Nikki Gonzales
Nick Goetz
Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

1009832 Phoenix Contact Electrical Safety Devices

Phoenix Contact 1009832 Safety relay for emergency stop, safety doors and light grids up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, TBUS interface, US = 24 V DC, pluggable push-in terminal
Phoenix Contact

Part#:1009832

Manufacturer:Phoenix Contact

Product Lifecycle:Active

In-stock parts: 1

04/19/2024

About the product: Safety relay for emergency stop, safety doors and light grids up to SILCL 3, Cat. 4, PL e, 1- or 2-channel operation, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, TBUS interface, US = 24 V DC, pluggable push-in terminal

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Safety Devices that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1009832 Phoenix Contact price in the box on the right side or send a quick quote.

1009832 Product Details

  • Height
    117.5 mm
  • Rated control supply current IS
    typ. 75 mA
  • Description of the input
    non-safety-related
  • Number of inputs
    4
  • Concurrence
  • Limiting continuous current
    6 A
  • Switching frequency
    max. 0.5 Hz
  • Rated insulation voltage
    250 V
  • Overvoltage category
    III
  • ECLASS 9.0
    27371819
  • Ambient temperature (operation)
    -20 °C ... 55 °C (observe derating)
  • Designation
    Air clearances and creepage distances between the power circuits
  • Inrush current
    min. 10 mA
  • Input name
    Start circuit
  • Max. permissible overall conductor resistance
    50 Ω
  • Switching voltage
    min. 10 V AC/DC
  • Output fuse
    10 A gL/gG
  • Voltage
    approx. 23.9 V DC (Us - 0.1 V)
  • Typical response time at US
    200 ms (automatic start)
  • Conformance
    CE-compliant
  • Width
    22.5 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Max. permissible humidity (storage/transport)
    75 % (on average, 85% infrequently, non-condensing)
  • Power consumption at US
    typ. 1.8 W
  • Protective circuit/component
    Suppressor diode
  • Output name
    Enabling current path
  • Contact type
    2 enabling current paths
  • Current
    max. 100 mA
  • Typical release time at US
    25 ms (when actuation is via the sensor circuit)
  • Relay type
    Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
  • Assembly instructions
    See derating curve
  • Housing material
    PBT
  • Conductor cross section solid
    0.2 mm² ... 2.5 mm²
  • Stop category
    0
  • Category
    4 (5 A DC13; 5 A AC15; 8760 switching cycles/year)
  • Degree of pollution
    2
  • Depth
    114.5 mm
  • Max. permissible relative humidity (operation)
    75 % (on average, 85% infrequently, non-condensing)
  • Rated control circuit supply voltage US
    24 V DC -15 % / +10 % (provide external protection)
  • Protective circuit
    Serial protection against polarity reversal Suppressor diode
  • Input voltage range "1" signal
    20.4 V DC ... 26.4 V DC
  • Output description
    PNP
  • Contact material
    AgSnO2
  • Mechanical service life
    10x 106 cycles
  • Typical pickup time at US
    200 ms (when controlled via A1)
  • Maximum inrush current
    500 mA (Δt = 1 ms at Us)
  • Restart time
    < 1 s (Boot time)
  • Mounting position
    vertical or horizontal
  • Min. degree of protection of inst. location
    IP54
  • pluggable
    no
  • Conductor cross-section AWG
    24 ... 16
  • Stripping length
    10 mm
  • Safety Integrity Level Claim Limit (SIL CL)
    3
  • ECLASS 10.0.1
    27371819
  • ETIM 6.0
    EC001449
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Maximum altitude
    ≤ 2000 m (Above sea level)
  • Filter time
    No darkness test pulses / low test pulses permitted. No brightness test pulses / high test pulses permitted.
  • Current consumption
    typ. 10 mA (Typically with US at Y1)
  • Number of outputs
    1
  • Sq. Total current
    72 A2 (observe derating)
  • Switching capacity
    min. 100 mW
  • Switching capacity according to IEC 60947-5-1
    5 A (24 V (DC13))
  • Recovery time
    < 500 ms
  • Net weight
    169.38 g
  • Degree of protection
    IP20
  • Operating voltage display
    1 x green LED
  • Connection method
    Push-in connection
  • Performance level (PL)
    e
  • Standards/regulations
    DIN EN 50178
  • REACh SVHC
    Lead 7439-92-1
  • Nominal operating mode
    100% operating factor
  • Mounting type
    DIN rail mounting
  • Housing color
    yellow
  • Status display
    4 x green LEDs
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Safety Integrity Level (SIL)
    3
  • Shock
    15g
  • Vibration (operation)
    10 Hz ... 150 Hz, 2g
  • ETIM 7.0
    EC001449
  • ECLASS 11.0
    27371819

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.

This item can ship within 24h!

1-year warranty

$313.80

1009832

Stock:

1

Select Qty:

$313.80

$313.80 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo