Bryan Obida

Live support:

Monday - Friday 6AM - 6PM PST

BDA36020 Schneider Electric Industrial Automation Components

Schneider Electric BDA36020 Square D by Schneider Electric BDA36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 20A 600Y/347Vac 14kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. With a degree of protection rated at IP40, this MCCB has a rated current of 20A and supports a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20,000 operations at no load and offers a mounting mode that mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit features 3 poles (3P) and has dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and offers protection settings including over-current fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 20 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, offering 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac under UL489 standards, and 10kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.
Schneider Electric

Part#:BDA36020

Manufacturer:Schneider Electric

Product Lifecycle:Active

In-stock parts: 79

Nov 26, 2024

Square D by Schneider Electric BDA36020 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 20A 600Y/347Vac 14kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. With a degree of protection rated at IP40, this MCCB has a rated current of 20A and supports a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20,000 operations at no load and offers a mounting mode that mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism for robust attachment. The unit features 3 poles (3P) and has dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and offers protection settings including over-current fixed at 20A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 20 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In. The frame current rating is 100 AF, and it operates via a toggle (manual) mode. The short circuit breaking rating varies with voltage, offering 25kA at 240Vac, 18kA at 480Vac and 480Y/277Vac, 14kA at 600Y/347Vac under UL489 standards, and 10kA at 250Vdc. The trip unit type is thermal-magnetic (fixed) with no display.

About the manufacturer: Schneider Electric is one of the manufacturers that offers Industrial Automation Components that you can order at Quotebeam.com. We provide digital solutions for energy and automation that improve efficiency and support sustainability. Our comprehensive solutions include cutting-edge energy technologies, real-time automation, software, and services for residential, commercial, and industrial settings.

Check out the BDA36020 Schneider Electric price in the box on the right side or send a quick quote.

Product Details

  • TS PIK:
    109595297
  • Shipping Width:
    8.00 In.
  • Shipping Weight:
    4.25 lbs.
  • Shipping Length:
    13.00 In.
  • Shipping Height:
    5.00 In.
  • UPC:
    60648115251
  • Breaking Capacity
    25 kA 208Y/120 V AC 50/60 Hz UL 489 25 kA 240 V AC 50/60 Hz UL 489 18 kA 480/277 V AC 50/60 Hz UL 489 18 kA 480 V AC 50/60 Hz UL 489 14 kA 600Y/347 V AC 50/60 Hz UL 489 10 kA 250 V DC UL 489
  • [Ics] Rated Service Breaking Capacity
    25 kA 220...240 V AC 50/60 Hz IEC 60947-2 14 kA 500...525 V AC 50/60 Hz IEC 60947-2 18 kA 380...415 V AC 50/60 Hz IEC 60947-2 18 kA 440 V AC 50/60 Hz IEC 60947-2
  • Number Of Slots
    1 auxiliary switch OF plug-in) 1 voltage release MN or MX plug-in) 1 alarm switch SD plug-in)
  • Tightening Torque
    31.86…38.94 lbf.in (3.6…4.4 N.m) 0.00…0.01 in² (2.5…6 mm²) (AWG 14...AWG 10) 44.25…54.87 lbf.in (5…6.2 N.m) 0.02…0.11 in² (10…70 mm²) (AWG 8...AWG 2/0)
  • Electrical Connection
    I-Line connection line Lugs load
  • Phase Connection
    ABC
  • Depth
    3.50 in (89 mm)
  • Net Weight
    2.90 lb(US) (1.315 kg)
  • Quantity Per Set
    Set of 1
  • 9 Mm Pitches
    9
  • Width
    3.19 in (81 mm)
  • Height
    5.39 in (137 mm)
  • Color
    Grey (RAL 7016)
  • Power Wire Stripping Length
    0.79 in (20 mm)
  • Mounting Height
    4.49 in (114 mm)
  • Mounting Mode
    I-Line
  • Local Signalling
    for presence of auxiliary contacts flag (green)
  • AWG Gauge
    AWG 14...AWG 2/0 aluminium/copper
  • Electrical Durability
    10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
  • Mechanical Durability
    20000 cycles IEC 947-1 Annex K ed 5.2
  • Connection Pitch
    1.06 in (27 mm)
  • Utilisation Category
    Category A
  • [Uimp] Rated Impulse Withstand Voltage
    8 kV IEC 60947-2
  • [Ue] Rated Operational Voltage
    525 V AC 50/60 Hz UL 489
  • [Ui] Rated Insulation Voltage
    800 V IEC 60947-2
  • Suitability For Isolation
    Yes IEC 60947-2
  • Continuous Current Rating
    80 %
  • Trip Unit Technology
    Thermal-magnetic
  • Number Of Poles
    3P
  • Control Type
    Toggle
  • Breaking Capacity Code
    D
  • Line Rated Current
    20 A
  • Device Application
    Distribution
  • Device Short Name
    BD 020
  • Product Name
    PowerPact B
  • Range
    PowerPact
  • Product Or Component Type
    Circuit breaker

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



This item can ship within 24h!

1-year warranty

$718.80

Stock:

79

Select Qty:

$718.80

$718.80 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schneider Electric

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schneider Electric Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schneider Electric Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schneider Electric, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

This item can ship within 24h!

BDA36015 Part Image. Manufactured by Schneider Electric.

BDA36015

$718.80

Verified stock: 32

Square D by Schneider Electric BDA36015 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 15A 600Y/347Vac 14kA I-line design. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. The degree of protection is IP40, with a rated current of 15A and a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. It has 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. The utilisation category is A. Protection settings include over-current fixed at 15A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 525 V. Protection functions cover thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 15 AT. Electrical durability with load is 10,000 operations at 440Vac; In. The frame current rating is 100 AF, operating mode is toggle (manual), and the short circuit breaking rating varies from 25kA at 240Vac to 10kA at 250Vdc, according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

This item can ship within 24h!

BDA36040 Part Image. Manufactured by Schneider Electric.

BDA36040

$718.80

Verified stock: 24

Square D by Schneider Electric BDA36040 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 40A design for 600Y/347Vac with a 14kA I-line ABC 80% rated. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. This MCCB offers a degree of protection of IP40 and supports a rated current of 40A with a rated voltage (AC) of 600Vac 600Y/347Vac. It is designed for mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. The device has 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and features over-current protection fixed at 40A, short-circuit hold current fixed at 400A, and short-circuit trip current fixed at 600A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuits, with a trip current rating of 40 AT. Its electrical durability with load is rated for 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is manual toggle, and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac, 18kA at 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all according to UL489 standards. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

This item can ship within 24h!

BDA36050 Part Image. Manufactured by Schneider Electric.

BDA36050

$718.80

Verified stock: 26

Square D by Schneider Electric BDA36050 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 50A design for 600Y/347Vac with a 14kA I-line ABC 80% rated. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. The degree of protection is IP40, with a rated current of 50A and a rated voltage (AC) of 600Vac 600Y/347Vac. This MCCB offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. It has 3 poles (3P), with dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. The utilisation category is A, and it includes protection settings for over-current fixed at 50A, short-circuit hold current fixed at 480A, and short-circuit trip current fixed at 720A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 50 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac, 18kA at 480Y/277Vac, 14kA at 600Y/347Vac under UL489, and 10kA at 250Vdc under UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

This item can ship within 24h!

BDA36060 Part Image. Manufactured by Schneider Electric.

BDA36060

$718.80

Verified stock: 17

Square D by Schneider Electric BDA36060 is a Moulded Case Circuit Breaker (MCCB) within the PowerPacT BDA sub-range, featuring a PowerPact B-Frame 100 TMD 3P 60A design for 600Y/347Vac with a 14kA I-line and ABC 80% rated. It has a rated impulse voltage (Uimp) of 8 kV and utilizes an I-line connection for ABC phases. The degree of protection is IP40, with a rated current of 60A and a rated voltage (AC) of 600Vac 600Y/347Vac. It offers mechanical durability of 20,000 operations at no load and mounts on I-line with line side isolated plug-on jaws plus a mechanical I-Line bracket mechanism. This 3-pole (3P) circuit breaker has dimensions of 137 mm in height, 89 mm in depth, and 81 mm in width. It falls under utilisation category A and features protection settings for over-current fixed at 60A, short-circuit hold current fixed at 640A, and short-circuit trip current fixed at 960A. The rated voltage (DC) is 250Vdc, with a rated insulation voltage (Ui) of 800 V, and a rated operating voltage (Ue) of 525 V. Protection functions include thermal protection for overload and magnetic protection for short-circuit, with a trip current rating of 60 AT. Its electrical durability with load is 10,000 operations at 440Vac; In, and it has a frame current rating of 100 AF. The operating mode is toggle (manual), and it has a short circuit breaking rating of 25kA at 240Vac, 18kA at 480Vac, 18kA at 480Y/277Vac, 14kA at 600Y/347Vac, and 10kA at 250Vdc, all under UL489. The trip unit type is thermal-magnetic (fixed) with no display.

Schneider Electric

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo