Feed-through terminal block, nom. voltage: 800 V, nominal current: 24 A, connection method: Push-in connection, number of connections: 2, number of positions: 1, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, width: 5.2 mm, height: 35.3 mm, color: gray, m
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1078960 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of connections 2
- Area of application Railway industry
- Nominal cross section 2.5 mm²
- Insulating material PA
- Rated surge voltage 8 kV
- Finger protection guaranteed
- Surge voltage test setpoint 9.8 kV
- Bending test turns 135
- Result of voltage-drop test Test passed
- Short circuit stability result Test passed
- Ageing test for screwless modular terminal block temperature cycles 192
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- Shock duration 18 ms
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Height NS 35/7,5 36.8 mm
- Stripping length 8 mm ... 10 mm
- Conductor cross section AWG max. 12
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.0 27141121
- ECLASS 7.0 27141120
- UNSPSC 7.0901 39121410
- UNSPSC 18.0 39121410
- Potentials 1
- Maximum load current 28 A (with 4 mm² conductor cross section, rigid)
- Result of surge voltage test Test passed
- Result of flexion and pull-out test Test passed
- Conductor cross section tensile test 4 mm²
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Short-time current 0.3 kA
- Result of aging test Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Acceleration 30g
- Shock test result Test passed
- Number of shocks per direction 3
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Height 35.3 mm
- Height NS 35/15 44.3 mm
- Conductor cross section AWG min. 26
- Min. AWG conductor cross section, flexible 26
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 10.0.1 27141120
- ECLASS 4.1 27141121
- ECLASS 9.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 19.0 39121410
- ETIM 7.0 EC000897
- Number of positions 1
- Color gray
- Degree of pollution 3
- Open side panel Yes
- Nominal voltage UN 800 V
- Result of power-frequency withstand voltage test Test passed
- Bending test rotation speed 10 rpm
- Result of tight fit on support Test passed
- Result of temperature-rise test Test passed
- Result of thermal test Test passed
- ASD level 6.12 (m/s2)2/Hz
- Test duration per axis 5 h
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 5.2 mm
- Connection 1 level
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section flexible max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1 mm²
- Connection cross sections directly pluggable 0.5 mm² 4 mm² 20 12
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 5.1 27141100
- ETIM 3.0 EC000897
- ETIM 2.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 13.2 39121410
- Number of levels 1
- Flammability rating according to UL 94 V0
- Overvoltage category III
- Nominal current IN 24 A (at 2.5 mm²)
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 2 kV
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Tight fit on carrier NS 35
- Conductor cross section short circuit testing 2.5 mm²
- Oscillation, broadband noise test result Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 50.8 mm
- Connection method Push-in connection
- Conductor cross section solid min. 0.5 mm²
- Conductor cross section flexible min. 0.14 mm²
- Internal cylindrical gage A3
- ECLASS 11.0 27141120
- ECLASS 6.0 27141100
- UNSPSC 20.0 39121410
- UNSPSC 21.0 39121410
- Insulating material group I
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Tensile test result Test passed
- Tractive force setpoint 60 N
- Requirements, voltage drop U1 ≤ 3.2 mV; U2 ≤ 1.5 x U1
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test spectrum Service life test category 2, bogie-mounted
- Shock form Half-sine
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- End cover width 2.2 mm
- Conductor cross section solid max. 4 mm²
- Max. AWG conductor cross section, flexible 12
- Conductor cross section flexible, with ferrule without plastic sleeve min. 1.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 5.0 27141120
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
This item can ship within 24h!
1-year warranty
$2.05
Stock:
31,523
Select Qty:
$2.05
$2.05 each
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨