Marshalling patchboard, without actuation lever, nom. voltage: 500 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 1, number of connections: 6, width: 11 mm, length:
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3270446 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Internal cylindrical gage A1
- Min. AWG conductor cross section, flexible 26
- Connection cross sections directly pluggable 0.34 mm² 2.5 mm² 20 14
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm²
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- UNSPSC 18.0 39121410
- Conductor cross section flexible min. 0.14 mm²
- ECLASS 9.0 27141120
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- ECLASS 10.0.1 27141120
- ECLASS 4.1 27141100
- Ambient temperature (assembly) -5 °C ... 70 °C
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 6.0 27141100
- ETIM 7.0 EC000897
- ECLASS 4.0 27141100
- UNSPSC 20.0 39121410
- ETIM 6.0 EC000897
- ECLASS 5.1 27141100
- Nominal cross section 1.5 mm²
- Color of connection elements orange
- Rated surge voltage 6 kV
- Maximum power dissipation for nominal condition 0.56 W
- Result of surge voltage test Test passed
- Result of power-frequency withstand voltage test Test passed
- Note The max. load current must not be exceeded by the total current of all connected conductors.
- Result of temperature-rise test Test passed
- Result of aging test Test passed
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 12.2 mm
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Color gray
- Overvoltage category III
- Nominal voltage UN 500 V
- Open side panel No
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Bending test turns 135
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Result of thermal test Test passed
- Short-time current 0.3 kA
- Test spectrum Service life test category 1, class B, body mounted
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Conductor cross section solid min. 0.34 mm²
- Number of levels 1
- Flammability rating according to UL 94 V0
- Setpoint 1 N
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Ageing test for screwless modular terminal block temperature cycles 192
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Shock form Half-sine
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Maximum load current 24 A (in case of a 2.5 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Bending test rotation speed 10 rpm
- Tight fit on carrier NS 35
- Conductor cross section AWG min. 26
- Max. AWG conductor cross section, flexible 14
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- ECLASS 5.0 27141100
- Oscillation, broadband noise test result Test passed
- ASD level 0.964 (m/s2)2/Hz
- Shock test result Test passed
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Height 30 mm
- Connection in acc. with standard IEC 60947-7-1
- Number of connections 6
- Insulating material PA
- Insulating material group I
- Finger protection guaranteed
- Result of flexion and pull-out test Test passed
- Tensile test result Test passed
- Result of voltage-drop test Test passed
- Conductor cross section short circuit testing 2.5 mm²
- Degree of pollution 3
- Nominal current IN 17.5 A
- Shock duration 30 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Width 11 mm
- Stripping length 8 mm ... 10 mm
- Conductor cross section AWG max. 14
- Back of the hand protection guaranteed
- Power frequency withstand voltage setpoint 1.89 kV
- Result of tight fit on support Test passed
- Short circuit stability result Test passed
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 5g
- Test duration per axis 5 h
- Number of positions 1
- ECLASS 11.0 27141120
- ECLASS 7.0 27141120
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- Ambient temperature (actuation) -5 °C ... 70 °C
- UNSPSC 19.0 39121410
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨