PISA11.CLASS2 Puls Protection Modules (DC)

Puls PISA11.CLASS2 PULS PISA11.CLASS2 is a protection unit designed for DIN rail mounting, featuring a 4-channel protection module with 1 input and 4 outputs. It operates within an ambient air temperature range of -25 to +70°C and adheres to NEC Class 2 design standards. The rated current is 16A, distributed as 4A per channel, with a derating to 0.025A/+60°C to +70°C for each channel. It utilizes screw-clamp connections for secure installation and is part of the PISA11-series. The dimensions are W45mm x H75mm x D91mm, and it requires a supply voltage of 18Vdc to 30Vdc, with 24Vdc being typical and 21.4Vdc needed to turn on the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with a 10ms shutdown time and current limitation with an adjustable threshold between 16.6A and 23.6A. Power dissipation at full output load with a 24V input is 1.8W, and the processing time for the turn-on delay of output is 270ms. The voltage drop across the unit is 101mV / 0.101 V. Electrical durability is rated at 216,000 hours at 40°C with a 4x2A output and 610,000 hours at 25°C with a 4x2A output.
Puls

Part#:PISA11.CLASS2

Manufacturer:Puls

Product Lifecycle:Active

In-stock parts: 12

Nov 21, 2024

PULS PISA11.CLASS2 is a protection unit designed for DIN rail mounting, featuring a 4-channel protection module with 1 input and 4 outputs. It operates within an ambient air temperature range of -25 to +70°C and adheres to NEC Class 2 design standards. The rated current is 16A, distributed as 4A per channel, with a derating to 0.025A/+60°C to +70°C for each channel. It utilizes screw-clamp connections for secure installation and is part of the PISA11-series. The dimensions are W45mm x H75mm x D91mm, and it requires a supply voltage of 18Vdc to 30Vdc, with 24Vdc being typical and 21.4Vdc needed to turn on the outputs. The output voltage is adjustable between 24Vdc and 28Vdc. Protection functions include short-circuit protection with a 10ms shutdown time and current limitation with an adjustable threshold between 16.6A and 23.6A. Power dissipation at full output load with a 24V input is 1.8W, and the processing time for the turn-on delay of output is 270ms. The voltage drop across the unit is 101mV / 0.101 V. Electrical durability is rated at 216,000 hours at 40°C with a 4x2A output and 610,000 hours at 25°C with a 4x2A output.

About the manufacturer: Puls is one of the manufacturers that offers Protection Modules (DC) that you can order at Quotebeam.com. Puls specializes in AC/DC power supplies, dedicating its efforts solely to the development of premium DIN rail power supplies. As a leading authority in power conversion, Puls distinguishes itself through focused engineering and an unwavering commitment to quality, positioning itself as the top leader in the field. This dedication ensures the highest standard in the industry, reflecting in every product they offer.

Check out the PISA11.CLASS2 Puls price in the box on the right side or send a quick quote.

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


This item can ship within 5 days!

1-year warranty

$144.69

Stock:

12

Select Qty:

$144.69

$144.69 each

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Puls

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Puls Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Puls Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Puls, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

This item can ship within 5 days!

YRM2.DIODE Part Image. Manufactured by Puls.

YRM2.DIODE

$157.85

Verified stock: 12

PULS YRM2.DIODE is a redundancy unit belonging to the Y-series, designed with diode technology and ATEX approval for enhanced safety in potentially explosive atmospheres. This dual-input redundancy module supports 2 x inputs and 1 x output, operating within a supply voltage range of 18Vdc-60Vdc, including nominal values of 24Vdc, 48Vdc, and 60Vdc. It features screw-clamp connections for secure installation and is designed for DIN rail mounting, ensuring compatibility with standard industrial setups. The unit is capable of handling a rated current of 20A at 48Vdc, with a derating to 0.5A in temperatures ranging from +60°C to +70°C. It can withstand ambient air temperatures for operation between -40°C and +70°C. The YRM2.DIODE measures 32mm in width, 124mm in height, and 117mm in depth, with a peak inrush current consumption of 150A at 18-60Vdc input. It includes protection functions against short-circuits, with a 25A threshold at 6V, and supports both series/parallel operation for 1+1 redundancy and N+1 redundancy, ensuring continuous operation by using multiple power supplies in parallel. The output voltage range is 24-48Vdc, with nominal values of 24Vdc and 48Vdc. Power dissipation/losses are rated at 8.8W for 18-60Vdc input with 2x5A input and 9.5W for a 10A input. The electrical durability of the unit is estimated at 25 years or 219,000 hours at both 40°C with a 20A output and 25°C with a 10A output. Lastly, the ripple is specified at 780mVpp over a frequency range of 20Hz to 20MHz at 50Ω.

Puls

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo