JDA262502 Schneider Electric Industrial Automation Components

Schneider Electric JDA262502 Square D by Schneider Electric JDA262502 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JDA sub-range, featuring a PowerPact J-Frame 250 TMD 2P 250A 600Vac 14kA I-line AC 80% rated design. It is equipped with a 2-pole (2P) configuration and offers thermal protection for overload and magnetic protection for short-circuit scenarios. The breaker has a rated current of 250A, with a rated insulation voltage (Ui) of 750 V and a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism, ensuring a robust attachment. The unit's dimensions include a net height of 191 mm, a net width of 105 mm, and a net depth of 127 mm, and it provides a degree of protection of IP40. The operating mode is manual toggle, with protection settings for over-current fixed at 250A and short-circuit pickup current adjustable between 1250A and 2500A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 250 AT, and the frame current rating is 250 AF. Its short circuit breaking rating varies according to voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) without a display, and it falls under utilisation category A.
Schneider Electric

Part#:JDA262502

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Square D by Schneider Electric JDA262502 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JDA sub-range, featuring a PowerPact J-Frame 250 TMD 2P 250A 600Vac 14kA I-line AC 80% rated design. It is equipped with a 2-pole (2P) configuration and offers thermal protection for overload and magnetic protection for short-circuit scenarios. The breaker has a rated current of 250A, with a rated insulation voltage (Ui) of 750 V and a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism, ensuring a robust attachment. The unit's dimensions include a net height of 191 mm, a net width of 105 mm, and a net depth of 127 mm, and it provides a degree of protection of IP40. The operating mode is manual toggle, with protection settings for over-current fixed at 250A and short-circuit pickup current adjustable between 1250A and 2500A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 250 AT, and the frame current rating is 250 AF. Its short circuit breaking rating varies according to voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) without a display, and it falls under utilisation category A.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the JDA262502 Schneider Electric price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


JDA262502 Description

Square D by Schneider Electric JDA262502 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT JDA sub-range, featuring a PowerPact J-Frame 250 TMD 2P 250A 600Vac 14kA I-line AC 80% rated design. It is equipped with a 2-pole (2P) configuration and offers thermal protection for overload and magnetic protection for short-circuit scenarios. The breaker has a rated current of 250A, with a rated insulation voltage (Ui) of 750 V and a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mounting on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism, ensuring a robust attachment. The unit's dimensions include a net height of 191 mm, a net width of 105 mm, and a net depth of 127 mm, and it provides a degree of protection of IP40. The operating mode is manual toggle, with protection settings for over-current fixed at 250A and short-circuit pickup current adjustable between 1250A and 2500A. The rated operating voltage (Ue) is 690 V, with a rated impulse voltage (Uimp) of 8 kV. The trip current rating is 250 AT, and the frame current rating is 250 AF. Its short circuit breaking rating varies according to voltage, with 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Vac and 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (adjustable) without a display, and it falls under utilisation category A.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo