3270318 Phoenix Contact Terminal Blocks
Part#:3270318
Manufacturer:Phoenix Contact
Product Lifecycle:Active
Get a quick Quote!
Marshalling patchboard, nom. voltage: 500 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 48, number of connections: 288, width: 66 mm, length: 102 mm, color: gray, c
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3270318 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Setpoint 1 N
- Short-time current 0.3 kA
- Conductor cross section solid min. 0.34 mm²
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- Acceleration 5g
- ASD level 0.964 (m/s2)2/Hz
- Shock duration 30 ms
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Width 66 mm
- Conductor cross section AWG min. 26
- Stripping length 8 mm ... 10 mm
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.34 mm²
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Number of shocks per direction 3
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height 30 mm
- Connection in acc. with standard IEC 60947-7-1
- Static insulating material application in cold -60 °C
- Surface flammability NFPA 130 (ASTM E 162) passed
- Length 102 mm
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 10.0.1 27141120
- ECLASS 5.1 27141100
- ECLASS 6.0 27141100
- UNSPSC 21.0 39121410
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.1 27141100
- UNSPSC 18.0 39121410
- Conductor cross section AWG max. 14
- Min. AWG conductor cross section, flexible 26
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 5.0 27141100
- UNSPSC 13.2 39121410
- UNSPSC 20.0 39121410
- Conductor cross section flexible min. 0.14 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 4.0 27141100
- UNSPSC 19.0 39121410
- Connection cross sections directly pluggable 0.34 mm² 2.5 mm² 20 14
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ETIM 6.0 EC000897
- ETIM 7.0 EC000897
- Number of levels 1
- Color gray
- Insulating material PA
- Maximum power dissipation for nominal condition 0.56 W (the value is based on one connection block and is multiplied according to the pin assignment)
- Back of the hand protection guaranteed
- Bending test rotation speed 10 rpm
- Result of temperature-rise test Test passed
- Tight fit on carrier NS 35
- Open side panel No
- Result of tight fit on support Test passed
- Number of positions 48
- Result of thermal test Test passed
- Result of aging test Test passed
- Test spectrum Service life test category 1, class B, body mounted
- Color of connection elements gray/white
- Insulating material group I
- Nominal voltage UN 500 V
- Result of power-frequency withstand voltage test Test passed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of flexion and pull-out test Test passed
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- ECLASS 9.0 27141120
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.34 mm²
- Max. AWG conductor cross section, flexible 14
- Internal cylindrical gage A1
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 7.0 27141120
- Note The max. load current must not be exceeded by the total current of all connected conductors.
- Nominal cross section 1.5 mm²
- Degree of pollution 3
- Overvoltage category III
- Rated surge voltage 6 kV
- Maximum load current 24 A (in case of a 2.5 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
- Result of surge voltage test Test passed
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Tensile test result Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Result of voltage-drop test Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Oscillation, broadband noise test result Test passed
- Shock test result Test passed
- Test duration per axis 5 h
- Shock form Half-sine
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Number of connections 288
- Flammability rating according to UL 94 V0
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Nominal current IN 17.5 A
- Finger protection guaranteed
- Bending test turns 135
- Power frequency withstand voltage setpoint 1.89 kV
- Short circuit stability result Test passed
- Conductor cross section short circuit testing 2.5 mm²
- Ageing test for screwless modular terminal block temperature cycles 192
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Test directions X-, Y- and Z-axis (pos. and neg.)
Product condition
ORIGINAL PACKAGING
SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging
1-year warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
By purchasing this item, you agree to the Terms & Conditions
Quotebeam is NOT an authorized distributor of Phoenix Contact
Shipping and Delivery Worldwide
calculate costs and time
Secure Payment Processing
with money back guarantee
1 year warranty
on all parts
Responsive Customer Support
we're here to help!
Need more details?
Feel free to chat with us or check our FAQ
Phoenix Contact Disclaimer:
The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Relevant products
Do you have questions?
We’re here for you ✨