1087079 Phoenix Contact Programmable Logic Controllers

Phoenix Contact 1087079 Axioline P, Analog output module, Analog outputs: 4 (HART), 0 mA ... 20 mA, 4 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, degree of protection: IP20, including bus base module and connec
Phoenix Contact

Part#:1087079

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 73

Apr 26, 2024

About the product: Axioline P, Analog output module, Analog outputs: 4 (HART), 0 mA ... 20 mA, 4 mA ... 20 mA, connection method: 2-conductor, transmission speed in the local bus: 100 Mbps, HART functionality, degree of protection: IP20, including bus base module and connec

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1087079 Phoenix Contact price in the box on the right side or send a quick quote.

1087079 Product Details

  • Height
    126.1 mm
  • Air pressure (storage/transport)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Note on the connection method
    Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
  • Conductor cross section solid min.
    0.2 mm²
  • Note on weight specifications
    with connectors and bus base module
  • Supply voltage
    5 V DC (via bus base module)
  • Transmission speed
    100 Mbps
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion A, supply lines DC: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), ±1 kV to shielded I/O cables
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • Overvoltage category
    II
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Conductor cross section AWG min.
    24
  • Color
    traffic grey A RAL 7042
  • Maximum altitude
    2000 m
  • Current consumption
    max. 135 mA
  • UL, USA/Canada
    Class I, Div. 2, Groups A, B, C, D T4
  • ECLASS 9.0
    27242601
  • Width
    53.6 mm
  • Ambient temperature (operation)
    -40 °C ... 70 °C (Standard)
  • Designation
    Supply of the Axioline P local bus UBus
  • Conductor cross section solid max.
    1.5 mm²
  • Mounting type
    DIN rail
  • Degree of pollution
    2
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV
  • IECEx
    IECEx UL 20.0002XEx ec IIC T4 Gc
  • ECLASS 10.0.1
    27242601
  • ECLASS 11.0
    27242601
  • Stripping length
    8 mm
  • Note on dimensions
    The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Air pressure (operation)
    70 kPa ... 106 kPa (up to 2000 m above sea level)
  • Connection method
    Bus base module
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Supply voltage range
    19.2 V DC ... 30 V DC (via bus base module (UL) at AXL P BK...)
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • ATEX
    DEMKO 20 ATEX 2334XII 3G Ex ec IIC T4 Gc
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A
  • Utilization restriction
    Use in potentially explosive areas is not permitted in China.
  • Depth
    77.14 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Conductor cross section flexible max.
    1.5 mm²
  • Net weight
    0 g
  • Test section
    5 V supply of the local bus (UBus) / functional ground 500 V AC 62 Hz 1 min.
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • China RoHS
    Environmentally Friendly Use Period = 25;

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$605.10

1087079

Stock:

73

Select Qty:

$605.10

$605.10 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo