Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1030131 Phoenix Contact Terminal Blocks

Phoenix Contact 1030131 Installation terminal block, Push-in connection, cross section: 0.5 mm² - 25 mm², AWG: 20 - 4, width: 12.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15
Phoenix Contact

Part#:1030131

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Installation terminal block, Push-in connection, cross section: 0.5 mm² - 25 mm², AWG: 20 - 4, width: 12.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1030131 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Color
    blue
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Potentials
    1
  • Overvoltage category
    III
  • Nominal voltage UN
    1000 V
  • Finger protection
    guaranteed
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Setpoint
    5 N
  • Short-time current
    3 kA
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Acceleration
    30g
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Length
    81.9 mm
  • Height NS 35/15
    56 mm
  • Number of connections
    1
  • Insulating material
    PA
  • Nominal current IN
    70 A (for 16 mm² conductor cross section)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Result of voltage-drop test
    Test passed
  • Result of thermal test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock test result
    Test passed
  • Shock duration
    18 ms
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height
    46.8 mm
  • Conductor cross section solid min.
    2.5 mm²
  • Conductor cross section flexible max.
    16 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    2.5 mm²
  • Connection cross sections directly pluggable
    2.5 mm² 25 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 4.0
    27141100
  • ECLASS 7.0
    27141125
  • UNSPSC 6.01
    30211811
  • UNSPSC 7.0901
    39121410
  • UNSPSC 18.0
    39121410
  • Nominal cross section
    16 mm²
  • Rated surge voltage
    6 kV
  • Maximum load current
    76 A
  • Back of the hand protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test turns
    135
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Test duration per axis
    5 h
  • Number of shocks per direction
    3
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    48.5 mm
  • Conductor cross section solid max.
    25 mm²
  • Conductor cross section AWG max.
    4
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    2.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    4 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141125
  • ETIM 3.0
    EC001329
  • UNSPSC 13.2
    39121410
  • Number of levels
    1
  • Degree of pollution
    3
  • Maximum power dissipation for nominal condition
    2.43 W
  • Open side panel
    No
  • Result of flexion and pull-out test
    Test passed
  • Tight fit on carrier
    NS 35
  • Conductor cross section short circuit testing
    25 mm²
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Width
    12.2 mm
  • Connection
    1 level
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    16 mm²
  • Internal cylindrical gage
    A7
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141100
  • ETIM 6.0
    EC001329
  • UNSPSC 19.0
    39121410
  • Result of surge voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of temperature-rise test
    Test passed
  • Result of aging test
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Stripping length
    18 mm ... 20 mm
  • Conductor cross section AWG min.
    20
  • Max. AWG conductor cross section, flexible
    4
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    16 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 4.1
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 21.0
    39121410
  • Connection method
    Push-in connection
  • Min. AWG conductor cross section, flexible
    24
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141125
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141125
  • ETIM 7.0
    EC001329
  • UNSPSC 12.01
    39121410
  • UNSPSC 20.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo