Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

BGL36060 Schneider Electric Industrial Automation Components

Schneider Electric BGL36060 Square D by Schneider Electric BGL36060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range. It features a PowerPact B-Frame 100 TMD design with 3 poles (3P) and a rated current of 60A. This MCCB operates at a rated voltage of 600Vac 600Y/347Vac and a DC voltage of 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. The connection type is Everlink (Creep compensating) lugs on both line and load sides, offering a degree of protection of IP40. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 10,000 operations with load at 440Vac. The MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. It features over-current protection fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A, with a frame current rating of 100 AF. The protection functions include thermal protection (overload) and magnetic protection (short-circuit), with a trip current rating of 60 AT. The short circuit breaking rating varies with voltage, including 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it operates via a toggle (manual) mode.
Schneider Electric

Part#:BGL36060

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 4

Nov 23, 2024

Square D by Schneider Electric BGL36060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range. It features a PowerPact B-Frame 100 TMD design with 3 poles (3P) and a rated current of 60A. This MCCB operates at a rated voltage of 600Vac 600Y/347Vac and a DC voltage of 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. The connection type is Everlink (Creep compensating) lugs on both line and load sides, offering a degree of protection of IP40. It has a mechanical durability of 20,000 operations at no load and an electrical durability of 10,000 operations with load at 440Vac. The MCCB is designed for fixed mounting on DIN rail or as an individual unit mount on a plate, with dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. It features over-current protection fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A, with a frame current rating of 100 AF. The protection functions include thermal protection (overload) and magnetic protection (short-circuit), with a trip current rating of 60 AT. The short circuit breaking rating varies with voltage, including 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all under UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display, and it operates via a toggle (manual) mode.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BGL36060 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Breaking Capacity
    65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489
  • [Ics] Rated Service Breaking Capacity
    65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • AWG Gauge
    AWG 6...AWG 2/0 fine stranded aluminium/copper AWG 14...AWG 3/0 rigid or stranded aluminium/copper
  • Electrical Connection
    Everlink lug line Everlink lug load
  • Mounting Mode
    Clip-on 35 x 15 mm symmetrical DIN rail) By screws plate)
  • Height
    5.39 in (137 mm)
  • Net Weight
    2.37 lb(US) (1.074 kg)
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Quantity Per Set
    Set of 1
  • Depth
    3.15 in (80 mm)
  • 9 Mm Pitches
    9
  • Color
    Grey (RAL 7016)
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Width
    3.19 in (81 mm)
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Connection Pitch
    1.06 in (27 mm)
  • Mechanical Durability
    20000 cycles IEC 947-1 Annex K ed 5.2
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Utilisation Category
    Category A
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • [Ue] Rated Operational Voltage
    525 V AC 50/60 Hz UL 489
  • Continuous Current Rating
    80 %
  • Trip Unit Technology
    Thermal-magnetic
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Device Short Name
    BG 060
  • Breaking Capacity Code
    G
  • Control Type
    Toggle
  • Device Application
    Distribution
  • Product Or Component Type
    Circuit breaker
  • Product Name
    PowerPact B
  • Range
    PowerPact
  • Line Rated Current
    60 A
  • Number Of Poles
    3P

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



This item can ship within 24h!

1-year warranty

$900.00

Stock:

4

Select Qty:

$900.00

$900.00 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

This item can ship within 24h!

BGL36020 Part Image. Manufactured by Schneider Electric.

BGL36020

$900.00

Verified stock: 5

Square D by Schneider Electric BGL36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 100 TMD 3P 20A 600Y/347Vac 18kA design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes Everlink (Creep compensating) lugs for connections on both line and load sides, offering a degree of protection of IP40. The rated current is 20A, with a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB is designed for mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. It features 3 poles (3P), with dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. The utilisation category is A. Protection settings include over-current fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions cover thermal protection (Overload) and magnetic protection (Short-circuit), with a trip current rating of 20 AT. Electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and the operating mode is manual toggle. The short circuit breaking rating varies with voltage, including 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

This item can ship within 24h!

BGL36100 Part Image. Manufactured by Schneider Electric.

BGL36100

$1,081.20

Verified stock: 3

Square D by Schneider Electric BGL36100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 100 TMD 3P 100A 600Y/347Vac 18kA design. It is equipped with Everlink (Creep compensating) lugs on both line and load sides for connections and offers a degree of protection rated at IP40. The rated current is 100A, with a rated voltage (AC) of 600Vac 600Y/347Vac. It has a mechanical durability of 20,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 81 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 100 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies, with 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, and 18kA at 600Y/347Vac, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BGL16125 Part Image. Manufactured by Schneider Electric.

BGL16125

Verified stock: 0

Square D by Schneider Electric BGL16125 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGL sub-range, featuring a PowerPact B-Frame 125 TMD 1P-1t design. It has a rated current of 125A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is Everlink (Creep compensating) lugs on both line and load sides, offering a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 1-pole (1P) device with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. The utilisation category is A, and it features over-current protection fixed at 125A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC operations is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Its protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 125 AT. The electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 125 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo