AZM300B-I2-ST-SD2P-A Schmersal - Solenoid interlocks; Repeated individual coding with RFID technology; Coding level "High" according to ISO 14119; Connector M12, 8-pole; Power to lock; Actuator monitored; serial diagnostic output; Hygienic design; Protection class IP 69; Suitable for mou
About the manufacturer: Schmersal is one of the manufacturers that offers Safety Switches that you can order at Quotebeam.com. Schmersal produces a wide range of high-quality switchgears specifically engineered to protect machinery and facilities in industrial automation and the elevator industry.
Check out the AZM300B-I2-ST-SD2P-A Schmersal price in the box on the right side or send a quick quote.
Product Details
- Storage and transport temperature, minimum -10 °C
- Degree of protection IP66 to EN 60529, IP67 to EN 60529, IP69 to EN 60529
- Terminal Connector Connector M12, 8-pole, A-coded
- Latching force, adjustable, position 1 25 N
- Clamping force in accordance with ISO14119 Fzh 1,150 N
- Note (Mechanical lifetime) When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)
- Manual release Yes
- Actuator monitored Yes
- Time to readiness, maximum 5,000 ms
- Enclosure material Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Wiring capacity 50 nF
- Operation current 150 mA
- Voltage drop Ud, maximum 4 V
- Current, Utilisation category DC13 0.05 A
- Test pulse interval, typical 1000 ms
- Current, Utilisation category DC12 0.05 A
- Voltage, Utilisation category DC13 24 VDC
- Voltage, Utilisation category DC12 24 VDC
- Current leakage Ir 0.5 mA
- Versions short-circuit proof, p-type
- Current consumption at 24V 5 mA
- Classification ZVEI CB24I, Source C2
- Classification ZVEI CB24I, Sink C1, C2
- Test pulse interval, minimum 100 ms
- Duty cycle solenoid 100 %
- Test pulse duration, maximum 0.5 ms
- Switching thresholds −3 V … 5 V (Low), 15 V … 30 V (High)
- External wiring and device fuse rating 2 A gG
- Required rated short-circuit current to EN 60947-5-1 100 A
- Switching frequency, maximum 0.5 Hz
- Current consumption with solenoid ON, peak 350 mA / 200 ms
- Current consumption with solenoid ON, average 200 mA
- No-load supply current I0 100 mA
- Operating voltage, maximum 26.4 VDC
- Notes (Power supply, general) stabilised PELV power supply
- Operating voltage, minimum 20.4 VDC
- Overvoltage category III
- Rated insulation voltage Ui 32 VDC
- Rated impulse withstand voltage Uimp 0.8 kV
- Zulässige Aufstellhöhe über NN, maximum 2,000 m
- Degree of pollution to IEC/EN 60664-1 3
- Protection rating III
- Restistance to shock 30 g / 11 ms
- Resistance to vibrations to EN 60068-2-6 10 … 150 Hz, amplitude 0.35 mm
- Note (Relative humidity) non-condensing, non-icing
- Relative humidity, maximum 93 %
- Ambient temperature, minimum +0 °C
- Ambient temperature, maximum +60 °C
- Storage and transport temperature, maximum +90 °C
- Length of sensor 120 mm
- Width of sensor 87.5 mm
- Height of sensor 35 mm
- Note (series connection of the sensors) Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Length of sensor chain, maximum 200 m
- Switch distance 2 mm
- Note (length of the sensor chain) Cable length and cross-section change the voltage drop dependiing on the output current
- Ensured switch distance OFF Sar 20 mm
- Ensured switch distance ON Sao 1 mm
- Clamping force, maximum Fmax 1,500 N
- Type of the fixing screws 2x M6
- Tightening torque for the fixing screws, maximum 7 Nm
- Latching force, adjustable, position 2 50 N
- Tightening torque of the fixing screws, minimum 6 Nm
- Angular offset between interlocking device and actuator, maximum 2 °
- Short circuit detection Yes
- Safety functions Yes
- Number of fail-safe digital outputs 2
- Series-wiring Yes
- Mechanical life, minimum 1,000,000 Operations
- Integral System Diagnostics, status Yes
- Latching Yes
- Short-circuit recognition Yes
- Power to lock Yes
- Response time safety outputs in case of switch-off by actuator, maximum 100 ms
- Serial diagnostics Yes
- Response time safety outputs in case of switch-off by safety inputs, maximum 1.5 ms
- Duration of risk, maximum 200 ms
- Transmit power, maximum -6 dB/m
- Frequency band RFID 125 kHz
- general information Individual coding, multiple teaching
- Gross weight 610 g
- Standards IEC 61508, IEC 60947-5-3, EN ISO 13849-1
- Coding level according to ISO 14119 High
- Active principle RFID
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
AZM300B-I2-ST-SD2P-A Description
AZM300B-I2-ST-SD2P-A Schmersal - Solenoid interlocks; Repeated individual coding with RFID technology; Coding level "High" according to ISO 14119; Connector M12, 8-pole; Power to lock; Actuator monitored; serial diagnostic output; Hygienic design; Protection class IP 69; Suitable for mou
Related documents AZM300B-I2-ST-SD2P-A Specs
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Schmersal
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Schmersal Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Schmersal Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Schmersal, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨