Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

LC1D32P7 Schneider Electric Industrial Automation Components

Schneider Electric LC1D32P7 Schneider Electric LC1D32P7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 50A (AC-1) and 32A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 184-253Vac (230Vac nom.; 50Hz; 0.8...1.1 x Uc) to 195.5-253Vac (230Vac nom.; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 7.5kW at 220-230Vac to 18.5kW at 660-690Vac (AC-3). The rated power (HP) ranges from 2HP at 115Vac to 25HP at 575-600Vac, with mechanical durability of 15,000,000 operations and electrical durability of 1,600,000 operations at load. The rated voltage (AC) phase-to-phase is 690 V.
Schneider Electric

Part#:LC1D32P7

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Schneider Electric LC1D32P7 is a magnetic contactor from the Deca sub-range, featuring screw connections and designed with 3 poles (3P; 3NO). It has a rated current of 50A (AC-1) and 32A (440Vac; AC-3), with a mounting mode suitable for DIN rail installation. The net width of the contactor is 45 mm, and it offers a degree of protection rated at IP20. The control voltage (AC) ranges from 184-253Vac (230Vac nom.; 50Hz; 0.8...1.1 x Uc) to 195.5-253Vac (230Vac nom.; 60Hz; 0.85...1.1 x Uc), with a rated operating voltage (Ue) of 690 V. It includes 1 Normally Open (NO) auxiliary contact and 1 Normally Closed (NC) auxiliary contact, with contacts type of 1NO+1NC instantaneous aux. The rated impulse voltage (Uimp) is 6 kV, and the rated active power (kW) spans from 7.5kW at 220-230Vac to 18.5kW at 660-690Vac (AC-3). The rated power (HP) ranges from 2HP at 115Vac to 25HP at 575-600Vac, with mechanical durability of 15,000,000 operations and electrical durability of 1,600,000 operations at load. The rated voltage (AC) phase-to-phase is 690 V.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the LC1D32P7 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Product Certifications
    UL GOST CSA BV LROS (Lloyds register of shipping) RINA GL CCC DNV
  • Motor Power HP (UL / CSA)
    5 hp 230/240 V at AC 50/60 Hz for 1 phase 10 hp 230/240 V at AC 50/60 Hz for 3 phase 30 hp 575/600 V at AC 50/60 Hz for 3 phase 2 hp 115 V at AC 50/60 Hz for 1 phase 7.5 hp 200/208 V at AC 50/60 Hz for 3 phase 20 hp 460/480 V at A
  • Standards
    CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508
  • [Icw] Rated Short-Time Withstand Current
    60 A 104 °F (40 °C) - 10 min power circuit 138 A 104 °F (40 °C) - 1 min power circuit 260 A 104 °F (40 °C) - 10 s power circuit 430 A 104 °F (40 °C) - 1 s power circuit 100 A - 1 s signalling circuit 120 A - 500 ms signalling circ
  • Motor Power Kw
    7.5 kW 220...230 V AC 50/60 Hz AC-3) 15 kW 380...400 V AC 50/60 Hz AC-3) 15 kW 415...440 V AC 50/60 Hz AC-3) 18.5 kW 500 V AC 50/60 Hz AC-3) 18.5 kW 660...690 V AC 50/60 Hz AC-3) 7.5 kW 400 V AC 50/60 Hz AC-4)
  • [Ui] Rated Insulation Voltage
    Power circuit 600 V CSA Power circuit 600 V UL Signalling circuit 690 V IEC 60947-1 Signalling circuit 600 V CSA Signalling circuit 600 V UL Power circuit 690 V IEC 60947-4-1
  • Control Circuit Voltage Limits
    0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz
  • Tightening Torque
    Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat Ø 6 mm Power circuit 22.13 lb
  • Irms Rated Making Capacity
    140 A AC signalling circuit IEC 60947-5-1 250 A DC signalling circuit IEC 60947-5-1 550 A 440 V power circuit IEC 60947
  • Utilisation Category
    AC-1 AC-3 AC-4
  • Associated Fuse Rating
    10 A gG signalling circuit IEC 60947-5-1 63 A gG <= 690 V type 1 power circuit 63 A gG <= 690 V type 2 power circuit
  • Auxiliary Contacts Type
    Mechanically linked 1 NO + 1 NC IEC 60947-5-1 Mirror contact 1 NC IEC 60947-4-1
  • Inrush Power In VA
    70 VA 60 Hz 0.75 68 °F (20 °C)) 70 VA 50 Hz 0.75 68 °F (20 °C))
  • Hold-In Power Consumption In VA
    7.5 VA 60 Hz 0.3 68 °F (20 °C)) 7 VA 50 Hz 0.3 68 °F (20 °C))
  • Non-Overlap Time
    1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
  • [Ie] Rated Operational Current
    32 A 140 °F (60 °C)) <= 440 V AC AC-3 power circuit 50 A 140 °F (60 °C)) <= 440 V AC AC-1 power circuit
  • Mounting Support
    Rail Plate
  • Safety Reliability Level
    B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
  • [Ue] Rated Operational Voltage
    Power circuit <= 690 V AC 25...400 Hz Power circuit <= 300 V DC
  • [Ith] Conventional Free Air Thermal Current
    10 A 140 °F (60 °C) signalling circuit 50 A 140 °F (60 °C) power circuit
  • Power Dissipation Per Pole
    2 W AC-3 5 W AC-1
  • Operating Time
    4...19 ms opening 12...22 ms closing
  • Electrical Durability
    1.65 Mcycles 32 A AC-3 <= 440 V 1.4 Mcycles 50 A AC-1 <= 440 V
  • Contactor Application
    Resistive load Motor control
  • Connections - Terminals
    Control circuit screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)fle
  • Insulation Resistance
    > 10 MOhm signalling circuit
  • Minimum Switching Current
    5 mA signalling circuit
  • Signalling Circuit Frequency
    25...400 Hz
  • Minimum Switching Voltage
    17 V signalling circuit
  • Heat Dissipation
    2…3 W 50/60 Hz
  • Maximum Operating Rate
    3600 cyc/h 140 °F (60 °C)
  • Coil Technology
    Without built-in suppressor module
  • Mechanical Durability
    15 Mcycles
  • Front Cover
    With
  • Average Impedance
    2 mOhm - Ith 50 A 50 Hz power circuit
  • Rated Breaking Capacity
    550 A 440 V power circuit IEC 60947
  • [Uimp] Rated Impulse Withstand Voltage
    6 kV IEC 60947
  • Auxiliary Contact Composition
    1 NO + 1 NC
  • Overvoltage Category
    III
  • [Uc] Control Circuit Voltage
    230 V AC 50/60 Hz
  • Control Circuit Type
    AC 50/60 Hz
  • Poles Description
    3P
  • Power Pole Contact Composition
    3 NO
  • Device Short Name
    LC1D
  • Product Name
    TeSys D
  • Product Or Component Type
    Contactor
  • Range
    TeSys

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo