Phoenix Contact 1066718 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, Screw connection, input: 12 V DC - 24 V DC, output: 24 V DC / 2.5 A
Phoenix Contact

Part#:1066718

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Checking verified in-stock parts...

About the product: Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, Screw connection, input: 12 V DC - 24 V DC, output: 24 V DC / 2.5 A

About the category: DC-DC Converters convert a direct current voltage input into a different direct current voltage output

About the manufacturer: Phoenix Contact develops and manufactures industrial electrical and electronic technology products that power, protect, connect and automate systems and equipment.

Check out the 1066718 Phoenix Contact price in the box on the right side or send a quick quote.

1066718 Product Details

  • Height
    99 mm
  • Power dissipation SLEEP MODE
    < 1 W
  • Power loss nominal load max.
    < 8 W
  • Degree of pollution
    2
  • EMC requirements for noise emission
    EN 61000-6-3
  • Identification
    DNV GL
  • Electromagnetic HF field
    EN 61000-4-3
  • Comments
    Criterion A
  • Input voltage range
    9 V DC ... 24 V DC -25 % (SELV)
  • Switch-on time
    < 1 s
  • Inrush current integral (I2t)
    typ. 0.1 A2s
  • Type test (IEC/EN 60950-1) B
    4 kV DC
  • Type test (IEC/EN 60950-1) D
    0.5 kV DC
  • Stripping length
    8 mm
  • Conductor cross section AWG
    26 ... 14
  • Nominal output current (IN)
    2.5 A
  • System deviation, static
    < 1 % (change in load, static 10 % ... 90 %)
  • Residual ripple
    < 20 mVPP
  • Feedback voltage resistance
    ≤ 35 V DC
  • UOut
    > 0.9 x USet (LED lights up green)
  • Time
    320000 h
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Width
    32 mm
  • Efficiency
    typ. 92.1 % (24 V DC)
  • Ambient temperature (start-up type tested)
    -40 °C
  • Overvoltage category EN 61010-1
    II (≤ 5000 m)
  • Standards/regulations
    EN 61000-4-29
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Noise emission
    EN 55016
  • Contact discharge
    8 kV (Test Level 4)
  • Electric strength, max.
    35 V DC (60 s)
  • Type test (IEC/EN 60950-1) A
    2.6 kV DC
  • Input fuse
    15 A (fast blow, internal)
  • Production test B
    2 kV DC
  • Conductor cross section solid
    0.14 mm² ... 2.5 mm²
  • Flexible conductor cross section flexible (ferrule, w/o plastic sleeve)
    0.2 mm² ... 2.5 mm²
  • Nominal output voltage (UN)
    24 V DC
  • System deviation, dynamic
    < 2 % (Dynamic load change 10 % ... 90 %, 10 Hz)
  • Short-circuit-proof
    yes
  • Protection against overvoltage at the output (OVP)
    ≤ 32 V DC
  • MTBF (IEC 61709, SN 29500)
    > 1347000 h (25 °C)
  • Output current
    5 A
  • Protection class
    II
  • Width with alternative assembly
    90 mm
  • Mains buffering
    typ. 16 ms (24 V DC)
  • Typical current consumption
    typ. 7.2 A (12 V DC)
  • Type test (IEC/EN 60950-1) C
    0.5 kV DC
  • Connection method
    Screw connection
  • Production test D
    0.5 kV DC
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity)
  • Static Boost (IStat.Boost)
    3.125 A (≤ 40 °C)
  • Dynamic Boost (IDyn.Boost)
    5 A (≤ 60 °C (4,9 s))
  • Connection in parallel
    Yes, for redundancy and increased capacity
  • Rise time
    < 1 s (UOUT (10 % ... 90 %))
  • Temperature
    30 °C
  • Main converter stage
    70 kHz ... 150 kHz (Main converter stage)
  • Degree of protection
    IP20
  • Depth with alternative assembly
    32 mm
  • Maximum power dissipation in no-load condition
    < 1.3 W
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Designation
    Shipbuilding
  • DNV GL conducted interference
    Class B
  • Electrostatic discharge
    EN 61000-4-2
  • Input
    2 kV (symmetrical)
  • Output
    1 kV (Test Level 3 - symmetrical)
  • I/O/S
    asymmetrical
  • Test level 1
    15 Hz 150 Hz (Test Level 3)
  • Input, output (test level 2)
    1 kHz (Test Level 2 - asymmetrical)
  • Criterion A
    Normal operating behavior within the specified limits.
  • Inrush current limitation typical
    8.6 A
  • Insulation voltage input/output
    2.6 kV DC (type test)
  • Production test A
    1.2 kV DC
  • Production test C
    0.5 kV DC
  • Flexible conductor cross section (ferrule with plastic sleeve)
    0.25 mm² ... 2.5 mm²
  • Conductor cross section flexible
    0.14 mm² ... 2.5 mm²
  • Magnetic circuit breaker tripping
    A1 ... A4 / B2 / C1 ... C2 / Z1 ... Z4
  • System deviation, input voltage change
    < 0.1 % (change in input voltage ±10 %)
  • No-load proof
    yes
  • Connection in series
    yes
  • POut
    > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting)
  • Voltage
    1 kV
  • Auxiliary converter stage
    4 kHz ... 70 kHz (Auxiliary converter stage)
  • Depth
    90 mm
  • Height with alternative assembly
    99 mm
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • EMC requirements, power plant
    IEC 61850-3
  • DNV GL noise radiation
    Class B
  • Frequency range
    50 Hz ... 60 Hz
  • Test field strength
    1000 A/m
  • Signal
    2 kV (Test Level 4 - symmetrical)
  • Voltage dip
    0 %
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Test level 6
    0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
  • Signals (test level 1)
    1 kHz (Test Level 2 - symmetrical)
  • Weight
    0.246 kg
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Vibration (operation)
    < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
  • Standard designation
    Mains variation/undervoltage
  • Conducted noise emission
    EN 55016
  • Additional text
    Test Level 2
  • Fast transients (burst)
    EN 61000-4-4
  • Conducted interference
    EN 61000-4-6
  • Voltage dips
    EN 61000-4-11
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Test level 5
    16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
  • Attenuated oscillating wave
    EN 61000-4-18
  • Signals (test level 2)
    1 kHz (Test Level 2 - asymmetrical)
  • Discharge in air
    8 kV (Test Level 3)
  • Surge voltage load (surge)
    EN 61000-4-5
  • Frequency
    60 Hz
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 4
    15 kHz 150 kHz (Test Level 3)
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Power frequency magnetic field
    EN 61000-4-8
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Test level 2
    150 Hz 1.5 kHz (Test Level 3)
  • Test level 3
    1.5 kHz 15 kHz (Test Level 3)
  • Input, output (test level 1)
    1 kHz (Test Level 2 - symmetrical)
  • ECLASS 9.0
    27210901

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

Shipping and Delivery Worldwide

calculate cost and time at Checkout


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo