8036878 Festo Flow Sensors

Festo 8036878 flow sensor SFAW-100T-TG1-E-PNLK-PNVBA-M12 For measuring and monitoring flow rate, volume and temperature of liquid media, flow measuring range 100l/min. Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to
Festo

Part#:8036878

Manufacturer:Festo

Alt. Part#:SFAW-100T-TG1-E-PNLK-PNVBA-M12

Product Lifecycle:Active

In-stock parts: 2

04/20/2024

About the product: flow sensor SFAW-100T-TG1-E-PNLK-PNVBA-M12 For measuring and monitoring flow rate, volume and temperature of liquid media, flow measuring range 100l/min. Authorisation: (* RCM Mark, * c UL us - Listed (OL)), CE mark (see declaration of conformity): (* to

About the manufacturer: Festo is one of the manufacturers that offers Flow Sensors that you can order at Quotebeam.com. Festo Corp. has been a top supplier of automation and intelligent automation solutions for more than four decades in the United States and eight decades globally. The company is committed to transforming the manufacturing sector and enhancing business efficiency.

Check out the 8036878 Festo price in the box on the right side or send a quick quote.

8036878 Product Details

  • Note on materials
    RoHS-compliant
  • Flow measuring range start value
    5 l/min
  • Operating medium
    Liquid media Neutral liquids
  • Temperature co-efficient margin in ± %FS/K
    Typ. ±0.05% FS/K
  • Switching element function
    N/C contact/N/O contact switchable
  • Flow characteristic curve, start value
    0 l/min
  • Protocol
    IO-Link®
  • IO-Link®, function classes
    Binary data channel (BDC) Teach channel
  • IO-Link®, service data contents IN
    32 bit volume measurement
  • IO-Link®, process data width IN
    5 Byte
  • Mounting position
    Any
  • Degree of protection
    IP65
  • CE marking (see declaration of conformity)
    As per EU EMC directive As per EU RoHS directive
  • Method of measurement
    Flow rate: vortex Temperature: PT1000
  • Information on operating and pilot media
    Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured.
  • Accuracy of temperature in ± °C
    2 °C
  • Analog output
    0 - 10 V 1 - 5 V
  • Temperature characteristic curve end value
    100 °C
  • IO-Link®, profile
    Smart sensor profile
  • IO-Link®, port class
    A
  • IO-Link®, data memory required
    500 byte
  • DC operating voltage range
    18 V ... 30 V
  • Housing material
    PA-reinforced
  • Symbol
    00995566
  • Measured variable
    Flow rate Temperature
  • Temperature measuring range start value
    0 °C
  • Ambient temperature
    0 °C ... 50 °C
  • Repetition accuracy of flow rate value
    < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS
  • Switching function
    Window comparator Freely programmable
  • Min. load resistance of voltage output
    15 kOhm
  • Max. load resistance of current output
    500 Ohm
  • IO-Link®, protocol version
    Device V 1.1
  • IO-Link®, minimum cycle time
    5 ms
  • Max. cable length
    20 m for IO-Link® operation 30 m
  • Product weight
    400 g
  • Type code
    SFAW
  • Flow direction
    Unidirectional P1 -> P2
  • Temperature measuring range end value
    90 °C
  • Information on operating pressure
    Max. 12 bar at 40°C Max. 6 bar at 100 °C
  • Nominal temperature
    23 °C
  • Switching output
    2 x PNP or 2 x NPN switchable
  • Flow characteristic curve, end value
    100 l/min
  • Short-circuit protection
    yes
  • IO-Link®, communication mode
    COM2 (38,4 kBd)
  • IO-Link®, process data width OUT
    0 Byte
  • Reverse polarity protection
    for all electrical connections
  • Materials in contact with the media
    EPDM (peroxide) PA6T/6I-reinforced
  • Corrosion resistance class (CRC)
    3 - High corrosion stress
  • KC characters
    KC EMC
  • Certification
    RCM compliance mark c UL us - Listed (OL)
  • Flow measuring range end value
    100 l/min
  • Operating pressure
    0 bar ... 12 bar
  • Temperature of medium
    0 °C ... 90 °C
  • Accuracy of flow rate
    ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS
  • Max. output current
    100 mA
  • Temperature characteristic curve start value
    0 °C
  • Overload protection
    Available
  • IO-Link®, SIO mode support
    Yes
  • IO-Link®, process data content IN
    1 bit BDC (temperature monitoring) 2 bit BDC (flow monitoring)
  • Electrical connection
    5-pin Plug, straight
  • Fluid connector
    Internal thread G1
  • Displayable unit(s)
    US gal °F

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used surplus in original packaging with original factory seal.


Related documents 8036878 Specs

This item can ship within 24h!

1-year warranty

$721.28

8036878

Stock:

2

Select Qty:

$721.28

$721.28 each

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo