BJA261101 Schneider Electric Molded Case Circuit Breakers (MCCB)

Schneider Electric BJA261101 Square D by Schneider Electric BJA261101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 125 TMD 2P 110A design for 600Y/347Vac with a 25kA I-line AB 80% rating. It has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection (AB phases) with an IP40 degree of protection. The rated current is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 2-pole (2P) breaker has dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width, falling under the utilisation category A. Its protection settings include over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT and an electrical durability of 10,000 operations with load at 440Vac; In. The frame current rating is 125 AF, operated by a toggle (manual) with a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489, including 50kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric

Part#:BJA261101

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Square D by Schneider Electric BJA261101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 125 TMD 2P 110A design for 600Y/347Vac with a 25kA I-line AB 80% rating. It has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection (AB phases) with an IP40 degree of protection. The rated current is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 2-pole (2P) breaker has dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width, falling under the utilisation category A. Its protection settings include over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT and an electrical durability of 10,000 operations with load at 440Vac; In. The frame current rating is 125 AF, operated by a toggle (manual) with a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489, including 50kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Molded Case Circuit Breakers (MCCB) that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BJA261101 Schneider Electric price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


BJA261101 Description

Square D by Schneider Electric BJA261101 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 125 TMD 2P 110A design for 600Y/347Vac with a 25kA I-line AB 80% rating. It has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection (AB phases) with an IP40 degree of protection. The rated current is 110A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It boasts a mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 2-pole (2P) breaker has dimensions of 137 mm in height, 89 mm in depth, and 54 mm in width, falling under the utilisation category A. Its protection settings include over-current fixed at 110A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT and an electrical durability of 10,000 operations with load at 440Vac; In. The frame current rating is 125 AF, operated by a toggle (manual) with a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489, including 50kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

This item can ship within 24h!

BJA36060 Part Image. Manufactured by Schneider Electric.

BJA36060

$921.60

Verified stock: 75

Square D by Schneider Electric BJA36060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 60A 600Y/347Vac 25kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases with a degree of protection rated at IP40. The rated current is 60A, with an AC rated voltage of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It features 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. The utilisation category is A, and it offers protection settings including over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 60 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

This item can ship within 24h!

BJA36030 Part Image. Manufactured by Schneider Electric.

BJA36030

$921.60

Verified stock: 48

Square D by Schneider Electric BJA36030 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 30A 600Y/347Vac 25kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. The degree of protection is IP40, with a rated current of 30A and a rated voltage (AC) of 600Vac 600Y/347Vac. Its mechanical durability is rated at 20,000 operations at no load, and it is designed to mount on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A. Protection settings include over-current fixed at 30A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 30 AT. Its electrical durability with load is 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mechanism. The short circuit breaking rating includes 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards, with a 50kA rating at 250Vdc. The trip unit type is thermal-magnetic (fixed) without a display.

Schneider Electric

This item can ship within 24h!

BJA36040 Part Image. Manufactured by Schneider Electric.

BJA36040

$921.60

Verified stock: 20

Square D by Schneider Electric BJA36040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 40A 600Y/347Vac 25kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases with a degree of protection rated at IP40. The rated current is 40A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. It features 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. The utilisation category is A. Protection settings include over-current fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions cover thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 40 AT. Electrical durability with load is rated at 10,000 operations at 440Vac; In. The frame current rating is 100 AF, operating mode is toggle (manual), and the short circuit breaking rating varies with voltage, including 100kA at 240Vac, 65kA at 480Vac and 480Y/277Vac, 25kA at 600Y/347Vac, and 50kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

This item can ship within 24h!

BJA36125 Part Image. Manufactured by Schneider Electric.

BJA36125

$1,580.40

Verified stock: 19

Square D by Schneider Electric BJA36125 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BJA sub-range, featuring a PowerPact B-Frame 125 TMD 3P 125A design for 600Y/347Vac with a 25kA I-line ABC 80% rated. It has an 8 kV rated impulse voltage (Uimp) and utilizes an I-line connection for ABC phases. The degree of protection is IP40, with a rated current of 125A and a rated voltage of 600Vac 600Y/347Vac. It offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 690 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 125 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 125 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 100kA at 240Vac, 65kA at 480Vac, 65kA at 480Y/277Vac, and 25kA at 600Y/347Vac under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo