Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1066714 Phoenix Contact AC/DC Power Supplies

Phoenix Contact 1066714 Primary-switched power supply unit, QUINT POWER, Push-in connection, input: 12 V DC - 24 V DC, output: 24 V DC / 2.5 A
Phoenix Contact

Part#:1066714

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Primary-switched power supply unit, QUINT POWER, Push-in connection, input: 12 V DC - 24 V DC, output: 24 V DC / 2.5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1066714 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Weight0.246 kg
  • Typical current consumption
    typ. 7.2 A (12 V DC)
  • Inrush current integral (I2t)
    < 0.1 A2s
  • Insulation voltage input/output
    1.5 kV DC (type test)
  • Connection method
    Push-in connection
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Noise emission
    EN 55016
  • Discharge in air
    8 kV (Test Level 3)
  • Electromagnetic HF field
    EN 61000-4-3
  • Comments
    Criterion B
  • Surge voltage load (surge)
    EN 61000-4-5
  • I/O/S
    asymmetrical
  • Frequency
    60 Hz
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Attenuated oscillating wave
    EN 61000-4-18
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.
  • Mains buffering
    typ. 14 ms (12 V DC)
  • Type test (IEC/EN 60950-1) A
    4 kV AC
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Conductor cross section AWG
    24 ... 14
  • Nominal output voltage (UN)
    24 V DC
  • Static Boost (IStat.Boost)
    3.125 A (≤ 40 °C)
  • Input voltage range
    12 V DC ... 24 V DC -25 % ... +33 % ()
  • Inrush current limitation typical
    8.6 A
  • Input fuse
    15 A (fast blow, internal)
  • Production test A
    3 kV AC
  • Stripping length
    10 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Setting range of the output voltage (USet)
    24 V DC ... 28 V DC (> 24 V DC, constant capacity)
  • Nominal output current (IN)
    2.5 A
  • Feedback voltage resistance
    ≤ 35 V DC
  • MTBF (IEC 61709, SN 29500)
    > 1347000 h (25 °C)
  • Temperature
    25 °C
  • Voltage
    300 V (1 s)
  • Main converter stage
    70 kHz ... 150 kHz (Main converter stage)
  • Protection class
    II
  • Width
    32 mm
  • Depth
    90 mm
  • Efficiency
    typ. 89.5 % (12 V DC)
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • Vibration (operation)
    < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
  • Climatic class
    3K3 (in acc. with EN 60721)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - Safe isolation
    IEC 61558-2-16
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Contact discharge
    8 kV (Test Level 4)
  • Frequency range
    50 Hz ... 60 Hz
  • Input
    2 kV (symmetrical)
  • Signal
    2 kV (Test Level 4 - symmetrical)
  • Power frequency magnetic field
    EN 61000-4-8
  • Additional text
    Test Level 2
  • Voltage dips
    EN 61000-4-11
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Dynamic Boost (IDyn.Boost)
    5 A (≤ 60 °C (4,9 s))
  • Protection against overvoltage at the output (OVP)
    < 32 V DC
  • Output current
    2.5 A
  • Time
    432000 h
  • Auxiliary converter stage
    4 kHz ... 70 kHz (Auxiliary converter stage)
  • Degree of protection
    IP20
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Height
    106 mm
  • Ambient temperature (start-up type tested)
    -40 °C
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Degree of pollution
    2
  • Overvoltage category EN 61010-1
    II (≤ 5000 m)
  • Standard - Safety of transformers
    EN 61558-2-16
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Conducted noise emission
    EN 55016
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    1000 A/m
  • Fast transients (burst)
    EN 61000-4-4
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Voltage dip
    0 %
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • Criterion A
    Normal operating behavior within the specified limits.
  • ECLASS 9.0
    27210901

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo