Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

1066704 Phoenix Contact DC/DC Converters

Phoenix Contact 1066704 Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, Push-in connection, input: 12 V DC - 24 V DC, output: 12 V DC / 2.5 A
Phoenix Contact

Part#:1066704

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1

Nov 19, 2024

Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, Push-in connection, input: 12 V DC - 24 V DC, output: 12 V DC / 2.5 A

About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1066704 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Weight0.173 kg
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 14
  • Setting range of the output voltage (USet)
    5 V DC ... 15 V DC (> 12 V DC, constant capacity)
  • Output current
    2.5 A
  • Inflammability class in acc. with UL 94 (housing / terminal blocks)
    V0
  • Depth
    90 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of pollution
    2
  • Standard - Safe isolation
    IEC 61558-2-16
  • Input voltage range
    12 V DC ... 24 V DC -25 % ... +33 % (SELV)
  • Inrush current limitation typical
    1.5 A (after 1 ms)
  • Production test A
    3 kV AC
  • Static Boost (IStat.Boost)
    3.125 A (≤ 40 °C)
  • MTBF (IEC 61709, SN 29500)
    > 1347000 h (25 °C)
  • Voltage
    300 V (1 s)
  • Main converter stage
    70 kHz ... 150 kHz (Main converter stage)
  • Height
    106 mm
  • Ambient temperature (operation)
    -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
  • Maximum altitude
    ≤ 5000 m (> 2000 m, observe derating)
  • Shock
    18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Overvoltage category EN 61010-1
    II (≤ 5000 m)
  • Standard – Safety extra-low voltage
    IEC 61010-1 (SELV)
  • Electrostatic discharge
    EN 61000-4-2
  • Test field strength
    1000 A/m
  • Fast transients (burst)
    EN 61000-4-4
  • I/O/S
    asymmetrical
  • Additional text
    Test Level 2
  • Asymmetrical conducted disturbance variables
    EN 61000-4-16
  • Attenuated oscillating wave
    EN 61000-4-18
  • ECLASS 9.0
    27210901
  • Mains buffering
    typ. 3 ms (12 V DC)
  • Insulation voltage input/output
    2.6 kV DC (type test)
  • Stripping length
    10 mm
  • Nominal output voltage (UN)
    12 V DC
  • Feedback voltage resistance
    ≤ 25 V DC
  • Auxiliary converter stage
    4 kHz ... 70 kHz (Auxiliary converter stage)
  • Width
    22.5 mm
  • Climatic class
    3K3 (in acc. with EN 60721)
  • Typical current consumption
    typ. 3.55 A (12 V DC)
  • Input fuse
    15 A (fast blow, internal)
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Dynamic Boost (IDyn.Boost)
    5 A (≤ 60 °C (4,9 s))
  • Temperature
    25 °C
  • Degree of protection
    IP20
  • Hood version
    Polycarbonate
  • Max. permissible relative humidity (operation)
    ≤ 95 % (at 25 °C, non-condensing)
  • EMC requirements for noise immunity
    EN 61000-6-1
  • Standard - Electrical safety
    IEC 61010-2-201 (SELV)
  • Standard - safety for equipment for measurement, control, and laboratory use
    IEC 61010-1
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Noise emission
    EN 55016
  • Discharge in air
    8 kV (Test Level 3)
  • Frequency range
    50 Hz ... 60 Hz
  • Surge voltage load (surge)
    EN 61000-4-5
  • Frequency
    60 Hz
  • Voltage dip
    0 %
  • Pulse-shape magnetic field
    EN 61000-4-9
  • Criterion A
    Normal operating behavior within the specified limits.
  • Criterion C
    Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
  • Inrush current integral (I2t)
    typ. 0.05 A2s
  • Type test (IEC/EN 60950-1) A
    4 kV AC
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Nominal output current (IN)
    2.5 A
  • Protection against overvoltage at the output (OVP)
    ≤ 18 V DC
  • Time
    432000 h
  • Protection class
    II
  • Efficiency
    typ. 91.1 % (12 V DC)
  • Ambient temperature (start-up type tested)
    -40 °C
  • Vibration (operation)
    < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6)
  • Standard - Safety of transformers
    EN 61558-2-16
  • Standard – Limitation of mains harmonic currents
    EN 61000-3-2
  • Contact discharge
    8 kV (Test Level 4)
  • Comments
    Criterion B
  • Output
    1 kV (Test Level 3 - symmetrical)
  • Signal
    2 kV (Test Level 4 - symmetrical)
  • Voltage dips
    EN 61000-4-11
  • Test level 1
    16.67 Hz 50 Hz 60 Hz (Test Level 3)
  • Test level 2
    16.67 Hz 50 Hz 60 Hz (Test Level 4)
  • Conducted noise emission
    EN 55016
  • Electromagnetic HF field
    EN 61000-4-3
  • Input
    2 kV (symmetrical)
  • Conducted interference
    EN 61000-4-6
  • Power frequency magnetic field
    EN 61000-4-8
  • Number of periods
    0.5 / 1 / 5 / 50 periods
  • Attenuated sinusoidal oscillations (ring wave)
    EN 61000-4-12
  • Criterion B
    Temporary impairment to operational behavior that is corrected by the device itself.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 24h!

1-year warranty

$142.99

Stock:

1

Select Qty:

$142.99

$142.99 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo