Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

8036884 Festo Flow Sensors

Festo 8036884 flow sensor SFAW-32T-CS515-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to Ro
Festo

Part#:8036884

Manufacturer:Festo

Alt. Part#:SFAW-32T-CS515-E-PNLK-PNVBA-M12

Product Lifecycle:Active

Get a quick Quote!

About the product: flow sensor SFAW-32T-CS515-E-PNLK-PNVBA-M12 Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to EU directive for EMC, * in accordance with EU RoHS directive), KC mark: KC-EMV, Materials note: Conforms to Ro

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8036884 Festo price in the box on the right side or send a quick quote.

8036884 Product Details

  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Note on materials
    RoHS-compliant
  • Temperature measuring range start value
    0 °C
  • Nominal temperature
    23 °C
  • Repetition accuracy of flow rate value
    < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS
  • Temperature co-efficient margin in ± %FS/K
    Typ. ±0.05% FS/K
  • Temperature characteristic curve start value
    0 °C
  • Short-circuit protection
    yes
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, service data contents IN
    32 bit volume measurement
  • Max. cable length
    20 m for IO-Link® operation 30 m
  • Product weight
    400 g
  • Type code
    SFAW
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Flow direction
    Unidirectional P1 -> P2
  • Flow measuring range end value
    32 l/min
  • Information on operating pressure
    Max. 12 bar at 40°C Max. 6 bar at 100 °C
  • Temperature of medium
    0 °C ... 90 °C
  • Ambient temperature
    0 °C ... 50 °C
  • Switching function
    Window comparator Freely programmable
  • Switching element function
    N/C contact/N/O contact switchable
  • Temperature characteristic curve end value
    100 °C
  • Protocol
    IO-Link®
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, process data content IN
    1 bit BDC (temperature monitoring) 2 bit BDC (flow monitoring)
  • IO-Link®, data memory required
    500 byte
  • Symbol
    00995566
  • Method of measurement
    Flow rate: vortex Temperature: PT1000
  • Temperature measuring range end value
    90 °C
  • Accuracy of flow rate
    ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS
  • Analog output
    0 - 10 V 1 - 5 V
  • Max. load resistance of current output
    500 Ohm
  • IO-Link®, port class
    A
  • Electrical connection
    5-pin Plug, straight
  • DC operating voltage range
    18 V ... 30 V
  • Materials in contact with the media
    EPDM (peroxide) PA6T/6I-reinforced
  • Operating pressure
    0 bar ... 12 bar
  • Operating medium
    Liquid media Neutral liquids
  • Accuracy of temperature in ± °C
    2 °C
  • Max. output current
    100 mA
  • Flow characteristic curve, start value
    0 l/min
  • Min. load resistance of voltage output
    15 kOhm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, process data width IN
    5 Byte
  • IO-Link®, minimum cycle time
    5 ms
  • Mounting position
    Any
  • Corrosion resistance class (CRC)
    3 - High corrosion stress
  • KC characters
    KC EMC
  • Measured variable
    Flow rate Temperature
  • Flow measuring range start value
    1.8 l/min
  • Information on operating and pilot media
    Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured.
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Flow characteristic curve, end value
    32 l/min
  • Overload protection
    Available
  • IO-Link®, process data width OUT
    0 Byte
  • Reverse polarity protection
    for all electrical connections
  • Fluid connector
    Terminal connection DIN 32676 DN10
  • Displayable unit(s)
    US gal °F
  • Housing material
    PA-reinforced
  • Degree of protection
    IP65

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8036884 Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

8036884

Select Qty:

Average response time: 11 minutes

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo