Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1046951 Phoenix Contact Terminal Blocks

Phoenix Contact 1046951 Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 500 V, nominal current: 17.5 A, connection method: Push-in connection, number of
Phoenix Contact

Part#:1046951

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 13

May 1, 2024

About the product: Distribution block, bridged internally, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 500 V, nominal current: 17.5 A, connection method: Push-in connection, number of

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1046951 Phoenix Contact price in the box on the right side or send a quick quote.

1046951 Product Details

  • Number of connections
    18
  • Insulating material
    PA
  • Maximum load current
    22 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Short-time current
    0.3 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2018-05
  • Acceleration
    30g
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Number of shocks per direction
    3
  • Shock duration
    18 ms
  • Length
    58.1 mm
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section AWG max.
    14
  • Nominal cross section
    1.5 mm²
  • Overvoltage category
    III
  • Maximum total current
    26 A
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of surge voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Setpoint
    1 N
  • Short circuit stability result
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Flammability rating according to UL 94
    V0
  • Potentials
    1
  • Maximum power dissipation for nominal condition
    0.56 W
  • Nominal current IN
    17.5 A
  • Back of the hand protection
    guaranteed
  • Bending test turns
    135
  • Result of voltage-drop test
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Result of aging test
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    21.6 mm
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section flexible min.
    0.14 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • UNSPSC 12.01
    39121410
  • UNSPSC 19.0
    39121410
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • UNSPSC 21.0
    39121410
  • UNSPSC 13.2
    39121410
  • UNSPSC 18.0
    39121410
  • UNSPSC 20.0
    39121410
  • Rated surge voltage
    6 kV
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock test result
    Test passed
  • Note
    Notes on operation The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of thermal test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test duration per axis
    0.0013888888889 h
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2018-05
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height NS 15
    26.4 mm
  • Max. AWG conductor cross section, flexible
    14
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Internal cylindrical gage
    A1 / B1
  • ECLASS 11.0
    27141120
  • ECLASS 5.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 6.01
    30211811
  • Tight fit on carrier
    NS 35/NS 15
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection method
    Push-in connection
  • Min. AWG conductor cross section, flexible
    20
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm² 26 14
  • ECLASS 4.1
    27141120
  • ETIM 2.0
    EC000897
  • UNSPSC 11
    39121410
  • Number of levels
    1
  • Insulating material group
    I
  • Nominal voltage UN
    500 V
  • Finger protection
    guaranteed
  • Result of tight fit on support
    Test passed
  • Result of temperature-rise test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Static insulating material application in cold
    -60 °C
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section AWG min.
    26
  • ECLASS 4.0
    27141120
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141120
  • ETIM 4.0
    EC000897
  • Color
    red
  • Degree of pollution
    3
  • Open side panel
    No
  • Conductor cross section short circuit testing
    2.5 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 7.0
    27141120
  • UNSPSC 7.0901
    39121410
  • Height NS 35/7,5
    28.4 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.1
    27141120
  • ETIM 3.0
    EC000897
  • ETIM 7.0
    EC000897

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$7.88

1046951

Stock:

13

Select Qty:

$7.88

$7.88 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo