Phoenix Contact 3270426 Marshalling patchboard, nom. voltage: 500 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 1, number of connections: 6, width: 11 mm, length: 12.2 mm, color: gray, col
Phoenix Contact

Part#:3270426

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Marshalling patchboard, nom. voltage: 500 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 1, number of connections: 6, width: 11 mm, length: 12.2 mm, color: gray, col

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3270426 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of connections
    6
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Maximum power dissipation for nominal condition
    0.56 W
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Setpoint
    1 N
  • Connection in acc. with standard
    IEC 60947-7-1
  • Rated surge voltage
    6 kV
  • Overvoltage category
    III
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Bending test rotation speed
    10 rpm
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Number of positions
    1
  • Color of connection elements
    orange
  • Result of temperature-rise test
    Test passed
  • Result of tight fit on support
    Test passed
  • Result of thermal test
    Test passed
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible max.
    1.5 mm²
  • Internal cylindrical gage
    A1
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 11.0
    27141120
  • ECLASS 7.0
    27141120
  • ECLASS 9.0
    27141120
  • ETIM 7.0
    EC000897
  • Result of surge voltage test
    Test passed
  • ECLASS 6.0
    27141100
  • ECLASS 4.0
    27141100
  • UNSPSC 13.2
    39121410
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Conductor cross section flexible min.
    0.14 mm²
  • Max. AWG conductor cross section, flexible
    14
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm² 20 14
  • ECLASS 10.0.1
    27141120
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 4.1
    27141100
  • ECLASS 5.1
    27141100
  • ETIM 6.0
    EC000897
  • UNSPSC 20.0
    39121410
  • UNSPSC 19.0
    39121410
  • Conductor cross section AWG max.
    14
  • Min. AWG conductor cross section, flexible
    26
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Degree of pollution
    3
  • Insulating material
    PA
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Tight fit on carrier
    NS 35
  • Number of levels
    1
  • Color
    gray
  • Insulating material group
    I
  • Finger protection
    guaranteed
  • Open side panel
    No
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Result of voltage-drop test
    Test passed
  • ASD level
    0.964 (m/s2)2/Hz
  • Static insulating material application in cold
    -60 °C
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Stripping length
    8 mm ... 10 mm
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Oscillation, broadband noise test result
    Test passed
  • Nominal current IN
    17.5 A
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Short-time current
    0.3 kA
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Shock test result
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    11 mm
  • Short circuit stability result
    Test passed
  • Test duration per axis
    5 h
  • Shock duration
    30 ms
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Flammability rating according to UL 94
    V0
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Length
    12.2 mm
  • Nominal cross section
    1.5 mm²
  • Maximum load current
    24 A (in case of a 2.5 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
  • Nominal voltage UN
    500 V
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Height
    30 mm
  • Shock form
    Half-sine
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Back of the hand protection
    guaranteed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Bending test turns
    135
  • Conductor cross section short circuit testing
    2.5 mm²
  • Test spectrum
    Service life test category 1, class B, body mounted
  • Acceleration
    5g
  • Connection method
    Push-in connection
  • Result of aging test
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo