Bryan Obida

We are online

Monday - Friday 6AM - 6PM PST

3270181 Phoenix Contact Terminal Blocks

Phoenix Contact 3270181 Potential distributors, without actuation lever, nom. voltage: 250 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 2, number of connections: 16, width: 8.3 mm, length
Phoenix Contact

Part#:3270181

Manufacturer:Phoenix Contact

Product Lifecycle:Active

Get a quick Quote!

Potential distributors, without actuation lever, nom. voltage: 250 V, nominal current: 17.5 A, cross section: 0.14 mm² - 2.5 mm², AWG: 14 - 26, connection method: Push-in connection, number of positions: 2, number of connections: 16, width: 8.3 mm, length

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Quotebeam.com. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3270181 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ECLASS 4.1
    27141100
  • Flammability rating according to UL 94
    V0
  • Short-time current
    0.3 kA
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Height NS 35/7,5
    55.5 mm
  • Height NS 35/15
    63 mm
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock form
    Half-sine
  • Length
    64 mm
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section flexible max.
    1.5 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    27141100
  • Open side panel
    Yes
  • Tensile test result
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Max. AWG conductor cross section, flexible
    14
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.0
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • ETIM 7.0
    EC000897
  • UNSPSC 13.2
    39121410
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    1.5 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.1
    27141100
  • UNSPSC 19.0
    39121410
  • Connection method
    Push-in connection
  • Conductor cross section flexible min.
    0.14 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ETIM 4.0
    EC000897
  • UNSPSC 20.0
    39121410
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • UNSPSC 6.01
    30211811
  • ETIM 3.0
    EC000897
  • UNSPSC 21.0
    39121410
  • Bending test turns
    135
  • Result of voltage-drop test
    Test passed
  • Setpoint
    1 N
  • Result of thermal test
    Test passed
  • Shock duration
    18 ms
  • Rated surge voltage
    4 kV
  • Nominal voltage UN
    250 V
  • Result of surge voltage test
    Test passed
  • Insulating material group
    I
  • Tight fit on carrier
    NS 35
  • Result of temperature-rise test
    Test passed
  • Short circuit stability result
    Test passed
  • Result of aging test
    Test passed
  • Test duration per axis
    5 h
  • Shock test result
    Test passed
  • Nominal current IN
    17.5 A
  • Result of power-frequency withstand voltage test
    Test passed
  • Back of the hand protection
    guaranteed
  • Insulating material
    PA
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.5 kV
  • Result of flexion and pull-out test
    Test passed
  • Result of tight fit on support
    Test passed
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Conductor cross section short circuit testing
    2.5 mm²
  • Acceleration
    30g
  • Number of positions
    2
  • Color
    blue
  • Finger protection
    guaranteed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Potentials
    1
  • Bending test rotation speed
    10 rpm
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Width
    8.3 mm
  • Number of connections
    16
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Stripping length
    8 mm ... 10 mm
  • Min. AWG conductor cross section, flexible
    26
  • Nominal cross section
    1.5 mm²
  • Overvoltage category
    III
  • Maximum load current
    20 A (in case of a 2.5 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section AWG min.
    26
  • Number of levels
    4
  • Color of connection elements
    black
  • Maximum power dissipation for nominal condition
    0.56 W (the value is multiplied when connecting multiple levels)
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Connection
    1st, 2nd, 3rd and 4th level
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section AWG max.
    14
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    1.5 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 2.5 mm² 20 14
  • ECLASS 11.0
    27141120
  • ECLASS 10.0.1
    27141120
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410

Product condition

ORIGINAL PACKAGING

SURPLUS ORIGINAL PACKAGING - 100% unused and in original packaging


1-year warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

By purchasing this item, you agree to the Terms & Conditions

Quotebeam is NOT an authorized distributor of Phoenix Contact

Shipping and Delivery Worldwide

calculate costs and time


Secure Payment Processing

with money back guarantee


1 year warranty

on all parts


Responsive Customer Support

we're here to help!

Need more details?

Feel free to chat with us or check our FAQ

Phoenix Contact Disclaimer:

The product is unused surplus. Quotebeam is not an authorized surplus dealer or affiliate for the Manufacturer of this product. Products may feature older date codes or be from an earlier series than what is currently available from the manufacturer or authorized dealers. Because Quotebeam is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Phoenix Contact Controls products will have firmware already installed, Quotebeam makes no representation as to whether a Controls product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Quotebeam also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Phoenix Contact, its distributors, or any other source. Quotebeam also makes no representations as to your right to install any such firmware on the product. Quotebeam will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.

Relevant products

Do you have questions?

We’re here for you ✨

We are a proud member of:

Association for High Technology Distribution LogoAssociation for Advancing Automation LogoThe International Society of Automation Logo