Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1020177 Phoenix Contact Terminal Blocks

Phoenix Contact 1020177 Knife disconnect terminal block, nom. voltage: 500 V, nominal current: 20 A, connection method: Push-in connection, cross section: 0.5 mm² - 10 mm², AWG: 20 - 8, length: 74.1 mm, width: 8.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15, NS 32
Phoenix Contact

Part#:1020177

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Knife disconnect terminal block, nom. voltage: 500 V, nominal current: 20 A, connection method: Push-in connection, cross section: 0.5 mm² - 10 mm², AWG: 20 - 8, length: 74.1 mm, width: 8.2 mm, color: gray, mounting: NS 35/7,5, NS 35/15, NS 32

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1020177 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Color
    gray
  • Degree of pollution
    3
  • Nominal voltage UN
    500 V
  • Back of the hand protection
    guaranteed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of tight fit on support
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Short circuit stability result
    Test passed
  • Number of connections
    2
  • Flammability rating according to UL 94
    V0
  • Overvoltage category
    III
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Result of flexion and pull-out test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of voltage-drop test
    Test passed
  • Setpoint
    5 N
  • Potentials
    1
  • Rated surge voltage
    6 kV
  • Maximum load current
    20 A
  • Result of surge voltage test
    Test passed
  • Finger protection
    guaranteed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Result of temperature-rise test
    Test passed
  • Nominal cross section
    6 mm²
  • Insulating material group
    I
  • Open side panel
    No
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test turns
    135
  • Tight fit on carrier
    NS 32/NS 35
  • Acceleration
    5g
  • Number of levels
    1
  • Insulating material
    PA
  • Maximum power dissipation for nominal condition
    1.31 W
  • Nominal current IN
    20 A
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Result of thermal test
    Test passed
  • Result of aging test
    Test passed
  • ASD level
    0.964 (m/s2)2/Hz
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test duration per axis
    5 h
  • Number of shocks per direction
    3
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Length
    74.1 mm
  • Connection
    1 level
  • Conductor cross section AWG min.
    20
  • Conductor cross section AWG max.
    8
  • UNSPSC 19.0
    39121410
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Shock form
    Half-sine
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    8.2 mm
  • Connection method
    Push-in connection
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • ECLASS 4.0
    27141121
  • ETIM 2.0
    EC000897
  • UNSPSC 11
    39121410
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Shock duration
    30 ms
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Conductor cross section solid min.
    1 mm²
  • Min. AWG conductor cross section, flexible
    20
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • ECLASS 11.0
    27141126
  • ECLASS 5.0
    27141100
  • ECLASS 5.1
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410
  • Oscillation, broadband noise test result
    Test passed
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Height
    43.8 mm
  • Height NS 35/15
    51.2 mm
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible min.
    0.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Internal cylindrical gage
    A5
  • ECLASS 4.1
    27141121
  • ETIM 3.0
    EC000897
  • ETIM 4.0
    EC000902
  • UNSPSC 21.0
    39121410
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock test result
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    43.7 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Max. AWG conductor cross section, flexible
    10
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm² When using TWIN ferrules, we recommend a minimum ferrule length of 13 mm.
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141126
  • ETIM 7.0
    EC000902
  • UNSPSC 13.2
    39121410
  • UNSPSC 20.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1 mm²
  • Connection cross sections directly pluggable
    1 mm² 10 mm²
  • ECLASS 10.0.1
    27141126
  • ECLASS 7.0
    27141126
  • ETIM 6.0
    EC000902
  • UNSPSC 6.01
    30211811
  • UNSPSC 18.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo