Square D by Schneider Electric BGL46060LU is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 100 TMD 4P 60A 600Y/347Vac 18kA design. It includes Everlink (Creep compensating) lugs on both line and load sides and a Control Wire terminal (CWT) on the line side only, offering a degree of protection of IP40. This MCCB has a rated current of 60A and operates at a rated voltage of 600Vac 600Y/347Vac, with a mechanical durability of 20,000 operations when mounted either on a DIN rail or as an individual unit on a plate. It has 4 poles (4P), with dimensions of 137 mm in height, 80 mm in depth, and 108 mm in width. The utilisation category is A, and it features over-current protection fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage for DC operations is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 60 AT and an electrical durability of 10,000 operations at 440Vac. The frame current rating is 100 AF, operated by a toggle (manual) with a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.
Check out the BGL46060LU Schneider Electric price in the box on the right side or send a quick quote.
Product Details
- Breaking Capacity 65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489
- [Ics] Rated Service Breaking Capacity 65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
- Number Of Slots 1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
- AWG Gauge AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
- Tightening Torque 44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
- Electrical Connection Everlink lug line Everlink lug load
- Mounting Mode Clip-on 35 mm symmetrical DIN rail) By screws plate)
- Quantity Per Set Set of 1
- Net Weight 3.18 lb(US) (1.441 kg)
- Depth 3.15 in (80 mm)
- Width 4.25 in (108 mm)
- Height 5.39 in (137 mm)
- 9 Mm Pitches 12
- Color Gray RAL 7016)
- Power Wire Stripping Length 0.79 in (20 mm)
- Local Signalling for presence of auxiliary contacts flag (green)
- Utilisation Category Category A
- Connection Pitch 1.06 in (27 mm)
- Electrical Durability 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Suitability For Isolation Yes conforming to IEC 60947-2
- Mechanical Durability 15000 cycles IEC 947-1 Annex K ed 5.2
- Trip Unit Technology Thermal-magnetic
- Trip Unit Name TM-D
- [Ui] Rated Insulation Voltage 800 V IEC 60947-2
- Continuous Current Rating 80 %
- [Ue] Rated Operational Voltage 525 V AC 50/60 Hz UL 489
- Breaking Capacity Code G
- [Uimp] Rated Impulse Withstand Voltage 8 kV IEC 60947-2
- Product Or Component Type Circuit breaker
- Product Name PowerPact B
- Range PowerPact
- Number Of Poles 4P
- Line Rated Current 60 A
- Control Type Toggle
- Device Short Name BG 060
- Protected Poles Description 4t
- Device Application Distribution
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents BGL46060LU Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Schneider Electric
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Schneider Electric Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨