Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

BJL16060 Schneider Electric Industrial Automation Components

Schneider Electric BJL16060 Square D by Schneider Electric BJL16060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 60A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 60A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or individually on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 60 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric

Part#:BJL16060

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Square D by Schneider Electric BJL16060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 60A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 60A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 15,000 operations at no load and can be mounted on a DIN rail or individually on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 60 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all in accordance with UL489. The trip unit type is thermal-magnetic (fixed) with no display.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BJL16060 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Breaking Capacity
    100 kA 208Y/120 V AC 50/60 Hz UL 489 100 kA 240 V AC 50/60 Hz UL 489 65 kA 480Y/277 V AC 50/60 Hz UL 489 25 kA 600Y/347 V AC 50/60 Hz UL 489 50 kA 125 V DC UL 489
  • [Ue] Rated Operational Voltage
    240 V AC 50/60 Hz UL 489 AC DC
  • Electrical Connection
    Everlink lug line Everlink lug load
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • AWG Gauge
    AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Mounting Mode
    Clip-on 35 mm symmetrical DIN rail) By screws plate)
  • 9 Mm Pitches
    3
  • Quantity Per Set
    Set of 1
  • Net Weight
    1.12 lb(US) (0.51 kg)
  • Depth
    3.15 in (80 mm)
  • Color
    Grey (RAL 7016)
  • Width
    1.06 in (27 mm)
  • Height
    5.39 in (137 mm)
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Utilisation Category
    Category A
  • Connection Pitch
    1.06 in (27 mm)
  • Mechanical Durability
    15000 cycles IEC 947-1 Annex F ed 5.2
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 In
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • Trip Unit Name
    TM-D
  • Breaking Capacity Code
    J
  • Trip Unit Technology
    Thermal-magnetic
  • Continuous Current Rating
    80 %
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • [Ics] Rated Service Breaking Capacity
    65 kA 220...240 V AC 50/60 Hz IEC 60947-2
  • Line Rated Current
    60 A
  • Number Of Poles
    1P
  • Control Type
    Toggle
  • Protected Poles Description
    1t
  • Device Short Name
    BJ 060
  • Device Application
    Distribution
  • Product Or Component Type
    Circuit breaker
  • Range
    PowerPact
  • Product Name
    PowerPact B

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

This item can ship within 24h!

BJL36030 Part Image. Manufactured by Schneider Electric.

BJL36030

$1,129.20

Verified stock: 3

Square D by Schneider Electric BJL36030 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 3P 30A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection rated at IP40. The breaker is designed for a rated current of 30A and a rated voltage (AC) of 600Vac 600Y/347Vac, with mechanical durability rated for 20,000 operations at no load. It can be mounted on a DIN rail or as an individual unit on a plate, featuring 3 poles (3P) and dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. The utilisation category is A, with protection settings including over-current fixed at 30A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 30 AT and electrical durability (with load) of 10,000 operations at 440Vac; In. The frame current rating is 100 AF, operated by a toggle (manual) mode, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BJL26050 Part Image. Manufactured by Schneider Electric.

BJL26050

Verified stock: 0

Square D by Schneider Electric BJL26050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJL sub-range, featuring a PowerPact B-Frame 100 TMD 2P 50A 600Y/347Vac 25kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 50A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and can be mounted on a DIN rail or as an individual unit on a plate. This 2-pole (2P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 50 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo