Nikki Gonzales
Nick Goetz
Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

X20ATB312 B&R Electronic Components

B&R X20ATB312 X20 temperature input module, 4 resistance measurement inputs, Pt100, resolution 0.01°C, 4-wire connections, NetTime function
B&R

Part#:X20ATB312

Manufacturer:B&R

Product Lifecycle:Active

Get a quick Quote!

X20 temperature input module, 4 resistance measurement inputs, Pt100, resolution 0.01°C, 4-wire connections, NetTime function

Check out the X20ATB312 B&R price in the box on the right side or send a quick quote.

Product Details

  • Temperature Operation Vertical mounting orientation
    -25 to 50°C
  • Relative humidity Transport
    5 to 95%, non-condensing
  • Relative humidity Operation
    5 to 95%, non-condensing
  • Temperature Storage
    -40 to 85°C
  • Temperature Operation Horizontal mounting orientation
    -25 to 60°C
  • Relative humidity Storage
    5 to 95%, non-condensing
  • Mounting orientation Vertical
    Yes
  • Temperature Transport
    -40 to 85°C
  • Temperature Derating
    -
  • Installation elevation above sea level >2000 m
    Reduction of ambient temperature by 0.5°C per 100 m
  • Installation elevation above sea level 0 to 2000 m
    No limitation
  • Resistance measurement monitoring Range overshoot
    0xFFFFFFFF
  • Resistance measurement monitoring General fault
    0x80000000
  • Resistance measurement monitoring Range undershoot
    0x80000001
  • Mounting orientation Horizontal
    Yes
  • Temperature measurement monitoring Open inputs
    0x7FFFFFFF
  • Resistance measurement monitoring Open circuit
    0xFFFFFFFF
  • Temperature measurement monitoring Open circuit
    0x7FFFFFFF
  • Temperature measurement monitoring General fault
    0x80000000
  • Temperature measurement monitoring Range undershoot
    0x80000001
  • Temperature measurement monitoring Range overshoot
    0x7FFFFFFF
  • Max. error at 25°C Offset
    0.0015%
  • Max. error at 25°C Gain
    0.0059%
  • Conversion time 1 channel
    20 ms with 50 Hz filter
  • Certifications EAC
    Yes
  • Conversion time 2 channels
    40 ms per channel with 50 Hz filter
  • Certifications LR
    ENV1
  • Certifications DNV
    Temperature: B (0 - 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
  • Certifications ATEX
    Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
  • Certifications UL
    cULus E115267; Industrial control equipment
  • Certifications HazLoc
    cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
  • Certifications CE
    Yes
  • Power consumption Bus
    0.01 W
  • Note
    Order 1x terminal block X20TB1F separately.; Order 1x bus module X20BM11 separately.
  • Power consumption Internal I/O
    0.5 W (Rev. ≥ D0), 0.6 W (Rev. < D0)
  • Certifications UKCA
    Yes
  • Diagnostics Inputs
    Yes, using LED status indicator and software
  • Electrical isolation
    Channel isolated from bus; Channel not isolated from channel
  • Diagnostics Module run/error
    Yes, using LED status indicator and software
  • Degree of protection per EN 60529
    IP20
  • Pitch
    12.5+0.2 mm
  • Nonlinearity
    <0.001%
  • Standardized range of values for resistance measurement
    19 to 390 Ω
  • Reference
    1568 Ω ±0.1%
  • Max. offset drift
    <0.000025%/°C
  • Temperature sensor normalization
    -200.0 to 850.0°C
  • Permissible input signal
    Short-term max. 28.8 V
  • Max. gain drift
    <0.00065%/°C
  • Insulation voltage between channel and bus
    500 Veff
  • Measurement current
    1 mA
  • Linearization method
    Internal
  • Resistance measurement resolution
    0.001 Ω
  • Input filter
    First-order low-pass filter / cutoff frequency 1050 Hz
  • Sensor standard
    EN 60751
  • Temperature sensor resolution
    1 LSB = 0.01°C
  • Resistance measurement range
    0.5 to 390 Ω
  • Conversion procedure
    Sigma-delta
  • Filter time
    Configurable between 1 and 200 ms
  • B&R ID code
    0xE0EF
  • Input
    Resistance measurement with constant current supply for 4-wire connections
  • Output format
    DINT or UDINT for resistance measurement
  • Temperature measurement range
    -200 to 850°C
  • Status indicators
    I/O function per channel, operating state, module status
  • Digital converter resolution
    24-bit
  • I/O module
    4 inputs for Pt100 resistance temperature measurement

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of B&R

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

B&R Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many B&R Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from B&R, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo