1066703 Phoenix Contact AC/DC Power Supplies
Part#:1066703
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Primary-switched power supply unit, QUINT POWER, Screw connection, input: 12 V DC - 24 V DC, output: 24 V DC / 1.3 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1066703 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight0.171 kg
- Mains buffering typ. 2 ms (12 V DC)
- Inrush current limitation typical typ. 1.6 A
- Production test A 3 kV AC
- Nominal output current (IN) 1.3 A
- Protection against overvoltage at the output (OVP) < 32 V DC
- Temperature 25 °C
- Height 99 mm
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
- Conducted noise emission EN 55016
- Electromagnetic HF field EN 61000-4-3
- Signal 2 kV (Test Level 4 - symmetrical)
- Number of periods 0.5 / 1 / 5 / 50 periods
- Test level 2 16.67 Hz 50 Hz 60 Hz (Test Level 4)
- Noise emission EN 55016
- Input voltage range 12 V DC ... 24 V DC -25 % ... +33 % (SELV)
- Switch-on time < 1 s
- Insulation voltage input/output 2.6 kV DC (type test)
- Stripping length 10 mm
- Setting range of the output voltage (USet) 24 V DC ... 28 V DC (> 24 V DC, constant capacity)
- Dynamic Boost (IDyn.Boost) 2.6 A (≤ 60 °C (4,9 s))
- Feedback voltage resistance ≤ 35 V DC
- Output current 2.5 A
- Protection class II
- Efficiency typ. 90.4 % (12 V DC)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electric strength, max. 35 V DC (60 s)
- Inrush current integral (I2t) typ. 0.1 A2s
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Static Boost (IStat.Boost) 1.625 A (≤ 40 °C)
- Voltage 300 V (1 s)
- Main converter stage 70 kHz ... 150 kHz (Main converter stage)
- Depth 90 mm
- Ambient temperature (start-up type tested) -40 °C
- Degree of pollution 2
- Standard designation Limitation of harmonic line currents
- Electrostatic discharge EN 61000-4-2
- Comments Criterion B
- Frequency 60 Hz
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- Type test (IEC/EN 60950-1) A 4 kV AC
- Connection method Push-in connection
- Nominal output voltage (UN) 24 V DC
- Time 432000 h
- Degree of protection IP20
- Width 22.5 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Overvoltage category EN 61010-1 II (≤ 5000 m)
- Identification CB scheme (IEC 61010-1, IEC 61010-2-201)
- Standards/regulations EN 61000-3-2
- Contact discharge 8 kV (Test Level 4)
- Frequency range 50 Hz ... 60 Hz
- Input 2 kV (symmetrical)
- Voltage dip 0 %
- Voltage dips EN 61000-4-11
- Test level 1 16.67 Hz 50 Hz 60 Hz (Test Level 3)
- ECLASS 9.0 27210901
- Typical current consumption typ. 3.75 A (12 V DC)
- Typical response time 700 ms (from SLEEP MODE)
- Input fuse 15 A (fast blow, internal)
- Conductor cross section AWG 24 ... 14
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- MTBF (IEC 61709, SN 29500) > 1347000 h (25 °C)
- Auxiliary converter stage 4 kHz ... 70 kHz (Auxiliary converter stage)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Vibration (operation) < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
- EMC requirements for noise immunity EN 61000-6-1
- Designation SIQ
- Discharge in air 8 kV (Test Level 3)
- Test field strength 1000 A/m
- Surge voltage load (surge) EN 61000-4-5
- Power frequency magnetic field EN 61000-4-8
- Additional text Test Level 2
- Criterion A Normal operating behavior within the specified limits.
- Attenuated oscillating wave EN 61000-4-18
- Fast transients (burst) EN 61000-4-4
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- I/O/S asymmetrical
- Pulse-shape magnetic field EN 61000-4-9
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨