Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

CSP 11-34F2-D-M-ST Schmersal Electronic Components

Schmersal CSP 11-34F2-D-M-ST Safety sensors (Archive); 1 x connector plug M12, 8-pole; Actuation from side; with On-site acknowledgment; NOTICE: Not available! (Replacement: RSS 36 I); Thermoplastic enclosure; Electronic contact-free, coded system; Tampering protection by paired codi
Schmersal

Part#:CSP 11-34F2-D-M-ST

Manufacturer:Schmersal

Alt. Part#:101208005

Product Lifecycle:Discontinued

Get a quick Quote!

Safety sensors (Archive); 1 x connector plug M12, 8-pole; Actuation from side; with On-site acknowledgment; NOTICE: Not available! (Replacement: RSS 36 I); Thermoplastic enclosure; Electronic contact-free, coded system; Tampering protection by paired codi

About the manufacturer: Schmersal is one of the manufacturers that offers Electronic Components that you can order at Quotebeam.com. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Check out the CSP 11-34F2-D-M-ST Schmersal price in the box on the right side or send a quick quote.

Product Details

  • EMC rating
    IEC 61000-6-2
  • Interfering radiation
    IEC 61000-6-4
  • Current, Utilisation category DC12
    0.25 A
  • Voltage, Utilisation category DC13
    24 VDC
  • Versions
    p-type
  • Voltage drop Ud, maximum
    5 V
  • Voltage, Utilisation category DC12
    24 VDC
  • Current leakage Ir
    0.5 mA
  • Output current, (fail-safe output), maximum
    0.25 A
  • Rated operating current (safety outputs)
    250 mA
  • Switching frequency, approx.
    3 Hz
  • Utilisation category DC-13
    24 VDC
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Operating current
    50 mA
  • Rated operating voltage, minimum
    20.4 VDC
  • No-load supply current I0
    100 mA
  • Voltage type
    DC (direct current)
  • Degree of pollution to VDE 0100
    3
  • Overvoltage category
    III
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Ambient temperature, minimum
    -25 °C
  • Resistance to vibrations to EN 60068-2-6
    10 … 55 Hz, amplitude 1 mm
  • Storage and transport temperature, maximum
    +85 °C
  • Note
    The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current
  • Utilisation category DC-12
    24 VDC
  • Rated operating voltage, maximum
    26.4 VDC
  • Rated insulation voltage Ui
    32 VAC/DC
  • Protection rating
    II
  • Storage and transport temperature, minimum
    -25 °C
  • Restistance to shock
    30 g / 11 ms
  • Degree of protection
    IP65 to EN 60529, IP67 to EN 60529
  • Ambient temperature, maximum
    +70 °C
  • Height of sensor
    108.2 mm
  • Length of sensor
    27 mm
  • Width of sensor
    35 mm
  • Switch distance
    11 mm
  • Ensured switch distance OFF Sar
    15 mm
  • Terminal Connector
    Connector plug M12, 8-pole
  • Hysteresis (Switch distance), maximum
    1.5 mm
  • Note (Repeat accuracy R)
    Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 30 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 8 mm.
  • Ensured switch distance ON Sao
    8 mm
  • Repeat accuracy R R
    0.5 mm
  • Actuating panels
    lateral
  • Number of Series-wiring of sensors
    31
  • Number of fail-safe digital outputs
    2
  • Number of LEDs
    3
  • Number of semi-conductor outputs with signaling function
    1
  • On-site acknowledgment
    Yes
  • Integral System Diagnostics, status
    Yes
  • Short circuit detection
    Yes
  • Safety functions
    Yes
  • Duration of risk, maximum
    60 ms
  • Input for enabling pushbutton, suitable for automatic start
    Yes
  • Input for reset pushbutton, with edge monitoring
    Yes
  • Short-circuit recognition
    Yes
  • Cascadable
    Yes
  • Enclosure material
    Glass-fibre, reinforced thermoplastic
  • Diagnostic output
    Yes
  • Standards
    IEC 61508, IEC 60947-5-3, EN ISO 13849-1
  • Reaction time, maximum
    30 ms
  • Sensor topology
    Sensor for series wiring
  • Active area
    lateral
  • Installation conditions (mechanical)
    not flush
  • Housing construction form
    Block
  • Gross weight
    140.5 g
  • Active principle
    inductive

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents CSP 11-34F2-D-M-ST Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schmersal

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schmersal Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schmersal Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schmersal, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo