AZM300Z-I1-ST-1P2P-A-T Schmersal Safety Switch Interlocks
Part#:AZM300Z-I1-ST-1P2P-A-T
Manufacturer:Schmersal
Alt. Part#:103033525
Product Lifecycle:Active
Get a quick Quote!
Solenoid interlocks; Hygienic design; Protection class IP 69; Suitable for mounting to profile systems; Thermoplastic enclosure; RFID-technology for needs-based protection against tampering; 3 different directions of actuation; Compact design; 3 LEDs to s
About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switch Interlocks that you can order at Quotebeam.com. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Check out the AZM300Z-I1-ST-1P2P-A-T Schmersal price in the box on the right side or send a quick quote.
Product Details
- Test pulse interval, typical 1000 ms
- Current, Utilisation category DC13 0.05 A
- Voltage, Utilisation category DC13 24 VDC
- Current, Utilisation category DC12 0.05 A
- Voltage drop Ud, maximum 4 V
- Voltage, Utilisation category DC12 24 VDC
- Current leakage Ir 0.5 mA
- Versions short-circuit proof, p-type
- Test pulse interval, minimum 100 ms
- Classification ZVEI CB24I, Source C2
- Classification ZVEI CB24I, Sink C1, C2
- Test pulse duration, maximum 0.5 ms
- Current consumption at 24V 5 mA
- Duty cycle solenoid 100 %
- Switching thresholds −3 V … 5 V (Low), 15 V … 30 V (High)
- Switching frequency, maximum 0.5 Hz
- External wiring and device fuse rating 2 A gG
- Current consumption with solenoid ON, peak 350 mA / 200 ms
- Required rated short-circuit current to EN 60947-5-1 100 A
- Current consumption with solenoid ON, average 200 mA
- No-load supply current I0 100 mA
- Notes (Power supply, general) stabilised PELV power supply
- Operating voltage, minimum 20.4 VDC
- Operating voltage, maximum 26.4 VDC
- Overvoltage category III
- Rated impulse withstand voltage Uimp 0.8 kV
- Degree of pollution to IEC/EN 60664-1 3
- Zulässige Aufstellhöhe über NN, maximum 2,000 m
- Protection rating III
- Rated insulation voltage Ui 32 VDC
- Note (Relative humidity) non-condensing, non-icing
- Restistance to shock 30 g / 11 ms
- Resistance to vibrations to EN 60068-2-6 10 … 150 Hz, amplitude 0.35 mm
- Relative humidity, maximum 93 %
- Storage and transport temperature, maximum +90 °C
- Storage and transport temperature, minimum -10 °C
- Degree of protection IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
- Ambient temperature, maximum +60 °C
- Length of sensor 146 mm
- Height of sensor 55 mm
- Ambient temperature, minimum +0 °C
- Width of sensor 87.5 mm
- Note (series connection of the sensors) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
- Length of sensor chain, maximum 200 m
- Terminal Connector Connector M12, 8-pole, A-coded
- Ensured switch distance ON Sao 1 mm
- Ensured switch distance OFF Sar 20 mm
- Switch distance 2 mm
- Tightening torque of the fixing screws, minimum 6 Nm
- Clamping force, maximum Fmax 1,500 N
- Type of the fixing screws 2x M6
- Latching force, adjustable, position 1 25 N
- Tightening torque for the fixing screws, maximum 7 Nm
- Latching force, adjustable, position 2 50 N
- Angular offset between interlocking device and actuator, maximum 2 °
- Clamping force in accordance with ISO14119 Fzh 1,150 N
- Note (Mechanical lifetime) When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
- Number of fail-safe digital outputs 2
- Short-circuit recognition Yes
- Mechanical life, minimum 1,000,000 Operations
- Safety functions Yes
- Series-wiring Yes
- Integral System Diagnostics, status Yes
- Enclosure material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- general information Individual coding
- Short circuit detection Yes
- Active principle RFID
- Guard locking monitored Yes
- Emergency exit Yes
- Standards EN ISO 13849-1, EN ISO 14119, IEC 60947-5-3
- Response time safety outputs in case of switch-off by safety inputs, maximum 1.5 ms
- Latching Yes
- Power to lock Yes
- Response time safety outputs in case of switch-off by actuator, maximum 100 ms
- Time to readiness, maximum 5,000 ms
- Frequency band RFID 125 kHz
- Coding level according to ISO 14119 High
- Gross weight 639.5 g
- Duration of risk, maximum 200 ms
- Transmit power, maximum -6 dB/m
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
Related documents AZM300Z-I1-ST-1P2P-A-T Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Schmersal
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Schmersal Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schmersal Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schmersal, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨