Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

1104887 Phoenix Contact Electrical Safety Devices

Phoenix Contact 1104887 Safe extension module with 16 safe inputs; TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in Push-in terminal block, TBUS connector included
Phoenix Contact

Part#:1104887

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 50

Apr 25, 2024

About the product: Safe extension module with 16 safe inputs; TBUS interface, up to SILCL 3, Cat. 4/PL e, SIL 3, plug-in Push-in terminal block, TBUS connector included

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1104887 Phoenix Contact price in the box on the right side or send a quick quote.

1104887 Product Details

  • Ambient temperature (operation)
    -10 °C ... 55 °C (observe derating)
  • Depth
    113.6 mm
  • Designation
    Air clearances and creepage distances between the power circuits
  • Inrush current
    < 2.3 A (Δt = 1 ms at Us)
  • Input voltage range "1" signal
    11 V DC ... 28.8 V DC
  • Cable length
    max. 100 m (per output)
  • Maximum inrush current
    1.1 A (Δt = 3 s  at Us)
  • Max. capacitive load
    max. 470 nF
  • Cycle time
    see user manual
  • Mounting position
    vertical or horizontal
  • Protection class
    III (EN 50178)
  • pluggable
    Yes
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Performance level (PL)
    e (2-channel wiring)
  • Rated surge voltage/insulation
    Basic insulation 4 kV between 24 V power supply and I/Os to the housing
  • Rated insulation voltage
    250 V AC
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Height
    107.74 mm
  • Max. permissible humidity (storage/transport)
    95 % (non-condensing)
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Filter time
    min. 3 ms ±2 ms (adjustable)
  • Input name
    IN1 ... IN16
  • Protective circuit/component
    Suppressor diode
  • Nominal voltage range
    18.2 V DC ... 27.8 V DC (US - 1 V)
  • Output voltage when switched off
    max. 0.1 V
  • Nominal operating mode
    100% operating factor
  • Mounting type
    DIN rail mounting
  • Indication
    2 x LED (red)
  • Conductor cross-section AWG
    24 ... 16
  • Stop category
    0
  • Safety Integrity Level Claim Limit (SIL CL)
    3 (2-channel wiring)
  • Overvoltage category
    II
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ECLASS 10.0.1
    27371819
  • Max. permissible relative humidity (operation)
    95 % (non-condensing)
  • Rated control supply current IS
    typ. 40 mA
  • Number of inputs
    16
  • Input current range "0" signal
    < 1 mA
  • Output description
    PNP, IEC 61131-2 Typ 0,1
  • Leakage current
    max. 100 µA
  • Short-circuit protection
    Yes (self-limitation at 1.1 A)
  • Restart time
    min. 5 s (Boot time)
  • Net weight
    141 g
  • Housing material
    Polyamide PA non-reinforced
  • Status display
    1 x LED (green), 2 x LED (orange)
  • Width
    22.61 mm
  • Ambient temperature (storage/transport)
    -20 °C ... 85 °C
  • Power consumption at US
    typ. 0.96 W
  • Protective circuit
    Serial protection against polarity reversal
  • Input voltage range "0" signal
    0 V DC ... 5 V DC
  • Voltage
    24 V DC (via A1)
  • Number of outputs
    4
  • Test pulses
    ≤ 200 µs (Test pulse duration)
  • Discharging circuit
    Yes, internal
  • Min. degree of protection of inst. location
    IP54
  • Degree of protection
    IP20
  • Connection method
    Push-in connection
  • Operating voltage display
    1 x green LED
  • Stripping length
    10 mm
  • Standards/regulations
    EN 50178
  • ECLASS 11.0
    27371819
  • ECLASS 9.0
    27371819
  • Rated control circuit supply voltage US
    24 V DC -20 % / +20 % (external fuse, typically 4 A)
  • Description of the input
    Safety-related digital inputs
  • Current consumption
    typ. 7.5 mA (typically with US)
  • Max. permissible overall conductor resistance
    max. 1.2 kΩ (Input and reset circuit at US)
  • Limiting continuous current
    100 mA (per channel)
  • Max. inductive load
    max. 2.4 mH
  • Response time
    see user manual
  • Assembly instructions
    Observe derating
  • Housing color
    yellow
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Safety Integrity Level (SIL)
    2
  • Degree of pollution
    2
  • Shock
    10g for Δt = 16 ms (continuous shock, 1000 shocks in each space direction)
  • Conformance
    CE-compliant

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 5 days!

1-year warranty

$379.31

1104887

Stock:

50

Select Qty:

$379.31

$379.31 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo