Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

BGF26100 Schneider Electric Industrial Automation Components

Schneider Electric BGF26100 Square D by Schneider Electric BGF26100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design. It has a rated current of 100A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, offering a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It has 2 poles (2P) and falls under the utilization category A. The dimensions are 137 mm in height, 80 mm in depth, and 54 mm in width. Its protection settings include over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 100 AT. The electrical durability with load is 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual). The short circuit breaking rating varies with voltage: 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.
Schneider Electric

Part#:BGF26100

Manufacturer:Schneider Electric

Product Lifecycle:Active

Get a quick Quote!

Square D by Schneider Electric BGF26100 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design. It has a rated current of 100A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, offering a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It has 2 poles (2P) and falls under the utilization category A. The dimensions are 137 mm in height, 80 mm in depth, and 54 mm in width. Its protection settings include over-current fixed at 100A, short-circuit hold current fixed at 1000A, and short-circuit trip current fixed at 1500A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 100 AT. The electrical durability with load is 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual). The short circuit breaking rating varies with voltage: 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) without a display.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BGF26100 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • Breaking Capacity
    65 kA 208Y/120 V AC 50/60 Hz UL 489 65 kA 240 V AC 50/60 Hz UL 489 35 kA 480/277 V AC 50/60 Hz UL 489 35 kA 480 V AC 50/60 Hz UL 489 20 kA 250 V DC UL 489 18 kA 600Y/347 V AC 50/60 Hz UL 489
  • [Ics] Rated Service Breaking Capacity
    65 kA 220...240 V AC 50/60 Hz IEC 60947-2 18 kA 500...525 V AC 50/60 Hz IEC 60947-2 35 kA 380...415 V AC 50/60 Hz IEC 60947-2 35 kA 440 V AC 50/60 Hz IEC 60947-2
  • AWG Gauge
    AWG 14...AWG 8 aluminium/copper AWG 6...AWG 3/0 aluminium/copper
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in)
  • Tightening Torque
    44.25 lbf.in (5 N.m) 0.00…0.02 in² (2.5…16 mm²) (AWG 14...AWG 4) 79.66 lbf.in (9 N.m) 0.04…0.15 in² (25…95 mm²) (AWG 3...AWG 3/0)
  • Mounting Mode
    Clip-on 35 mm symmetrical DIN rail) By screws plate)
  • Quantity Per Set
    Set of 1
  • Depth
    3.15 in (80 mm)
  • Width
    2.13 in (54 mm)
  • Color
    Grey (RAL 7016)
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • 9 Mm Pitches
    6
  • Electrical Connection
    Terminal nut ON and OFF end
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • Suitability For Isolation
    Yes conforming to IEC 60947-2
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Connection Pitch
    1.06 in (27 mm)
  • Continuous Current Rating
    80 %
  • Product Name
    PowerPact B
  • Net Weight
    1.47 lb(US) (0.669 kg)
  • Height
    5.39 in (137 mm)
  • Mechanical Durability
    15000 cycles IEC 947-1 Annex K ed 5.2
  • Utilisation Category
    Category A
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Trip Unit Name
    TM-D
  • Trip Unit Technology
    Thermal-magnetic
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • Breaking Capacity Code
    G
  • [Ue] Rated Operational Voltage
    525 V AC 50/60 Hz UL 489
  • Protected Poles Description
    2t
  • Number Of Poles
    2P
  • Control Type
    Toggle
  • Device Application
    Distribution
  • Line Rated Current
    100 A
  • Product Or Component Type
    Circuit breaker
  • Device Short Name
    BG 100
  • Range
    PowerPact

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

BGF16025 Part Image. Manufactured by Schneider Electric.

BGF16025

Verified stock: 0

Square D by Schneider Electric BGF16025 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 1P-1t 25A 600Y/347Vac 18kA terminal nut 80% rated design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes a terminal nut kit for fixed busbar connection on both line and load sides. The degree of protection is IP40, with a rated current of 25A and a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB offers mechanical durability of 15,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 1-pole (1P) device with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. The utilisation category is A, and it provides protection settings including over-current fixed at 25A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 25 AT. Its electrical durability with load is 10,000 operations at 240Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BGF16040 Part Image. Manufactured by Schneider Electric.

BGF16040

Verified stock: 0

Square D by Schneider Electric BGF16040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, designed with a PowerPact B-Frame 100 TMD 1P-1t 40A 600Y/347Vac 18kA terminal nut 80% rated. It features a rated impulse voltage (Uimp) of 8 kV and utilizes a terminal nut kit for fixed busbar connection on both line and load sides. The device offers a degree of protection of IP40 and supports a rated current of 40A with a rated voltage (AC) of 600Vac 600Y/347Vac. It is built for mechanical durability up to 15,000 operations at no load and can be mounted either on a DIN rail or as an individual unit on a plate. This 1-pole (1P) circuit breaker has dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. It falls under utilisation category A and provides protection settings including over-current fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. It offers thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 40 AT. The electrical durability with load is rated for 10,000 operations at 240Vac; In, and the frame current rating is 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BGF26025 Part Image. Manufactured by Schneider Electric.

BGF26025

Verified stock: 0

Square D by Schneider Electric BGF26025 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 100 TMD 2P-2t design with a rated current of 25A and a rated voltage of 600Vac 600Y/347Vac. It has a rated impulse voltage (Uimp) of 8 kV and offers a connection via Term. nut kit for fixed busbar connection on both line and load sides. The degree of protection provided is IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 2-pole (2P) device with dimensions of 137 mm in height, 80 mm in depth, and 54 mm in width. The utilisation category is A. It features over-current protection fixed at 25A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage for DC applications is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 25 AT. Its electrical durability with load is rated at 10,000 operations at 440Vac. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage: 65kA at 240Vac, 35kA at 480Vac and 480Y/277Vac, and 18kA at 600Y/347Vac, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

BGF16110 Part Image. Manufactured by Schneider Electric.

BGF16110

Verified stock: 0

Square D by Schneider Electric BGF16110 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BGF sub-range, featuring a PowerPact B-Frame 125 TMD 1P-1t design. It has a rated current of 110A and operates at a rated voltage of 600Vac 600Y/347Vac, with a rated impulse voltage (Uimp) of 8 kV. The connection type is a terminal nut kit for fixed busbar connection on both line and load sides, and it offers a degree of protection of IP40. This MCCB has a mechanical durability of 15,000 operations and can be mounted either on a DIN rail or as an individual unit on a plate. It is a 1-pole (1P) device with dimensions of 137 mm in height, 80 mm in depth, and 27 mm in width. The utilisation category is A, and it features over-current protection fixed at 110A, short-circuit hold current protection fixed at 1000A, and short-circuit trip current protection fixed at 1500A. The rated voltage for DC applications is 125Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 240 V. It provides thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 110 AT. The electrical durability with load is 10,000 operations at 240Vac; In, and the frame current rating is 125 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 65kA at 240Vac, 35kA at 480Vac, 35kA at 480Y/277Vac, 18kA at 600Y/347Vac, and 20kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of: