8086610 Festo Electrical Peripheral Devices

Festo 8086610 EtherNet/IP interface CPX-AP-I-EP-M12 Dimensions W x L x H: 45 mm x 170 mm x 35 mm, Diagnostics via LED: (* Diagnostics per module, * Network status EtherNet/IP, * Power supply electronics/sensors, * Power supply load, * System diagnostics, * Maintenance
Festo

Part#:8086610

Manufacturer:Festo

Alt. Part#:CPX-AP-I-EP-M12

Product Lifecycle:Active

Get a quick Quote!

About the product: EtherNet/IP interface CPX-AP-I-EP-M12 Dimensions W x L x H: 45 mm x 170 mm x 35 mm, Diagnostics via LED: (* Diagnostics per module, * Network status EtherNet/IP, * Power supply electronics/sensors, * Power supply load, * System diagnostics, * Maintenance

About the manufacturer: Festo is one of the manufacturers that offers Electrical Peripheral Devices that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8086610 Festo price in the box on the right side or send a quick quote.

8086610 Product Details

  • Fieldbus interface, connection technology
    M12x1, D-coded as per EN 61076-2-101
  • Note on degree of protection
    Unused connections sealed
  • Intrinsic current consumption at nominal operating voltage load
    Typically 5 mA
  • Information on max. cable length
    Power supply according to nominal voltage
  • Power supply, type of connection
    Plug
  • Diagnostics via LED
    Diagnostics per module Maintenance required
  • Fieldbus interface, number of poles/wires
    4
  • Max. address capacity outputs
    1324 byte
  • Power failure buffering
    10 ms
  • CE marking (see declaration of conformity)
    As per EU EMC directive
  • Degree of protection
    IP65 IP67
  • Housing material
    PA Die-cast zinc, nickel-plated
  • Permissible voltage fluctuations for electronics/sensors
    ± 25 %
  • Fieldbus interface, connection type
    2x socket
  • Diagnostics via bus
    Load switch-off Communication with AP module interrupted
  • Communication interface, function
    System communication XF20 OUT / XF21 OUT
  • Max. cable length
    50 m system communication
  • Communication interface, shielding
    yes
  • Power supply, number of pins/wires
    4
  • Max. number of modules
    80
  • Corrosion resistance class (CRC)
    1 - Low corrosion stress
  • Type of mounting
    With through-hole
  • Dimensions W x L x H
    45 mm x 170 mm x 35 mm
  • Max. power supply
    2 x 4 A (external fuse required)
  • Communication interface, connection technology
    M8x1, D-coded as per EN 61076-2-114
  • Voltage forwarding, connection technology
    M8x1, A-coded as per EN 61076-2-104
  • Communication interface, connection type
    2x socket
  • Fieldbus interface, protocol
    EtherNet/IP
  • Permissible voltage fluctuations load
    ± 25 %
  • Nominal operating voltage DC for electronics/sensors
    24 V
  • Communication interface, number of pins/wires
    4
  • Product weight
    194 g
  • Diagnose per internal communication
    Module error Load supply undervoltage
  • Fieldbus interface, type
    Ethernet
  • Power supply, function
    Incoming electronics/sensors and load
  • Fieldbus interface, galvanic isolation
    yes
  • Voltage forwarding, connection type
    Socket
  • Configuration support
    EDS file
  • Fieldbus interface, transmission rate
    100 Mbit/s
  • Voltage forwarding, number of pins/wires
    4
  • Max. address capacity inputs
    1324 byte
  • Reverse polarity protection
    yes
  • Type code
    CPX-AP-I
  • Ambient temperature
    -20 °C ... 50 °C
  • Note on materials
    RoHS-compliant
  • KC characters
    KC EMC
  • Power supply, connection technology
    M8x1, A-coded as per EN 61076-2-104
  • Fieldbus interface, function
    Bus connection, incoming/forwarding
  • Relative air humidity
    5 - 95 % Non-condensing
  • Intrinsic current consumption at nominal operating voltage for electronics/sensors
    Typically 90 mA
  • Communication interface, protocol
    AP-COM
  • Voltage forwarding, function
    Outgoing electronics/sensors and load
  • Nominal operating voltage DC load
    24 V
  • Note regarding operating voltage
    SELV/PELV fixed power supplies required Note voltage drop
  • Storage temperature
    -40 °C ... 70 °C
  • Certification
    RCM compliance mark

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8086610 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

8086610

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty