985 Product Details

  • Depth
    113.6 mm
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Power consumption at US
    typ. 1.96 W (without sensor supply)
  • Number of inputs
    4
  • Scanning rate
    2.5/5/10/16.6/20/50/60/100/200/400/800/1000/2000/4000 Hz
  • Precision
    typ. ± 2 % (as current input, relative to the measuring range final value)
  • Frequency
    20 Hz (max. recommended sensor signal frequency, as current input)
  • Description
    Sensor supply voltage per analog input
  • Cycle time
    see user manual
  • Mounting type
    DIN rail mounting
  • Operating voltage display
    1 x green LED
  • Conductor cross-section AWG
    24 ... 12
  • Torque
    0.5 Nm ... 0.6 Nm
  • Standards/regulations
    EN 50178
  • Degree of pollution
    2
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Height
    112.58 mm
  • Max. permissible relative humidity (operation)
    95 % (non-condensing)
  • Rated control circuit supply voltage US
    24 V DC -20 % / +20 % (external fuse, typically 6 A)
  • Description of the input
    Safety-oriented analog inputs, configurable as current or voltage inputs, galvanically isolated
  • Input name
    IN S1, IN S2, IN S3, IN S4
  • Permissible voltage
    max. 24 V (as current input)
  • Max. permissible current
    max. 35 mA (as current input)
  • Permissible cable length
    max. 100 m (per input)
  • Response time
    see user manual
  • Net weight
    160 g
  • Assembly instructions
    Observe derating
  • Protection class
    III (EN 50178)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Screw thread
    M3
  • Overvoltage category
    II
  • Conformance
    CE-compliant
  • ECLASS 10.0.1
    27371819
  • Ambient temperature (operation)
    -10 °C ... 55 °C (observe derating)
  • Rated control supply current IS
    typ. 82 mA (without sensor supply)
  • Protective circuit
    Overload protection Overload detection at  38 mA
  • Current input signal
    0 mA ... 25 mA (Measuring range)
  • Input resistance of voltage input
    185 kΩ 25 %
  • Resolution (current)
    381 nA
  • Supply voltage
    24 V DC ±3 %
  • Short-circuit-proof
    yes
  • Nominal operating mode
    100% operating factor
  • Housing material
    Polyamide PA non-reinforced
  • pluggable
    Yes
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Stop category
    0
  • Width
    22.61 mm
  • Max. permissible humidity (storage/transport)
    95 % (non-condensing)
  • Inrush current
    max. 14 A (Δt = 1 ms at Us)
  • Filter time
    typ. 5 ms (in the event of voltage dips at Us)
  • Note regarding the connection technology
    shielded
  • Input resistance current input
    290 Ω 25 %
  • A/D converter resolution
    16 bit
  • Limit frequency (3 dB)
    160 Hz (RC low pass, 1st order, as current input)
  • Current
    max. 30 mA (Sensor current recording per channel)
  • Degree of protection
    IP20
  • Housing color
    yellow
  • Connection method
    Screw connection
  • Safety Integrity Level (SIL)
    2
  • Rated insulation voltage
    250 V AC
  • Shock
    10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
  • ECLASS 9.0
    27371819
  • Ambient temperature (storage/transport)
    -20 °C ... 85 °C
  • Designation
    Air clearances and creepage distances between the power circuits
  • Connection technology
    2-conductor, 3-conductor or 4-conductor (2-conductor sensor signal + 2-conductor sensor supply)
  • Voltage input signal
    0 V ... 12 V (Measuring range)
  • Resolution (voltage)
    152 µV
  • Temperature coefficients
    typ. ± 0.07 %/K
  • Restart time
    min. 5 s (Boot time)
  • Mounting position
    vertical or horizontal
  • Min. degree of protection of inst. location
    IP54
  • Status display
    4x LED (yellow, red)
  • Stripping length
    7 mm
  • Performance level (PL)
    e (2-channel wiring)
  • Safety Integrity Level Claim Limit (SIL CL)
    3 (2-channel wiring)
  • Rated surge voltage/insulation
    Basic insulation 4 kV between all current paths and housing
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 11.0
    27371819

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$1,084.04

1104985

Stock:

45

Select Qty:

$1,084.04

$1,084.04 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo