AZM400Z-ST2-I1-2P2P-T-E Schmersal Safety Switch Interlocks

Schmersal AZM400Z-ST2-I1-2P2P-T-E Solenoid interlocks; Individual coding with RFID technology; Coding level "High" according to ISO 14119; 2 Connector M12, 8- and 5-poles; Guard locking monitored; 2 Diagnostic outputs; Emergency exit; Electric manual release with auxiliary voltage; Bistab
Schmersal

Part#:AZM400Z-ST2-I1-2P2P-T-E

Manufacturer:Schmersal

Alt. Part#:103003835

Product Lifecycle:Active

Get a quick Quote!

Solenoid interlocks; Individual coding with RFID technology; Coding level "High" according to ISO 14119; 2 Connector M12, 8- and 5-poles; Guard locking monitored; 2 Diagnostic outputs; Emergency exit; Electric manual release with auxiliary voltage; Bistab

About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switch Interlocks that you can order at Quotebeam.com. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.

Check out the AZM400Z-ST2-I1-2P2P-T-E Schmersal price in the box on the right side or send a quick quote.

Product Details

  • Note
    The diagnostic output are not safety relevant outputs!
  • Versions
    short-circuit proof, p-type
  • Current, Utilisation category DC13
    0.05 A
  • Voltage, Utilisation category DC13
    24 VDC
  • Current, Utilisation category DC12
    0.05 A
  • Voltage drop Ud, maximum
    2 V
  • Voltage, Utilisation category DC12
    24 VDC
  • Current leakage Ir
    1.5 mA
  • Rated operating current (safety outputs)
    250 mA
  • Allowable discrepancy time (input), maximum
    10 s
  • Classification ZVEI CB24I, Sink
    C1, C2
  • Classification ZVEI CB24I, Source
    C2
  • Switching thresholds of the control inputs
    −3 V … 5 V (Low), 15 V … 30 V (High)
  • Minimal average cycle time (with continuous operation)
    20 s
  • Open / close cycle (Motor), minimum
    3
  • Switching frequency, approx.
    0.3 Hz
  • Required rated short-circuit current to EN 60947-5-1
    100 A
  • Operating current
    50 mA
  • Rated operating voltage
    24 VDC
  • No-load supply current I0
    100 mA
  • Current consumption at 24V, maximum
    15 mA
  • Current consumption at 24V, minimum
    10 mA
  • Current consumption, maximum
    600 mA
  • Operating Current
    100 mA
  • Degree of pollution to VDE 0100
    3
  • Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm
  • Overvoltage category
    III
  • Rated insulation voltage Ui
    32 VDC
  • Rated impulse withstand voltage Uimp
    0.8 kV
  • Protection rating
    III
  • Length of sensor
    65.3 mm
  • Restistance to shock
    30 g / 11 ms
  • Storage and transport temperature, maximum
    +85 °C
  • Storage and transport temperature, minimum
    -40 °C
  • Degree of protection
    IP66 to EN 60529, IP67 to EN 60529
  • Ambient temperature, minimum
    -20 °C
  • Ambient temperature, maximum
    +55 °C
  • Height of sensor
    166.7 mm
  • Note (Lateral force at bolt return)
    Does not apply to emergency exit, Bowden cable and manual release
  • Width of sensor
    77.8 mm
  • Tightening torque of the screw
    8 Nm
  • Terminal Connector
    2 connector M12, 8 and 5 pin
  • Lateral force at bolt return, maximal (against locked door)
    300 N
  • Clamping force, maximum Fmax
    13,000 N
  • Clamping force in accordance with ISO14119 Fzh
    10,000 N
  • Minimum distance devices
    30 mm
  • Active principle
    Magnetic field, RFID
  • Note (Mechanical lifetime)
    Which have a lateral force Ftrans = 100 N: 100.000 operations
  • Mechanical life, minimum
    1,000,000 Operations
  • Standards
    IEC 60947-5-1, EN ISO 13849-1, IEC 61508
  • general information
    Individual coding
  • Interlocking principle
    bistable
  • Number of safety contacts
    2
  • Safety functions
    Yes
  • Reaction time, maximum
    100 ms
  • Number of diagnostic signals
    2
  • Integral System Diagnostics, status
    Yes
  • Electronic manual release
    Yes
  • Short-circuit recognition
    Yes
  • Time to readiness, maximum
    1,500 ms
  • Enclosure material
    Light alloy die-casting
  • Emergency exit
    Yes
  • Short circuit detection
    Yes
  • Guard locking monitored
    Yes
  • Coding level according to ISO 14119
    High
  • Gross weight
    774 g

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging



Related documents AZM400Z-ST2-I1-2P2P-T-E Specs

1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Schmersal

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Schmersal Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schmersal Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schmersal, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo